67 resultados para Hydrogen-21 Centimeter Absorption
Resumo:
Heterogeneous copper catalyst was developed using the mesoporous molecular sieve MCM-41 as the catalyst support. Copper was impregnated onto the support. Catalysts with different copper loadings were obtained. The performance of the developed catalysts was evaluated in photochemically enhanced oxidation of phenol using hydrogen peroxide as the oxidant. The catalyst was found to significantly increase the oxidation rate and enhance the removal level of phenol with UV light present. The effects of copper loading on the catalyst, photo (UV), H2O2 concentration, and catalyst dosage on the photo-oxidation of phenol were studied. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
A number of mathematical models have been used to describe percutaneous absorption kinetics. In general, most of these models have used either diffusion-based or compartmental equations. The object of any mathematical model is to a) be able to represent the processes associated with absorption accurately, b) be able to describe/summarize experimental data with parametric equations or moments, and c) predict kinetics under varying conditions. However, in describing the processes involved, some developed models often suffer from being of too complex a form to be practically useful. In this chapter, we attempt to approach the issue of mathematical modeling in percutaneous absorption from four perspectives. These are to a) describe simple practical models, b) provide an overview of the more complex models, c) summarize some of the more important/useful models used to date, and d) examine sonic practical applications of the models. The range of processes involved in percutaneous absorption and considered in developing the mathematical models in this chapter is shown in Fig. 1. We initially address in vitro skin diffusion models and consider a) constant donor concentration and receptor conditions, b) the corresponding flux, donor, skin, and receptor amount-time profiles for solutions, and c) amount- and flux-time profiles when the donor phase is removed. More complex issues, such as finite-volume donor phase, finite-volume receptor phase, the presence of an efflux. rate constant at the membrane-receptor interphase, and two-layer diffusion, are then considered. We then look at specific models and issues concerned with a) release from topical products, b) use of compartmental models as alternatives to diffusion models, c) concentration-dependent absorption, d) modeling of skin metabolism, e) role of solute-skin-vehicle interactions, f) effects of vehicle loss, a) shunt transport, and h) in vivo diffusion, compartmental, physiological, and deconvolution models. We conclude by examining topics such as a) deep tissue penetration, b) pharmacodynamics, c) iontophoresis, d) sonophoresis, and e) pitfalls in modeling.
Resumo:
The H I Parkes All-Sky Survey (HIPASS) is a blind 21 cm survey for extragalactic neutral hydrogen, covering the whole southern sky. The HIPASS Bright Galaxy Catalog (BGC) is a subset of HIPASS and contains the 1000 H I brightest (peak flux density) galaxies. Here we present the 138 HIPASS BGC galaxies that had no redshift measured prior to the Parkes multibeam H I surveys. Of the 138 galaxies, 87 are newly cataloged. Newly cataloged is defined as having no optical ( or infrared) counterpart in the NASA/IPAC Extragalactic Database. Using the Digitized Sky Survey, we identify optical counterparts for almost half of the newly cataloged galaxies, which are typically of irregular or Magellanic morphological type. Several H I sources appear to be associated with compact groups or pairs of galaxies rather than an individual galaxy. The majority ( 57) of the newly cataloged galaxies lie within 10degrees of the Galactic plane and are missing from optical surveys as a result of confusion with stars or dust extinction. This sample also includes newly cataloged galaxies first discovered by Henning et al. in the H I shallow survey of the zone of avoidance. The other 30 newly cataloged galaxies escaped detection because of their low surface brightness or optical compactness. Only one of these, HIPASS J0546-68, has no obvious optical counterpart, as it is obscured by the Large Magellanic Cloud. We find that the newly cataloged galaxies with -b->10degrees are generally lower in H I mass and narrower in velocity width compared with the total HIPASS BGC. In contrast, newly cataloged galaxies behind the Milky Way are found to be statistically similar to the entire HIPASS BGC. In addition to these galaxies, the HIPASS BGC contains four previously unknown H I clouds.
