180 resultados para indicators’ improvement method
Resumo:
The reconstruction of power industries has brought fundamental changes to both power system operation and planning. This paper presents a new planning method using multi-objective optimization (MOOP) technique, as well as human knowledge, to expand the transmission network in open access schemes. The method starts with a candidate pool of feasible expansion plans. Consequent selection of the best candidates is carried out through a MOOP approach, of which multiple objectives are tackled simultaneously, aiming at integrating the market operation and planning as one unified process in context of deregulated system. Human knowledge has been applied in both stages to ensure the selection with practical engineering and management concerns. The expansion plan from MOOP is assessed by reliability criteria before it is finalized. The proposed method has been tested with the IEEE 14-bus system and relevant analyses and discussions have been presented.
Resumo:
Modeling volcanic phenomena is complicated by free-surfaces often supporting large rheological gradients. Analytical solutions and analogue models provide explanations for fundamental characteristics of lava flows. But more sophisticated models are needed, incorporating improved physics and rheology to capture realistic events. To advance our understanding of the flow dynamics of highly viscous lava in Peléean lava dome formation, axi-symmetrical Finite Element Method (FEM) models of generic endogenous dome growth have been developed. We use a novel technique, the level-set method, which tracks a moving interface, leaving the mesh unaltered. The model equations are formulated in an Eulerian framework. In this paper we test the quality of this technique in our numerical scheme by considering existing analytical and experimental models of lava dome growth which assume a constant Newtonian viscosity. We then compare our model against analytical solutions for real lava domes extruded on Soufrière, St. Vincent, W.I. in 1979 and Mount St. Helens, USA in October 1980 using an effective viscosity. The level-set method is found to be computationally light and robust enough to model the free-surface of a growing lava dome. Also, by modeling the extruded lava with a constant pressure head this naturally results in a drop in extrusion rate with increasing dome height, which can explain lava dome growth observables more appropriately than when using a fixed extrusion rate. From the modeling point of view, the level-set method will ultimately provide an opportunity to capture more of the physics while benefiting from the numerical robustness of regular grids.
Resumo:
Historically, business process design has been driven by business objectives, specifically process improvement. However this cannot come at the price of control objectives which stem from various legislative, standard and business partnership sources. Ensuring the compliance to regulations and industrial standards is an increasingly important issue in the design of business processes. In this paper, we advocate that control objectives should be addressed at an early stage, i.e., design time, so as to minimize the problems of runtime compliance checking and consequent violations and penalties. To this aim, we propose supporting mechanisms for business process designers. This paper specifically presents a support method which allows the process designer to quantitatively measure the compliance degree of a given process model against a set of control objectives. This will allow process designers to comparatively assess the compliance degree of their design as well as be better informed on the cost of non-compliance.
Resumo:
Aim: Unless specifically treated (glucocorticoids in low doses), Familial Hyperaldosteronism Type I(FH-I) may result in early death from stroke. We report the successful application of a rapid, polymerase chain reaction (PCR)-based method of detecting the 'hybrid' 11 beta-hydroxylase (11 beta-OHase)/aldosterone synthase (AS) gene as a screening test for FH-I. Methods: 'Long-PCR' was used to amplify, concurrently, a 4 kb fragment of AS gene (both primers AS-specific) and a 4 kb fragment of the hybrid gene (5' primer 11 beta-OHase-specific, 3'primer AS-specific) from DNA extracted from blood either collected locally or transported from elsewhere. Sample collection and transport were straightforward. This 4 kb fragment contains all the currently recognised hybrid gene 'crossover' points. Results: Within a single family, long-PCR identified all 21 individuals known to have FH-I. Hypertension was corrected in all 11 treated with glucocorticoids. Nine with normal blood pressure are being closely followed for development of hypertension. Long-PCR cord blood analysis excluded FH-I in three neonates born to affected individuals. Long-PCR newly identified two other affected families: (1) a female (60 years) with a personal and family history of stroke and her normotensive daughter (40 years), and (2) a female (51 years) previously treated for primary aldosteronism with amiloride, her two hypertensive sons (14 and 16 years) and her hypertensive mother (78 years). No false negative or false positive results have yet been encountered. At least seven other centres have successfully performed this test. Conclusion: Long-PCR is a reliable method of screening individuals of all ages for FH-I.
Resumo:
This communication describes an improved one-step solid-phase extraction method for the recovery of morphine (M), morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G) from human plasma with reduced coextraction of endogenous plasma constituents, compared to that of the authors' previously reported method. The magnitude of the peak caused by endogenous plasma components in the chromatogram that eluted immediately before the retention time of M3G has been reduced (similar to 80%) significantly (p < 0.01) while achieving high extraction efficiencies for the compounds of interest, viz morphine, M6G, and M3G (93.8 +/- 2.5, 91.7 +/- 1.7, and 93.1 +/- 2.2%, respectively). Furthermore, when the improved solid-phase extraction method was used, the extraction cartridge-derived late-eluting peak (retention time 90 to 100 minutes) reported in our previous method, was no longer present in the plasma extracts. Therefore the combined effect of reducing the recovery of the endogenous components of plasma that chromatographed just before the retention time of M3G and the removal of the late-eluting, extraction cartridge-derived peak has resulted in a decrease in the chromatographic run-time to 20 minutes, thereby increasing the sample throughput by up to 100%.
