67 resultados para cost drivers


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The humpback whales that migrate along the east coast of Australia were hunted to near-extinction in the 1950s and early 1960s. Two independent series of land-based surveys conducted over the last 25 years during the whales’ northward migration along the Australian coastline have demonstrated a rapid increase in the size of the population. In 2004 we conducted a survey of the migratory population as a continuation of these series of surveys. Two methods of data analysis were used in line with the previous surveys, both for calculation of absolute and relative abundance. We consider the best estimates for 2004 to be 7,090 ± 660 (95% CI) whales with an annual rate of increase of 10.6 ± 0.5% (95% CI) for 1987 – 2004. The rate of increase agrees with those previously obtained for this population and demonstrates the continuation of a strong post-exploitation recovery. While there are still some uncertainties concerning the absolute abundance estimate and structure of this population, the rate of annual increase should be independent of these and highly robust.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Least-Cost Planning played a key role in the development of the energy efficiency and renewable energy industries in the USA, It has not been widely used elsewhere, largely due to differences in other nations' regulatory environments and the emergence of competitive markets as the dominant paradigm for electricity planning, Least-Cost Planning, however may over valuable insights for creating regulatory framework for competitive electricity markers. This paper examines some lessons which may be extracted from an analysis of the Least-Cost Planning experience in the USA and suggests how these lessons might prove beneficial in guiding Australia's electricity industry reform, This analysis demonstrates how market-based reforms may be flawed if they ignore the history of previous reform processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Although digital and videotaped images are known to be comparable for the evaluation of left ventricular function, their relative accuracy for assessment of more complex anatomy is unclear. We sought to compare reading time, storage costs, and concordance of video and digital interpretations across multiple observers and sites. Methods. One hundred one patients with valvular (90 mitral, 48 aortic, 80 tricuspid) disease were selected prospectively, and studies were stored according to video and standardized digital protocols. The same reviewer interpreted video and digital images independently and at different times with the use of a standard report form to evaluate 40 items (eg, severity of stenosis or regurgitation, leaflet thickening, and calcification) as normal or mildly, moderately, or severely abnormal Concordance between modalities was expressed at kappa Major discordance (difference of >1 level of severity) was ascribed to the modality that gave the lesser severity. CD-ROM was used to store digital data (20:1 lossy compression), and super-VHS video-tape was used to store video data The reading time and storage costs for each modality were compared Results. Measured parameters were highly concordant (ejection fraction was 52% +/- 13% by both). Major discordance was rare, and lesser values were reported with digital rather than video interpretation in the categories of aortic and mitral valve thicken ing (1% to 2%) and severity of mitral regurgitation (2%). Digital reading time was 6.8 +/- 2.4 minutes, 38% shorter than with video (11.0 +/- 3.0, range 8 to 22 minutes, P < .001). Compressed digital studies had an average size of 60 <plus/minus> 14 megabytes (range 26 to 96 megabytes). Storage cost for video was A$0.62 per patient (18 studies per tape, total cost A$11.20), compared with A$0.31 per patient for digital storage (8 studies per CD-ROM, total cost A$2.50). Conclusion. Digital and video interpretation were highly concordant; in the few cases of major discordance, the digital scores were lower, perhaps reflecting undersampling. Use of additional views and longer clips may be indicated to minimize discordance with video in patients with complex problems. Digital interpretation offers a significant reduction in reading times and the cost of archiving.