Resumo:
Objectives: Resternotomy is a common part of cardiac surgical practice. Associated with resternotomy are the risks of cardiac injury and catastrophic hemorrhage and the subsequent elevated morbidity and mortality in the operating room or during the postoperative period. The technique of direct vision resternotomy is safe and has fewer, if any, serious cardiac injuries. The technique, the reduced need for groin cannulation and the overall low operative mortality and morbidity are the focus of this restrospective analysis. Methods: The records of 495 patients undergoing 546 resternotomies over a 21-year period to January 2000 were reviewed. All consecutive reoperations by the one surgeon comprised patients over the age of 20 at first resternotomy: M:F 343:203, mean age 57 years (range 20 to 85, median age 60). The mean NYHA grade was 2.3 [with 67 patients (1), 273 (11),159 (111), 43 (IV), and 4 (V classification)] with elective reoperation in 94.6%. Cardiac injury was graded into five groups and the incidence and reasons for groin cannulation estimated. The morbidity and mortality as a result of the reoperation and resternotomy were assessed. Results: The hospital/30 day mortality was 2.9% (95% Cl: 1.6%-4.4%) (16 deaths) over the 21 years. First (481), second (53), and third (12) resternotomies produced 307 uncomplicated technical reopenings, 203 slower but uncomplicated procedures, 9 minor superficial cardiac lacerations, and no moderate or severe cardiac injuries. Direct vision resternotomy is crystalized into the principle that only adhesions that are visualized from below are divided and only sternal bone that is freed of adhesions is sewn. Groin exposure was never performed prophylactically for resternotomy. Fourteen patients (2.6%) had such cannulation for aortic dissection/aneurysm (9 patients), excessive sternal adherence of cardiac structures (3 patients), presurgery cardiac arrest (1 patient), and high aortic cannulation desired and not possible (1 patient). The average postop blood loss was 594 mL (95% CI:558-631) in the first 12 hours. The need to return to the operating room for control of excessive bleeding was 2% (11 patients). Blood transfusion was given in 65% of the resternotomy procedures over the 21 years (mean 854 mL 95% Cl 765-945 mL) and 41% over the last 5 years. Conclusions: The technique of direct vision resternotomy has been associated with zero moderate or major cardiac injury/catastrophic hemorrhage at reoperation. Few patients have required groin cannulation. In the postoperative period, there was acceptable blood loss, transfusion rates, reduced morbidity, and moderate low mortality for this potentially high risk group.
Resumo:
Using data from the H I Parkes All Sky Survey (HIPASS), we have searched for neutral hydrogen in galaxies in a region similar to25x25 deg(2) centred on NGC 1399, the nominal centre of the Fornax cluster. Within a velocity search range of 300-3700 km s(-1) and to a 3sigma lower flux limit of similar to40 mJy, 110 galaxies with H I emission were detected, one of which is previously uncatalogued. None of the detections has early-type morphology. Previously unknown velocities for 14 galaxies have been determined, with a further four velocity measurements being significantly dissimilar to published values. Identification of an optical counterpart is relatively unambiguous for more than similar to90 per cent of our H I galaxies. The galaxies appear to be embedded in a sheet at the cluster velocity which extends for more than 30degrees across the search area. At the nominal cluster distance of similar to20 Mpc, this corresponds to an elongated structure more than 10 Mpc in extent. A velocity gradient across the structure is detected, with radial velocities increasing by similar to500 km s(-1) from south-east to north-west. The clustering of galaxies evident in optical surveys is only weakly suggested in the spatial distribution of our H I detections. Of 62 H I detections within a 10degrees projected radius of the cluster centre, only two are within the core region (projected radius
