56 resultados para Acoustic measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments to investigate the transition process in hypervelocity boundary layers were performed in the T4 free-piston shock tunnel. An array of thin-film heat-transfer gauges was used to detect the location and extent of the transitional region on a 1500 mm long x 120 turn wide flat plate, which formed one of the walls of a duct. The experiments were performed in a Mach 6 flow of air with 6- and 12-MJ/kg nozzle-supply enthalpies at unit Reynolds numbers ranging from 1.6 x 10(6) to 4.9 x 10(6) m(-1). The results show that the characteristics typical of transition taking place through the initiation, growth, and merger of turbulent spots are evident in the heat-transfer signals. A 2-mm-high excrescence located 440 turn from the leading edge was found to be capable of generating a turbulent wedge within an otherwise laminar boundary layer at a unit Reynolds number of 2.6 x 10(6) m(-1) at the 6-MJ/kg condition. A tripping strip, located 100 mm from the leading edge and consisting of a line 37 teeth of 2 rum height equally spaced and spanning the test surface, was also found to be capable of advancing the transition location at the same condition and at the higher enthalpy condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite growing clinical use, cervical auscultation suffers from a lack of research-based data. One of the strongest criticisms of cervical auscultation is that there has been little research to demonstrate how dysphagic swallowing sounds are different from normal swallowing sounds, In order to answer this question, however, one first needs to document the acoustic characteristics of normal, nondysphagic swallowing sounds, This article provides the first normative database of normal swallowing sounds for the adult population. The current investigation documents the acoustic characteristics of normal swallowing sounds for individuals from 18 to more than 60 years of age over a range of thin liquid volumes. Previous research has shown the normal swallow to be a dynamic event. The normal swallow is sensitive to aging of the oropharyngeal system, and also to the volume of bolus swallowed. The current investigation found that the acoustic signals generated during swallowing were sensitive to an individual's age and to the volume of the bolus swallowed. There were also some gender-specific differences in the acoustic profile of the swallowing sound, It is anticipated that the results will provide a catalyst for further research into cervical auscultation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The range of variability between individuals of the same chronological age (CA) in somatic and biological maturity is large and especially accentuated around the adolescent growth spurt. Maturity assessment is an important consideration when dealing with adolescents, from both a research perspective and youth sports stratification. A noninvasive, practical method predicting years from peak height velocity (a maturity offset value) by using anthropometric variables is developed in one sample and cross-validated in two different samples. Methods: Gender specific multiple regression equations were calculated on a sample of 152 Canadian children aged 8-16 yr (79 boys; 73 girls) who were followed through adolescence from 1991 to 1997, The equations included three somatic dimensions (height, sitting height, and leg length), CA, and their interactions. The equations were cross-validated on a Combined sample of Canadian (71 boys, 40 girls measured from 1964 through 1973) and Flemish children (50 boys, 48 girls measured from 1985 through 1999). Results: The coefficient of determination (R2) for the boys' model was 0.92 and for the girls' model 0.91 the SEEs were 0.49 and 0.50, respectively, Mean difference between actual and predicted maturity offset for the verification samples was 0.24 (SD 0.65) yr in boys and 0,001 (SD 0.68) yr in girls. Conclusion: Although the cross-validation meets statistical standards or acceptance, caution 1, warranted with regard to implementation. It is recommended that maturity offset be considered as a categorical rather than a continuous assessment. Nevertheless, the equations presented are a reliable, noninvasive and a practical solution for the measure of biological maturity for matching adolescent athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a software application to enable interactive rehabilitation via the Internet. The reliability of the telemedicine application was examined by comparing it with face-to-face assessment. The physical outcome measures assessed were knee range of motion, quadriceps muscle strength, limb girth and an assessment of gait. One therapist performed both in-person and Internet-based measurements of all outcome measures on 20 normal subjects. There was good agreement between the two techniques (the 95% limits of agreement included zero for all the variables studied). Internet assessments were conducted at two bandwidths: ISDN at 128 kbit/s and the telephone network at 17 kbit/s. Bandwidth had no significant influence on any of the measures. This study suggests that Internet-based physiotherapy interventions delivered to the home are suitable for further development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compression amplification significantly alters the acoustic speech signal in comparison to linear amplification. The central hypothesis of the present study was that the compression settings of a two-channel aid that best preserved the acoustic properties of speech compared to linear amplification would yield the best perceptual results, and that the compression settings that most altered the acoustic properties of speech compared to linear would yield significantly poorer speech perception. On the basis of initial acoustic analysis of the test stimuli recorded through a hearing aid, two different compression amplification settings were chosen for the perceptual study. Participants were 74 adults with mild to moderate sensorineural hearing impairment. Overall, the speech perception results supported the hypothesis. A further aim of the study was to determine if variation in participants' speech perception with compression amplification (compared to linear amplification) could be explained by the individual characteristics of age, degree of loss, dynamic range, temporal resolution, and frequency selectivity; however, no significant relationships were found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hot-wire