Resumo:
The large fat globules that can be present in UHT milk due to inadequate homogenisation cause a cream layer to form that limits the shelf life of UHT milk. Four different particle size measurement techniques were used to measure the size of fat globules in poorly homogenised UHT milk processed in a UHT pilot plant. The thickness of the cream layer that formed during storage was negatively correlated with homogenisation pressure. It was positively correlated with the mass mean diameter and the percentage volume of particles between 1.5 and 2 mu m diameter, as determined by laser light scattering using the Malvern Mastersizer. Also, the thickness of the cream layer was positively correlated with the volume mode diameter and the percentage volume of particles between 1.5 and 2 mu m diameter, as determined by electrical impedance using the Coulter Counter. The cream layer thickness did not correlate significantly with the Coulter Counter measurements of volume mean diameter, or volume percentages of particles between 2 and 5 mu m or 5 and 10 mu m diameter. Spectroturbidimetry (Emulsion Quality Analyser) and light microscopy analyses were found to be unsuitable for assessing the size of the fat particles. This study suggests that the fat globule size distribution as determined by the electrical impedance method (Coulter Counter) is the most useful for determining the efficiency of homogenisation and therefore for predicting the stability of the fat emulsion in UHT milk during storage.
Resumo:
A hydride cold-trapping technique was developed and optimised for the measurement of urinary arsenic metabolites. The analytical precision of the method was found to be 6.1, 4.0 and 4.8% (n = 5) for inorganic arsenic (As-i), monomethylarsonate (MMA) and dimethylarsinate (DMA), respectively, with recoveries close to 100%, The detection limits were 1.0, 1.3 and 3 ng for As-i, MMA and DMA, respectively. The method was then used to analyse urine samples obtained from three groups of workers for occupational exposure in three companies where copper chrome arsenate was used for timber treatment. The results were compared with those for a normal control group of laboratory workers. Arsenic and its metabolites were also measured in experimental rats given 5 mg As kg(-1) body mass by oral gavage in the form of sodium arsenite, calcium arsenite or sodium arsenate. Occupational workers showed a significantly higher excretion of As-i, Up to two fold increases of urinary As-i excretion in rats compared with control rats were also observed in animals dosed with various forms of arsenicals. The method is suitable for the measurement of arsenic metabolites in urine of both humans and experimental animals.
Resumo:
A novel screening strategy has been developed for the identification of alpha-chymotrypsin inhibitors from a phage peptide library. In this strategy, the standard affinity selection protocol was modified by adding a proteolytic cleavage period to avoid recovery of alpha-chymotrypsin substrates. After four cycles of selection and further activity assay, a group of related peptides were identified by DNA sequencing. These peptides share a consensus sequence motif as (S/T)RVPR(R/H). Then, a corresponding short peptide (Ac-ASRVPRRG-NH2) was synthesized chemically and proved to be an inhibitor of alpha-chymotrypsin. The present work provides a useful way for searching proteinase inhibitors without detailed knowledge of the molecular structure.
Resumo:
A sensitive and reproducible solid-phase extraction (SPE) method for the quantification of oxycodone in human plasma was developed. Varian Certify SPE cartridges containing both C-8 and benzoic acid functional groups were the most suitable for the extraction of oxycodone and codeine (internal standard), with consistently high (greater than or equal to 80%) and reproducible recoveries. The elution mobile phase consisted of 1.2 ml of butyl chloride-isopropanol (80:20, v/v) containing 2% ammonia. The quantification limit for oxycodone was 5.3 pmol on-column. Within-day and inter-day coefficients of variation were 1.2% and 6.8% respectively for 284 nM oxycodone and 9.5% and 6.2% respectively for 28.4 nM oxycodone using 0.5-ml plasma aliquots. (C) 1998 Elsevier Science BN. All rights reserved.
Resumo:
An automated method for extracting brain volumes from three commonly acquired three-dimensional (3D) MR images (proton density, T1 weighted, and T2-weighted) of the human head is described. The procedure is divided into four levels: preprocessing, segmentation, scalp removal, and postprocessing. A user-provided reference point is the sole operator-dependent input required, The method's parameters were first optimized and then fixed and applied to 30 repeat data sets from 15 normal older adult subjects to investigate its reproducibility. Percent differences between total brain volumes (TBVs) for the subjects' repeated data sets ranged from .5% to 2.2%. We conclude that the method is both robust and reproducible and has the potential for wide application.
Resumo:
A novel pore tailoring method is proposed by which the pore-opening sizes of MCM-41 materials can be finely tuned without significant loss in pore volume and surface area.
Resumo:
We describe two ways of optimizing score functions for protein sequence to structure threading. The first method adjusts parameters to improve sequence to structure alignment. The second adjusts parameters so as to improve a score function's ability to rank alignments calculated in the first score function. Unlike those functions known as knowledge-based force fields, the resulting parameter sets do not rely on Boltzmann statistics, have no claim to representing free energies and are purely constructions for recognizing protein folds. The methods give a small improvement, but suggest that functions can be profitably optimized for very specific aspects of protein fold recognition, Proteins 1999;36:454-461. (C) 1999 Wiley-Liss, Inc.
Resumo:
Objective: We compared service consumption, continuity of care and risk of readmission in a record linkage follow-up study of cohorts of patients with schizophrenia and related disorders in Victoria (Australia) and in Groningen (The Netherlands). These areas are interesting to compare because mental health care is in a different stage of deiustitutionalization. More beds are available in Groningen and more community resources are available in Victoria. Method: The cohorts were followed for 4 years, since discharge from inpatient services using record linkage data available in the psychiatric case-registers in both areas. Survival analysis was used to study continuity of care and risk of readmission. Results: Available indicators showed a higher level of continuity of care in Victoria. While the relative risk of readmission was the same in both areas and not affected by aftercare contact after discharge, the number of days spent in hospital was much higher in the Groningen register area. Conclusion: These findings provide further support for earlier reports that the risk of readmission is predominantly affected by attributes of mental illness. However, the duration of admissions, is strongly affected by service system variables, including the provision of continuity of care.