39 resultados para Estimator standard error and efficiency


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Methods: Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. Results: The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at greater than or equal to 1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. Conclusions: The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Height, weight, and tissue accrual were determined in 60 male and 53 female adolescents measured annually over six years using standard anthropometry and dual-energy X-ray absorptiometry (DXA). Annual velocities were derived, and the ages and magnitudes of peak height and peak tissue velocities were determined using a cubic spline fit to individual data. Individuals were rank ordered on the basis of sex and age at peak height velocity (PHV) and then divided into quartiles: early (lowest quartile), average (middle two quartiles), and late (highest quartile) maturers. Sex- and maturity-related comparisons in ages and magnitudes of peak height and peak tissue velocities were made. Males reached peak velocities significantly later than females for all tissues and had significantly greater magnitudes at peak. The age at PHV was negatively correlated with the magnitude of PHV in both sexes. At a similar maturity point (age at PHV) there were no differences in weight or fat mass among maturity groups in both sexes. Late maturing males, however, accrued more bone mineral and lean mass and were taller at the age of PHV compared to early maturers. Thus, maturational status (early, average, or late maturity) as indicated by age at PHV is inversely related to the magnitude and late maturers for weight and fat mass in boys and girls. Am. J. Hum. Biol. 13:1-8, 2001. (C) 2001 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A combined procedure for separating Lu, Hf, Sm, Nd, and rare earth elements (REEs) from a single sample digest is presented. The procedure consists of the following five steps: (1) sample dissolution via sodium peroxide sintering; (2) separation of the high field strength elements from the REEs and other matrix elements by a HF-free anion-exchange column procedure; (3) purification of Hf on a cation-exchange resin; (4) separation of REEs from other matrix elements by cation exchange; (5) Lu, Sm, and Nd separation from the other REEs by reversed-phase ion chromatography. Analytical reproducibilities of Sm-Nd and Lu-Hf isotope systematics are demonstrated for standard solutions and international rock reference materials. Results show overall good reproducibilities for Sm-Nd systematics independent of the rock type analyzed. For the Lu-Hf systematics, the reproducibility of the parent/daughter ratio is much better for JB-1 (basalt) than for two analyzed felsic crustal rocks (DR-N and an Archaean granitoid). It is demonstrated that this poorer reproducibility of the Lu/Hf ratio is truly caused by sample heterogeneity; thus, results are geologically reasonable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Theory-of-mind concepts in children with deafness, autism, and normal development (N = 154) were examined in three experiments using a set of standard inferential false-belief tasks and matched sets of tasks involving false drawings. Results of all three experiments replicated previously published findings by showing that primary school children with deafness or autism, aged 6 to 13 years, scored significantly lower than normal-developing 4-year-old preschoolers on standard misleading-container and unseen-change tests of false-belief understanding. Furthermore, deaf and autistic children generally scored higher on drawing-based tests than on corresponding standard tests and, on the most challenging of the false-drawing tests in Experiment 2, they significantly outperformed the normal-developing preschoolers by clearly understanding their own false intentions and another person's false beliefs about an actively misleading drawing. In Experiment 3, preschoolers; outperformed older deaf and autistic children on standard tasks, but did less well on a task that required the drawing of a false belief. Methodological factors could not fully explain the findings, but early social and conversational experiences in the family were deemed likely contributors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thin-layer drying behaviour of bananas in a beat pump dehumidifier dryer was examined. Four pre-treatments (blanching, chilling, freezing and combined blanching and freezing) were applied to the bananas, which were dried at 50 degreesC with an air velocity of 3.1 m s(-1) and with the relative humidity of the inlet air of 10-35%. Three drying models, the simple model, the two-term exponential model and the Page model were examined. All models were evaluated using three statistical measures, correlation coefficient, root means square error, and mean absolute percent error. Moisture diffusivity was calculated based on the diffusion equation for an infinite cylindrical shape using the slope method. The rate of drying was higher for the pre-treatments involving freezing. The sample which was blanched only did not show any improvement in drying rate. In fact, a longer drying time resulted due to water absorption during blanching. There was no change in the rate for the chilled sample compared with the control. While all models closely fitted the drying data, the simple model showed