Resumo:
The synthesis of the hexadentate ligand 2,2,9,9-tetra(methyleneamine)-4,7-dithiadecane (EtN(4)S(2)amp) is reported. The ligand is of a type in which bifurcations of the chain occur at atoms other than donor atoms. The cobalt(III) complex [Co(EtN(4)S(2)amp)](3+) (1) was isolated and characterized. The synthetic methodology also results in a number of by-products, notably 2,9,9-tris(methyleneamine)-9-methylenehydroxy-4,7-dithiadecane (Et(HO)N(3)S(2)amp) and an eleven-membered pendant arm macrocyclic ligand 6,10-dimethyl-6,10-bis(methyleneamine)-1,4-dithia-8-azaacycloundec-7- ene (dmatue). The complexes [Co(Et(HO)N(3)S(2)amp)](3+) (2), in which the alcohol is coordinated to the metal ion, and [Co(dmatue)Cl](2+) (4) were isolated and characterized. Et(HO)N(3)S(2)amp also undergoes complexation with cobalt(III) to produce two isomers endo-[Co(Et(HO) N(3)S(2)amp)Cl](2+) (endo-3) and exo-[Co(Et(HO) N(3)S(2)amp)Cl](2+) (exo-3), both with an uncoordinated alcohol group. endo- 3 has the alcohol positioned cis, and exo-3 trans, to the sixth metal coordination site. Reaction of 1 with isobutyraldehyde, paraformaldehyde and base in dimethylformamide results in the encapsulated complex [Co(1,5,5,9,13,13-hexamethyl-18,21-dithia-3,7,11,15-tetraazabicyclo[7.7.6]docosa- 3,14-diene)](ClO4)(3) . 2H(2)O ([Co(Me(6)docosadieneN(4)S(2))](3+) ( 5). All complexes have been characterized by single crystal X-ray study. The low-temperature (11 K) absorption spectrum of 1 has been measured in Nafion films with spin-allowed (1)A(1g) --> T-1(1g) and (1)A(1g) --> T-1(2g) and spin forbidden (1)A(1g) --> T-3(1g) and (1)A(1g) --> T-3(2g) bands observed. The octahedral ligand-field parameters were determined (10Dq = 22570 cm(-1), B = 551 cm(-1); C = 3500 cm(-1)). For 5 10Dq and B were determined (20580 cm(-1); 516 cm(-1), respectively) and compared with those for similar expanded cavity complexes [Co(Me(8)tricosatrieneN(6))](3+) and [Co(Me(5)tricosatrieneN(6))](3+).
Resumo:
The stress corrosion cracking (SCC) behavior and pre-exposure embrittlement of AZ31 magnesium alloy have been studied by slow strain rate tensile (SSRT) tests in this paper. It is showed that AZ31 sheet material is susceptible to SCC in distilled water, ASTM D1.387 solution, 0.01 M NaCl and 0.1 M NaCl solution. The AZ31 magnesium alloy also becomes embrittled if pre-exposed to 0.01 M NaCl solution prior to tensile testing. The degree of embrittlement increased with increasing the pre-exposure time, It is proposed that both the pre-exposure embrittlement and SCC were due to hydrogen which reduces the cohesive strength. i,e,. hydrogen embrittlement, (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
This study provides an investigation of the availability of octyl salicylate (OS), a common sunscreen agent, from liquid paraffin and the effect of OS on skin permeability. A model membrane system to isolate the vehicle effect from membrane permeability has been developed. Partitioning of OS between liquid paraffin and aqueous receptor phases was conducted. Partition coefficients increased with increase in OS concentration. A range of OS concentrations in liquid paraffin was diffused across human epidermis and synthetic membranes into 4% bovine serum albumin in phosphate-buffered saline and 50% ethanol. Absorption profiles of OS obtained from silicone and low-density polyethylene (LDPE) membranes were similar to each other but higher than for the high-density polyethylene [HDPE (3 times)] membrane and human epidermis (15 times). The steady state fluxes and apparent permeability coefficients (K-p') obtained from the diffusion studies showed the same trends with all membranes, except for the HDPE membrane which showed greater increase in flux and K-p' at concentrations above 30%. IR spectra showed that several bands of OS were shifted with concentrations, and the molecular models further suggested that the main contribution to the self-association is from non-1,4 van der Waals interactions.
