55 resultados para paw edema test
Resumo:
A migration of Helicoverpa punctigera (Wallengren), Heliothis punctifera (Walker) and Agrotis munda Walker was tracked from Cameron Corner (29degrees00'S, 141degrees00'E) in inland Australia to the Wilcannia region, approximately 400 km to the south-east. A relatively isolated source population was located using a distribution model to predict winter breeding, and confirmed by surveys using sweep netting for larvae. When a synoptic weather pattern likely to produce suitable conditions for migration developed, moths were trapped in the source region. The next morning a simulation model of migration using wind-field data generated by a numerical weather-prediction model was run. Surveys using sweep netting for larvae, trapping and flush counts were then conducted in and around the predicted moth fallout area, approximately 400 km to the south-east. Pollen carried on the probosces of moths caught in this area was compared with that on moths caught in the source area. The survey data and pollen comparisons provided evidence that migration had occurred, and that the migration model gave accurate estimation of the fallout region. The ecological and economic implications of such migrations are discussed.
Resumo:
We investigate the size and power properties of the AH test of evolutionary change. This involves examining whether the size results are sensitive to both the number of individual frequencies estimated and the spectral shape adopted under the null hypothesis. The power tests examine whether the test has good power to detect shifts in both spectral position (variance) and spectral shape (autocovariance structure).
Resumo:
As the use of technological devices in everyday environments becomes more prevalent, it is clear that access to these devices has become an important aspect of occupational performance. Children are increasingly required to competently manipulate technology such as the computer to fulfil occupational roles of student and player. Occupational therapists are in a position to facilitate the successful interface between children and standard computer technologies. The literature has supported the use of direct manipulation interfaces in computing that requires mastery of devices such as the mouse. Identification of children likely to experience difficulties with mouse use will inform the development of appropriate methods of intervention promoting mouse skill and further enhance participation in occupational tasks. The aim of this paper is to discuss the development of an assessment of mouse proficiency for children. It describes the construction of the assessment, the content of the test, and its content validity.
Resumo:
Purpose: The aim of this study was to assess the accuracy of a (CO2)-C-13 breath test for the prediction of short-duration energy expenditure. Methods: Eight healthy volunteers walked at 1.5 km.h(-1) for 60 min followed by 60-min recovery. During this time, the energy cost of physical activity was measured via respiratory calorimetry and a C-13 bicarbonate breath test. A further eight subjects were tested using the same two methods during a 60-min cycle at 0.5 kp. 30 ipm followed by a 60-min recovery. The rate of appearance of (CO2)-C-13, (RaCO2) was measured and the mean ratio, (V) over dot CO2/RaCO2 was used to calculate energy expenditure using the isotopic approach. Results: As would be expected, there was a significant difference in the energy cost of walking and cycling using both methods (P < 0.05). However. no significant differences were observed between respiratory calorimetry and the isotope method for measurement of energy expenditure while walking or cycling. Conclusions: These data suggest that the C-13 breath test is a valid method that can be used to measure the energy cost of short duration physical activity in a field setting.
Resumo:
We tested the hypothesis that tree species in a subtropical rain forest in south-east Queensland are ecologically equivalent and therefore have identical environmental requirements for their regeneration. We assessed the evidence that juveniles of species differed in their distributions in treefall gap microsites and along gradients of light availability, soil pH, soil PO4-P availability and soil NO3-N availability. Pairwise comparisons were made on a subset of the common species selected on the basis that they showed a relatively high level of positive association, and would therefore, a priori, be expected to have similar regeneration requirements. Detailed comparisons between the species failed to demonstrate evidence for species differentiation with respect to their tolerance of the disturbance associated with gap microsites or to the gradient of NO3-N availability. However, species differed markedly in their distributions along the soil pH gradient and along the gradients of light availability and soil PO4-P availability. The overall level of ecological differentiation between the species is high: seven out of the 10 possible species pairings showed evidence for ecological differentiation. Such niche differentiation amongst the juveniles of tree species may play an important role in maintaining the species richness of rain-forest communities.