greatest deviation from the experimental results. The two-term exponential model was found to be the best model for describing the drying curves of bananas because its parameters represent better the physical characteristics of the drying process. Moisture diffusivities of bananas were in the range 4.3-13.2 x 10(-10) m(2)s(-1). (C) 2002 Published by Elsevier Science Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low-density lipoprotein oxidation is implicated in the development of atherosclerosis. Plasma susceptibility to oxidation may be used as a marker of low-density lipoprotein oxidation and thus predict atherosclerotic risk. In this study the authors investigated the relationship between plasma susceptibility to oxidation and exposure to automotive pollution in a group of automobile mechanics (n = 16) exposed to high levels of automotive pollution, vs. matched controls (n = 13). The authors induced plasma oxidation by a free radical initiator and they determined susceptibility to oxidation by (1) change in absorbance at 234 nm, (2) lag time to conjugated diene formation, and (3) linear slope of the oxidation curve. Mechanics had significantly higher values (mean standard error) for change in absorbance (1.60 +/- 0.05 vs. 1.36 +/- 0.05; p < .002), and slope (1.6 x 10(-3) +/- 0.1 x 10(-3) vs. 1.3 x 10(-3) +/- 0.1 x 10(-3); p < .001), compared with controls. These results indicate that regular exposure to automotive pollutants increases plasma susceptibility to oxidation and may, in the long term, increase the risk of developing atherosclerosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Purpose. This study evaluated an electromyographic technique for the measurement of muscle activity of the deep cervical flexor (DCF) muscles. Electromyographic signals were detected from the DCF, sternocleidomastoid (SCM), and anterior scalene (AS) muscles during performance of the craniocervical flexion (CCF) test, which involves performing 5 stages of increasing craniocervical flexion range of motion-the anatomical action of the DCF muscles. Subjects. Ten volunteers without known pathology or impairment participated in this study. Methods. Root-mean-square (RMS) values were calculated for the DCF, SCM, and AS muscles during performance of the CCF test. Myoelectric signals were recorded from the DCF muscles using bipolar electrodes placed over the posterior oropharyngeal wall. Reliability estimates of normalized RMS values were obtained by evaluating intraclass correlation coefficients and the normalized standard error of the mean (SEM). Results. A linear relationship was evident between the amplitude of DCF muscle activity and the incremental stages of the CCF test (F=239.04, df=36, P<.0001). Normalized SEMs in the range 6.7% to 10.3% were obtained for the normalized RMS values for the DCF muscles, providing evidence of reliability for these variables. Discussion and Conclusion. This approach for obtaining a direct measure of the DCF muscles, which differs from those previously used, may be useful for the examination of these muscles in future electromyographic applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The left ventricular response to dobutamine may be quantified using tissue Doppler measurement of myocardial velocity or displacement or 3-dimensional echocardiography to measure ventricular volume and ejection fraction. This study sought to explore the accuracy of these methods for predicting segmental and global responses to therapy. Standard dobutamine and 3-dimensional echocardiography were performed in 92 consecutive patients with abnormal left ventricular function at rest. Recovery of function was defined by comparison with follow-up echocardiography at rest 5 months later. Segments that showed improved regional function at follow-up showed a higher increment in peak tissue Doppler velocity with dobutamine therapy than in nonviable segments (1.2 +/- 0.4 vs 0.3 +/- 0.2 cm/s, p = 0.001). Similarly, patients who showed a > 5% improvement of ejection fraction at follow-up showed a greater displacement response to dobutamine (6.9 +/- 3.2 vs 2.1 +/- 2.3 mm, p = 0.001), as well as a higher rate of ejection fraction, response to dobutamine (9 +/- 3% vs 2 +/- 2%, p = 0.001). The optimal cutoff values for predicting subsequent recovery of function at rest were an increment of peak velocity > 1 cm/s, >5 mm of displacement, and a >5% improvement of ejection fraction with low-dose dobutamine. (C) 2003 by Excerpta Medica, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drying kinetics of low molecular weight sugars such as fructose, glucose, sucrose and organic acid such as citric acid and high molecular weight carbohydrate such as maltodextrin (DE 6) were determined experimentally using single drop drying experiments as well as predicted numerically by solving the mass and heat transfer equations. The predicted moisture and temperature histories agreed with the experimental ones within 6% average relative (absolute) error and average difference of +/- 1degreesC, respectively. The stickiness histories of these drops were determined experimentally and predicted numerically based on the glass transition temperature (T-g) of surface layer. The model predicted the experimental observations with good accuracy. A nonsticky regime for these materials during spray drying is proposed by simulating a drop, initially 120 mum in diameter, in a spray drying environment.