295 resultados para clinical measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The measurement of alcohol craving began with single-item scales. Multifactorial scales developed with the intention to capture more fully the phenomenon of craving. This study examines the construct validity of a multifactorial scale, the Yale-Brown Obsessive Compulsive Scale for heavy drinking (Y-BOCS-hd). The study compares its clinical utility with a single item visual-analogue craving scale. The study includes 212 alcohol dependent subjects (127 males, 75 females) undertaking an outpatient treatment program between 1999-2001. Subjects completed the Y-BOCS-hd and a single item visual-analogue scale, in addition to alcohol consumption and dependence severity measures. The Y-BOCS-hd had strong construct validity. Both the visual-analogue alcohol craving scale and Y-BOCS-hd were weakly associated with pretreatment dependence severity. There was a significant association between pretreatment alcohol consumption and the visual-analogue craving scale. Neither craving measure was able to predict total program abstinence or days abstinent. The relationship between obsessive-compulsive behavior in alcohol dependence and craving remains unclear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In magnetic resonance imaging (MRI), the MR signal intensity can vary spatially and this spatial variation is usually referred to as MR intensity nonuniformity. Although the main source of intensity nonuniformity arises from B, inhomogeneity of the coil acting as a receiver and/or transmitter, geometric distortion also alters the MR signal intensity. It is useful on some occasions to have these two different sources be separately measured and analyzed. In this paper, we present a practical method for a detailed measurement of the MR intensity nonuniformity. This method is based on the same three-dimensional geometric phantom that was recently developed for a complete measurement of the geometric distortion in MR systems. In this paper, the contribution to the intensity nonuniformity from the geometric distortion can be estimated and thus, it provides a mechanism for estimation of the intensity nonuniformity that reflects solely the spatial characteristics arising from B-1. Additionally, a comprehensive scheme for characterization of the intensity nonuniformity based on the new measurement method is proposed. To demonstrate the method, the intensity nonuniformity in a 1.5 T Sonata MR system was measured and is used to illustrate the main features of the method. (c) 2005 American Association of Physicists in Medicine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report here a validated method for the quantification of a new immunosuppressant drug FTY720, using HPLC-tandem mass spectrometry. Whole blood samples (500 mu l) were subjected to liquid-liquid extraction, in the presence of an internal standard (Y-32919). Mass spectrometric detection was by selected reaction monitoring with an atmospheric pressure chemical ionization source in positive ionization mode (FTY720: m/z 308.3 -> 255.3). The assay was linear from 0.2 to 25 mu g/l (r(2) > 0.997, n = 5). The inter- and intra-day analytical recovery and imprecision for quality control samples (0.5, 7 and 15 mu g/l) were 95.8-103.2 and < 5.5%, respectively. At the lower limit of quantification (0.2 mu g/l) the interand intra-day analytical recovery was 99.0-102.8% with imprecision of < 7.6% (n = 5). The assay had a mean relative recovery of 100.5 +/- 5.8% (n = 15). Extracted samples were stable for 16 h. IFTY720 quality control samples were stable at room temperature for 16 h at 4 degrees C for at least 8 days and when taken through at least three freeze-thaw cycles. In conclusion, the method described displays analytical performance characteristics that are suitable for pharmacokinetic studies in humans. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Strain and strain rate (SR) are measures of deformation that are basic descriptors of both the nature and the function of cardiac tissue. These properties may now be measured using either Doppler or two-dimensional ultrasound techniques. Although these measurements are feasible in routine clinical echocardiography, their acquisition and analysis nonetheless presents a number of technical challenges and complexities. Echocardiographic strain and SR imaging has been applied to the assessment of resting ventricular function, the assessment of myocardial viability using low-dose dobutamine infusion, and stress testing for ischemia. Resting function assessment has been applied in both the left and the fight ventricles, and may prove particularly valuable for identifying myocardial diseases and following up the treatment response. Although the evidence base is limited, SR imaging seems to be feasible and effective for the assessment of myocardial viability. The use of the technique for the detection of ischemia during stress echocardiography is technically challenging and likely to evolve further. The clinical availability of strain and SR measurement may offer a solution to the ongoing need for quantification of regional and global cardiac function. Nonetheless, these techniques are susceptible to artifact, and further technical development is necessary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Design. Development