anemometers at low operating currents are used as fast response resistance thermometers for the study of heated turbulent flows. Simultaneous measurement of temperature and velocity is generally performed with multi-wire arrays. In order to give good spatial resolution a new layout has been tested which uses an inclined temperature wire positioned parallel to the nearest inclined velocity wire. This leads to an asymmetric wire arrangement relative to the mean flow direction. As expected, a reduction in thermal interference from the velocity wires results when compared with an array containing a temperature wire placed normal to the flow. However, measurement of higher order moments of fluctuating quantities in an axisymmetric jet shows considerable distortion of radial distributions which is traced to alteration of the temperature field sensed by the temperature wire. When inclined velocity sensitive wires contain a temperature component, the latter may be affected by the same phenomenon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detection of a circumferential crack in a hollow section beam is investigated using coupled response measurements. The crack section is represented by a local flexibility matrix connecting two undamaged beam segments. This matrix defines the relationship between the displacements and forces across the crack section and is derived by applying fundamental fracture mechanics theory. The suitability of the mode coupling methodology is first demonstrated analytically. Laboratory test results are then presented for circular hollow section beams with artificially generated cracks of varying severity. It is shown that this method has the potential as a damage detection tool for mechanical structures. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skin-friction measurements are reported for high-enthalpy and high-Mach-number laminar, transitional and turbulent boundary layers. The measurements were performed in a free-piston shock tunnel with air-flow Mach number, stagnation enthalpy and Reynolds numbers in the ranges of 4.4-6.7, 3-13 MJ kg(-1) and 0.16 x 10(6)-21 x 10(6), respectively. Wall temperatures were near 300 K and this resulted in ratios of wall enthalpy to flow-stagnation enthalpy in the range of 0.1-0.02. The experiments were performed using rectangular ducts. The measurements were accomplished using a new skin-friction gauge that was developed for impulse facility testing. The gauge was an acceleration compensated piezoelectric transducer and had a lowest natural frequency near 40 kHz. Turbulent skin-friction levels were measured to within a typical uncertainty of +/-7%. The systematic uncertainty in measured skin-friction coefficient was high for the tested laminar conditions; however, to within experimental uncertainty, the skin-friction and heat-transfer measurements were in agreement with the laminar theory of van Driest (1952). For predicting turbulent skin-friction coefficient, it was established that, for the range of Mach numbers and Reynolds numbers of the experiments, with cold walls and boundary layers approaching the turbulent equilibrium state, the Spalding & Chi (1964) method was the most suitable of the theories tested. It was also established that if the heat transfer rate to the wall is to be predicted, then the Spalding & Chi (1964) method should be used in conjunction with a Reynolds analogy factor near unity. If more accurate results are required, then an experimentally observed relationship between the Reynolds analogy factor and the skin-friction coefficient may be applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a review of the time-domain polarization measurement techniques for the condition assessment of aged transformer insulation. The polarization process is first described with appropriate dielectric response theories and then commonly used polarization methods are described with special emphasis on the most widely used return voltage(rv) measurement. Most recent emphasis has been directed to techniques of determining moisture content of insulation indirectly by measuring rv parameters. The major difficulty still lies with the accurate interpretation of return voltage results. This paper investigates different thoughts regarding the interpretation of rv results for different moisture and ageing conditions. Other time domain polarization measurement techniques and their results are also presented in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aims: Hip fracture is a devastating event in terms of outcome in the elderly, and the best predictor of hip fracture risk is hip bone density, usually measured by dual X-ray absorptiometry (DXA). However, bone density can also be ascertained from computerized tomography (CT) scans, and mid-thigh scans are frequently employed to assess the muscle and fat composition of the lower limb. Therefore, we examined if it was possible to predict hip bone density using mid-femoral bone density. Methods: Subjects were 803 ambulatory white and black women and men, aged 70-79 years, participating in the Health, Aging and Body Composition (Health ABC) Study. Bone mineral content (BMC, g) and volumetric bone mineral density (vBMD, mg/cm(3)) of the mid-femur were obtained by CT, whereas BMC and areal bone mineral density (aBMD, g/cm(2)) of the hip (femoral neck and trochanter) were derived from DXA. Results: In regression analyses stratified by race and sex, the coefficient of determination was low with mid-femoral BMC, explaining 6-27% of the variance in hip BMC, with a standard error of estimate (SEE) ranging from 16 to 22% of the mean. For mid-femur vBMD, the variance explained in hip aBMD was 2-17% with a SEE ranging from 15 to 18%. Adjusting aBMD to approximate volumetric density did not improve the relationships. In addition, the utility of fracture prediction was examined. Forty-eight subjects had one or more fractures (various sites) during a mean follow-up of 4.07 years. In logistic regression analysis, there was no association between mid-femoral vBMD and fracture (all fractures), whereas a 1 SD increase in hip BMD was associated with reduced odds for fracture of similar to60%. Conclusions: These results do not support the use of CT-derived mid-femoral vBMD or BMC to predict DXA-measured hip bone mineral status, irrespective of race or sex in older adults. Further, in contrast to femoral neck and trochanter BMD, mid-femur vBMD was not able to predict fracture (all fractures). (C) 2003, Editrice Kurtis.