168 resultados para Measurement Techniques, Fibreoptic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study determined the inter-tester and intra-tester reliability of physiotherapists measuring functional motor ability of traumatic brain injury clients using the Clinical Outcomes Variable Scale (COVS). To test inter-tester reliability, 14 physiotherapists scored the ability of 16 videotaped patients to execute the items that comprise the COVS. Intra-tester reliability was determined by four physiotherapists repeating their assessments after one week, and three months later. The intra-class correlation coefficients (ICC) were very high for both inter-tester reliability (ICC > 0.97 for total COVS scores, ICC > 0.93 for individual COVS items) and intra-tester reliability (ICC > 0.97). This study demonstrates that physiotherapists are reliable in the administration of the COVS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A piecewise uniform fitted mesh method turns out to be sufficient for the solution of a surprisingly wide variety of singularly perturbed problems involving steep gradients. The technique is applied to a model of adsorption in bidisperse solids for which two fitted mesh techniques, a fitted-mesh finite difference method (FMFDM) and fitted mesh collocation method (FMCM) are presented. A combination (FMCMD) of FMCM and the DASSL integration package is found to be most effective in solving the problems. Numerical solutions (FMFDM and FMCMD) were found to match the analytical solution when the adsorption isotherm is linear, even under conditions involving steep gradients for which global collocation fails. In particular, FMCMD is highly efficient for macropore diffusion control or micropore diffusion control. These techniques are simple and there is no limit on the range of the parameters. The techniques can be applied to a variety of adsorption and desorption problems in bidisperse solids with non-linear isotherm and for arbitrary particle geometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental mechanical sieving methods are applied to samples of shellfish remains from three sites in southeast Queensland, Seven Mile Creek Mound, Sandstone Point and One-Tree, to test the efficacy of various recovery and quantification procedures commonly applied to shellfish assemblages in Australia. There has been considerable debate regarding the most appropriate sieve sizes and quantification methods that should be applied in the recovery of vertebrate faunal remains. Few studies, however, have addressed the impact of recovery and quantification methods on the interpretation of invertebrates, specifically shellfish remains. In this study, five shellfish taxa representing four bivalves (Anadara trapezia, Trichomya hirsutus, Saccostrea glomerata, Donax deltoides) and one gastropod (Pyrazus ebeninus) common in eastern Australian midden assemblages are sieved through 10mm, 6.3mm and 3.15mm mesh. Results are quantified using MNI, NISP and weight. Analyses indicate that different structural properties and pre- and postdepositional factors affect recovery rates. Fragile taxa (T. hirsutus) or those with foliated structure (S. glomerata) tend to be overrepresented by NISP measures in smaller sieve fractions, while more robust taxa (A. trapezia and P. ebeninus) tend to be overrepresented by weight measures. Results demonstrate that for all quantification methods tested a 3mm sieve should be used on all sites to allow for regional comparability and to effectively collect all available information about the shellfish remains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extracting human postural information from video sequences has proved a difficult research question. The most successful approaches to date have been based on particle filtering, whereby the underlying probability distribution is approximated by a set of particles. The shape of the underlying observational probability distribution plays a significant role in determining the success, both accuracy and efficiency, of any visual tracker. In this paper we compare approaches used by other authors and present a cost path approach which is commonly used in image segmentation problems, however is currently not widely used in tracking applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Force measurement in hypervelocity expansion tubes is not possible using conventional techniques. The stress wave force balance technique can be applied in expansion tubes to measure forces despite the short test times involved. This paper presents a new calibration technique for multiple-component stress wave force balances where an impulse response created using a load distribution is required and no orthogonal surfaces on the model exist.. This new technique relies on the tensorial superposition of single-component impulse responses analogous to the vectorial superposition of the calibration loads. The example presented here is that of a scale model of the Mars Pathfinder, but the technique is applicable to any geometry and may be useful for cases where orthogonal loads cannot be applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although it is well known that high Na concentrations induce Ca deficiency in acidic conditions, the effect of high pH on this competitive mechanism is not so well understood. The effect of Ca activity ratio (CAR) and pH on the Ca uptake of mungbeans (Vigna radiata (L.) Wilczek cv. Emerald) and Rhodes grass (Chloris gayana cv. Pioneer) in Na dominated solution cultures and in soil was investigated. Changes in pH in the alkaline range were shown not to affect the critical CAR of 0.024 (corresponding to 90 % relative root length) for mungbeans grown in solution culture. Results from soil grown mungbeans confirmed those from solution culture, with a critical CAR of 0.025. A critical CAR of 0.034 was also established for soil grown Rhodes grass. The similarity of critical values established for mungbeans and Rhodes grass in solution culture and soil justifies the use of both solution culture and soil solution measurement as techniques for studying plant growth and limitations across plant species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the increasing prevalence of salinity world-wide, the measurement of exchangeable cation concentrations in saline soils remains problematic. Two soil types (Mollisol and Vertisol) were equilibrated with a range of sodium adsorption ratio (SAR) solutions at various ionic strengths. The concentrations of exchangeable cations were then determined using several different types of methods, and the measured exchangeable cation concentrations compared to reference values. At low ionic strength (low salinity), the concentration of exchangeable cations can be accurately estimated from the total soil extractable cations. In saline soils, however, the presence of soluble salts in the soil solution precludes the use of this method. Leaching of the soil with a pre-wash solution (such as alcohol) was found to effectively remove the soluble salts from the soil, thus allowing the accurate measurement of the effective cation exchange capacity (ECEC). However, the dilution associated with this pre-washing increased the exchangeable Ca concentrations while simultaneously decreasing exchangeable Na. In contrast, when calculated as the difference between the total extractable cations and the soil solution cations, good correlations were found between the calculated exchangeable cation concentrations and the reference values for both Na (Mollisol: y=0.873x and Vertisol: y=0.960x) and Ca (Mollisol: y=0.901x and Vertisol: y=1.05x). Therefore, for soils with a soil solution ionic strength greater than 50 mM (electrical conductivity of 4 dS/m) (in which exchangeable cation concentrations are overestimated by the assumption they can be estimated as the total extractable cations), concentrations can be calculated as the difference between total extractable cations and soluble cations.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a contradiction of quantum mechanics with local hidden variable theories for continuous quadrature phase amplitude (position and momentum) measurements. For any quantum state, this contradiction is lost for situations where the quadrature phase amplitude results are always macroscopically distinct. We show that for optical realizations of this experiment, where one uses homodyne detection techniques to perform the quadrature phase amplitude measurement, one has an amplification prior to detection, so that macroscopic fields are incident on photodiode detectors. The high efficiencies of such detectors may open a way for a loophole-free test of local hidden variable theories.