of an automatic measurement algorithm and comparison with manual measurement methods. Objectives. To develop a new computer-based method for automatic measurement of vertebral rotation in idiopathic scoliosis from computed tomography images and to compare the automatic method with two manual measurement techniques. Summary of Background Data. Techniques have been developed for vertebral rotation measurement in idiopathic scoliosis using plain radiographs, computed tomography, or magnetic resonance images. All of these techniques require manual selection of landmark points and are therefore subject to interobserver and intraobserver error. Methods. We developed a new method for automatic measurement of vertebral rotation in idiopathic scoliosis using a symmetry ratio algorithm. The automatic method provided values comparable with Aaro and Ho's manual measurement methods for a set of 19 transverse computed tomography slices through apical vertebrae, and with Aaro's method for a set of 204 reformatted computed tomography images through vertebral endplates. Results. Confidence intervals (95%) for intraobserver and interobserver variability using manual methods were in the range 5.5 to 7.2. The mean (+/- SD) difference between automatic and manual rotation measurements for the 19 apical images was -0.5 degrees +/- 3.3 degrees for Aaro's method and 0.7 degrees +/- 3.4 degrees for Ho's method. The mean (+/- SD) difference between automatic and manual rotation measurements for the 204 endplate images was 0.25 degrees +/- 3.8 degrees. Conclusions. The symmetry ratio algorithm allows automatic measurement of vertebral rotation in idiopathic scoliosis without intraobserver or interobserver error due to landmark point selection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Previous studies have identified no strong correlation between patients' height and tracheal length in anaesthetized patients. We have attempted to compare vocal cords-carina distance (VCD) in Chinese patients with the dimensions of five commonly used tracheal tubes. In addition, we attempted to find a surface anatomy measurement that would identify patients with 'short tracheas'. Methods. We measured VCD in 130 anaesthetized Chinese patients with a fibreoptic bronchoscope. Also measurements were obtained of the distal ends of five commonly used tracheal tubes. We undertook various surface anatomy measurements on the patients' chest and neck region to predict those patients with short tracheas. Results. VCD averaged 12.6 ((SD) 1.4) cm. In seven patients (5%) this distance was particularly short (between 8.8 and 10.4 cm). Many of the commonly used tracheal tubes would be placed close to or beyond the carina when the black intubation guide mark(s) is (are) at the level of the vocal cords. The VCD of

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We carried out a retrospective review of the videoconference activity records in a university-run hospital telemedicine studio. Usage records describing videoconferencing activity in the telemedicine studio were compared with the billing records provided by the telecommunications company. During a seven-month period there were 211 entries in the studio log: 108 calls made from the studio and 103 calls made from a far-end location. We found that 103 calls from a total of 195 calls reported by the telecommunications company were recorded in the usage log. The remaining 92 calls were not recorded, probably for one of several reasons, including: failed calls-a large number of unrecorded calls (57%) lasted for less than 2 min (median 1.6 min); origin of videoconference calls-calls may have been recorded incorrectly in the usage diary (i.e. as being initiated from the far end, when actually initiated from the studio); and human error. Our study showed that manual recording of videoconference activity may not accurately reflect the actual activity taking place. Those responsible for recording and analysing videoconference activity, particularly in large telemedicine networks, should do so with care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is substantial disagreement among published epidemiological studies regarding environmental risk factors for Parkinson’s disease (PD). Differences in the quality of measurement of environmental exposures may contribute to this variation. The current study examined the test–retest repeatability of self-report data on risk factors for PD obtained from a series of 32 PD cases recruited from neurology clinics and 29 healthy sex-, age-and residential suburb-matched controls. Exposure data were collected in face-to-face interviews using a structured questionnaire derived from previous epidemiological studies. High repeatability was demonstrated for ‘lifestyle’ exposures, such as smoking and coffee/tea consumption (kappas 0.70–1.00). Environmental exposures that involved some action by the person, such as pesticide application and use of solvents and metals, also showed high repeatability (kappas>0.78). Lower repeatability was seen for rural residency and bore water consumption (kappa 0.39–0.74). In general, we found that case and control participants provided similar rates of incongruent and missing responses for categorical and continuous occupational, domestic, lifestyle and medical exposures.