Resumo:
The association of sustained cerebral edema with poor neurological outcome following hypoxia-ischaemia in the neonate suggests that measurement of cerebral edema may allow early prediction of outcome in these infants. Direct measurements of cerebral impedance have been widely used in animal studies to monitor cerebral edema, but such invasive measurements are not possible in the human neonate. This study investigated the ability of noninvasive cerebral impedance measurements to detect cerebral edema following hypoxia-ischaemia. One-day-old piglets were anaesthetized, intubated and ventilated. Hypoxia was induced by reducing the inspired oxygen concentration to 4-6% O-2. Noninvasive cerebral bioimpedance was measured using gel electrodes attached to the scalp. Cerebral bioimpedance was also measured directly by insertion of two silver-silver chloride electrodes subdurally. Noninvasive and invasive measurements were made before, during and after hypoxia. Whole body impedance was measured to assess overall fluid movements. Intracranial pressure was measured continuously via a catheter inserted subdurally, as an index of cerebral edema. There was good agreement between noninvasive and invasive measurements of cerebral impedance although externally obtained responses were attenuated. Noninvasive measurements were also well correlated with intracranial pressure. Whole body impedance changes did not account for increases in noninvasively measured cerebral impedance. Results suggest that noninvasive cerebral impedance measurements do reflect intracranial events, and are able to detect cerebral edema following hypoxia-ischaemia in the neonate. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Involvement of nerve tissue may contribute to the persistence of pain following a whiplash injury. This study aimed to investigate responses to the brachial plexus provocation test (BPPT) in 156 subjects with chronic whiplash associated disorder (WAD) with and without associated arm pain and 95 asymptomatic control subjects. The range of elbow extension (ROM) and visual analogue scale (VAS) pain scores were measured. Subjects with chronic WAD demonstrated significantly less ROM and higher VAS scores with the BPPT than the asymptomatic subjects (P
Resumo:
Current noninvasive techniques for the routine and frequent quantification of peripheral lymphedema in patients are total limb volume measurement (by water immersion or by circumferential measurements) and bioelectrical impedance analysis (BIA). However both of these techniques require standardizing the measurement using a contralateral measurement from the unaffected limb, Hence these techniques are essentially restricted to unilateral lymphedema. This paper describes the results from a preliminary study to investigate an alternative approach to the analysis of the data from multiple frequency BIA to produce an index of lymphedema without the need for normalization to another body segment. Twenty patients receiving surgical treatment for breast cancer were monitored prior to surgery and again after diagnosis with unilateral lymphedema. The data recorded were total limb volume, by circumferential measurements; and BIA measurements of both limbs. From these measurements total limb volumes and extracellular fluid volumes were calculated and expressed as ratios of the affected limb to that of the unaffected limb. An index of the ratio of the extracellular fluid volume to the intracellular fluid volume was determined. This ECW/ICW index was calculated for both the affected and unaffected limbs at both measurement times. Results confirmed that the established techniques of total limb volume and extracellular fluid volume normalized to the unaffected contralateral limb were accurate in the detection of lymphedema (p < 10(-6)). Comparison of the ECW/ICW index from the affected limb after diagnosis with that from the pre-surgery measurement revealed a significant (p< 10(-6)) and considerable (75%) increase. The results of this pilot study suggest that by using multiple frequency bioelectrical impedance analysis, an index of the ECW/ICW ratio can be obtained and this index appears to have an equal, or better, sensitivity, than the other techniques in detecting lymphedema. More importantly, this index does not require normalization to another body segment and can be used to detect all types of peripheral edema including both unilateral and bilateral lymphedema.
Resumo:
To establish a noncontagious control for the Ray thioglycollate test for the detection of Perkinsus in mollusks we evaluated nonviable stages of P. olseni for enlargement of hypnospores and blue/black iodine stain. Trophozoites made nonviable with formalin, irradiation or colchicine failed to swell in thioglycollate. They remained small and did not differentially stain in iodine. Trophozoites that had already developed into hypnospores in thioglycollate were rendered inactive by freezing, ethanol or formalin immersion. They retained their iodinophilic properties and thus could provide a partial control for the Ray Test.
Resumo:
Concussion severity grades according to the Cantu, Colorado Medical Society, and American Academy of Neurology systems were not clearly related to the presence or duration of impaired neuropsychological test performance in 21 professional rugby league athletes. The use of concussion severity guidelines and neuropsychological testing to assist return to play decisions requires further investigation.