111 resultados para Heart autonomic control
Resumo:
Power system real time security assessment is one of the fundamental modules of the electricity markets. Typically, when a contingency occurs, it is required that security assessment and enhancement module shall be ready for action within about 20 minutes’ time to meet the real time requirement. The recent California black out again highlighted the importance of system security. This paper proposed an approach for power system security assessment and enhancement based on the information provided from the pre-defined system parameter space. The proposed scheme opens up an efficient way for real time security assessment and enhancement in a competitive electricity market for single contingency case
Resumo:
Little is known about factors effecting plant growth at high pH, with research often limited by the inability to separate nutritional deficiencies and HCO3- toxicity from the direct limitations imposed under high pH conditions. Various methods of controlling dilute nutrient solutions for studies at high pH were investigated. For short-term studies, it was found that a solution without Cu, Fe, Mn and Zn and aerated with CO2 depleted air, greatly reduced nutrient precipitation at high pH, thus eliminating nutritional differences between treatments. Manual pH adjustment and the use of ion exchange resins as pH buffers were unsuitable methods of pH control. However, pH control by automated titration had little effect on solution composition while maintaining constant pH. The system described is suitable for studies in which the pH of the bulk nutrient solution must be maintained. The system was used to examine OH- toxicity in mungbeans (Vigna radiata (L.) Wilczek cv. Emerald), with root length reduced at a bulk solution pH of 8.5 and greater.
Resumo:
Business process design is primarily driven by process improvement objectives. However, the role of control objectives stemming from regulations and standards is becoming increasingly important for businesses in light of recent events that led to some of the largest scandals in corporate history. As organizations strive to meet compliance agendas, there is an evident need to provide systematic approaches that assist in the understanding of the interplay between (often conflicting) business and control objectives during business process design. In this paper, our objective is twofold. We will firstly present a research agenda in the space of business process compliance, identifying major technical and organizational challenges. We then tackle a part of the overall problem space, which deals with the effective modeling of control objectives and subsequently their propagation onto business process models. Control objective modeling is proposed through a specialized modal logic based on normative systems theory, and the visualization of control objectives on business process models is achieved procedurally. The proposed approach is demonstrated in the context of a purchase-to-pay scenario.
Resumo:
The dental profession has possessed traditional standards of cross-infection control but the recent expression of real concerns by both the public and the profession over the transmissibility of infectious diseases in the dental surgery has demanded a formalized and extended approach to teaching cross-infection control in the dental curriculum. Clear curriculum content must be formulated within contemporary Workplace Health and Safety Guidelines and the Strategic Plan of the Dental School or academic health centre. The full integration demands that the area is taught as a discrete entity but recognized as an intrinsic part of each clinical encounter. This paper discusses the structure and integration of cross-infection control into the curriculum at the University of Queensland Dental School.
Resumo:
The aim of the study was to test a revised conceptualization of the role of coping in adjustment to a low-control stressor-women's adjustment to a failed in vitro fertilization (NF) attempt. Data were collected prior to the IVF treatment (Time I) and twice after the failed NF attempt (1 to 2 weeks after finding out the results, n = 171, and fi weeks later, n = 139). Initial adjustment was assessed at Time I, whereas measures of coping and both self-report and partner ratings of adjustment were obtained at Times ? and 3. As predicted, escapist strategies and problem-management strategies (mainly at Time ?) were associated with poor adjustment, whereas problem-appraisal coping was associated with better adjustment., There was also support for the proposed positive relationship between adjustment and emotional approach coping (on self-report adjustment).
Resumo:
Control of chaos in the single-mode optically pumped far-infrared (NH3)-N-15 laser is experimentally demonstrated using continuous time-delay control. Both the Lorenz spiral chaos and the detuned period-doubling chaos exhibited by the laser have been controlled. While the laser is in the Lorenz spiral chaos regime the chaos has been controlled both such that the laser output is cw, with corrections of only a fraction of a percent necessary to keep it there, and to period one. The laser has also been controlled while in the period-doubling chaos regime, to both the period-one and -two states.
Resumo:
The present study was designed to examine the main and interactive effects of task demands, work control, and task information on levels of adjustment. Task demands, work control, and task information were manipulated in an experimental setting where participants completed a letter-sorting activity (N = 128). Indicators of adjustment included measures of positive mood, participants' perceptions of task performance, and task satisfaction. Results of the present study provided some support for the main effects of objective task demands, work control, and task information on levels of adjustment. At the subjective level of analysis, there was some evidence to suggest that work control and task information interacted in their effects on levels of adjustment. There was minimal support for the proposal that work control and task information would buffer the negative effects of task demands on adjustment. There was, however, some evidence to suggest that the stress-buffering role of subjective work control was more marked at high, rather than low, levels of subjective task information.
Resumo:
Two species of Antarctic fish were stressed by moving them from seawater at -1 degrees C to seawater at 10 degrees C and holding them for a period of 10 min. The active cryopelagic species Pagothenia borchgrevinki maintained heart rate while in the benthic species Trematomus bernacchii there was an increase in heart rate. Blood pressure did not change in either species. Both species released catecholamines into the circulation as a consequence of the stress. P. borchgrevinki released the greater amounts, having mean plasma concentrations of 177 +/- 54 nmol.l(-1) noradrenaline and 263 +/- 131 nmol.l(-1) adrenaline at 10 min. Pla.sma noradrenaline concentrations rose to 47 +/- 14 nmol.l(-1) and adrenaline to 73 +/- 28 nmol.l(-1) in T. bernacchii. Blood from P. borchgrevinki was tonometered in the presence of isoprenaline. A fall in extracellular pH suggests the presence of a Na+/H+ antiporter on the red cell membrane, the first demonstration of this in an Antarctic fish. Treatment with the beta-adrenergic antagonist drug sotalol inhibited swelling of red blood cells taken from temperature-stressed P. borchgrevinki, suggesting that the antiporter responds to endogenous catecholamines.