Resumo:
1. Drug delivery through the skin has been used to target the epidermis, dermis and deeper tissues and for systemic delivery, The major barrier for the transport of drugs through the skin is the stratum corneum, with most transport occurring through the intercellular region, The polarity of the intercellular region appears to be similar to butanol, with the diffusion of solutes being hindered by saturable hydrogen bonding to the polar head groups of the ceramides, fatty acids and other intercellular lipids, Accordingly, the permeability of the more lipophilic solutes is greatest from aqueous solutions, whereas polar solute permeability is favoured by hydrocarbon-based vehicles. 2. The skin is capable of metabolizing many substances and, through its microvasculature, limits the transport of most substances into regions below the dermis. 3. Although the flux of solutes through the skin should be identical for different vehicles when the solute exists as a saturated solution, the fluxes vary in accordance with the skin penetration enhancement properties of the vehicle. It is therefore desirable that the regulatory standards required for the bioequivalence of topical products include skin studies. 4. Deep tissue penetration can be related to solute protein binding, solute molecular size and dermal blood flow. 5. Iontophoresis is a promising area of skin drug delivery, especially for ionized solutes and when a rapid effect is required. 6. In general, psoriasis and other skin diseases facilitate drug delivery through the skin. 7. It is concluded that the variability in skin permeability remains an obstacle in optimizing drug delivery by this route.
Resumo:
Absorption kinetics of solutes given with the subcutaneous administration of fluids is ill-defined. The gamma emitter, technitium pertechnetate, enabled estimates of absorption rate to be estimated independently using two approaches. In the first approach, the counts remaining at the site were estimated by imaging above the subcutaneous administration site, whereas in the second approach, the plasma technetium concentration-time profiles were monitored up to 8 hr after technetium administration. Boluses of technetium pertechnetate were given both intravenously and subcutaneously on separate occasions with a multiple dosing regimen using three doses on each occasion. The disposition of technetium after iv administration was best described by biexponential kinetics with a V-ss of 0.30 +/- 0.11 L/kg and a clearance of 30.0 +/- 13.1 ml/min. The subcutaneous absorption kinetics was best described as a single exponential process with a half-life of 18.16 +/- 3.97 min by image analysis and a half-life of 11.58 +/- 2.48 min using plasma technetium time data. The bioavailability of technetium by the subcutaneous route was estimated to be 0.96 +/- 0.12. The absorption half-life showed no consistent change with the duration of the subcutaneous infusion. The amount remaining at the absorption site with time was similar when analyzed using image analysis, and plasma concentrations assuming multiexponential disposition kinetics and a first-order absorption process. Profiles of fraction remaining at the absorption sire generated by deconvolution analysis, image analysis, and assumption of a constant first-order absorption process were similar. Slowing of absorption from the subcutaneous administration site is apparent after the last bolus dose in three of the subjects and can De associated with the stopping of the infusion. In a fourth subject, the retention of technetium at the subcutaneous site is more consistent with accumulation of technetium near the absorption site as a result of systemic recirculation.
Resumo:
Encyclopedia of Nanoscience and Nanotechnology® is the World's first encyclopedia ever published in the field of nanotechnology. The 10-volume Encyclopedia is an unprecedented single reference source that provides ideal introduction and overview of most recent advances and emerging new aspects of nanotechnology spanning from science to engineering to medicine. Although there are many books/handbook and journals focused on nanotechnology, no encyclopedic reference work has been published covering all aspects of nanoscale science and technology dealing with materials synthesis, processing, fabrication, probes, spectroscopy, physical properties, electronics, optics, mechanics, biotechnology, devices, etc. The Encyclopedia fills this gap to provide basic information on all fundamental and applied aspects of nanotechnology by drawing on two decades of pioneering research. It is the only scientific work of its kind since the beginning of the field of nanotechnology bringing together core knowledge and the very latest advances. It is written for all levels audience that allows non-scientists to understand the nanotechnology while providing up-to-date latest information to active scientists to experts in the field. This outstanding encyclopedia is an indispensable source for research professionals, technology investors and developers seeking the most up-to-date information on the nanotechnology among a wide range of disciplines from science to engineering to medicine.