131 resultados para Contrast echocardiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To determine the degree of inter-institutional agreement in the assessment of dobutamine stress echocardiograms using modern stress echo cardiographic technology in combination with standardized data acquisition and assessment criteria. Method and Results Among six experienced institutions, 150 dobutamine stress echocardiograms (dobutamine up to 40 mug.kg(-1) min(-1) and atropine up to I mg) were performed on patients with suspected coronary artery disease using fundamental and harmonic imaging following a consistent digital acquisition protocol. Each dobutamine stress echocardiogram was assessed at every institution regarding endocardial visibility and left ventricular wall motion without knowledge of any other data using standardized reading criteria. No patients were excluded due to poor image quality or inadequate stress level. Coronary angiography was performed within 4 weeks. Coronary angiography demonstrated significant coronary artery disease (less than or equal to50% diameter stenosis) in 87 patients. Using harmonic imaging an average of 5.2+/-0.9 institutions agreed on dobutamine stress echocardiogram results as being normal or abnormal (mean kappa 0.55; 95% CI 0.50-0.60). Agreement was higher in patients with no (equal assessment of dobutamine stress echocardiogram results by 5.5 +/- 0.8 institutions) or three-vessel coronary artery disease (5.4 +/- 0.8 institutions) and lower in one- or two- vessel disease (5.0 +/- 0.9 and 5.2 +/- 1.0 institutions, respectively-, P=0.041). Disagreement on test results was greater in only minor wall motion abnormalities. Agreement on dobutamine stress echocardiogram results was lower using fundamental imaging (mean kappa 0.49; 95% CI 0.44-0.54; P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Patients with known or suspected coronary disease are often investigated to facilitate risk assessment. We sought to examine the cost-effectiveness of strategies based on exercise echocardiography and exercise electrocardiography. Methods and results We studied 7656 patients undergoing exercise testing; of whom half underwent exercise echocardiography. Risk was defined with the Duke treadmill score for those undergoing exercise electrocardiography alone, and by the extent of ischaemia by exercise echocardiography. Cox proportional hazards models, risk adjusted for pretest likelihood of coronary artery disease, were used to estimate time to cardiac death or myocardial infarction. Costs (including diagnostic and revascularisation procedures, hospitalisations, and events) were calculated, inflation-corrected to year 2000 using Medicare trust fund rates and discounted at a rate of 5%. A decision model was employed to assess the marginal cost effectiveness (cost/life year saved) of exercise echo compared with exercise electrocardiography. Exercise echocardiography identified more patients as low-risk (51% vs 24%, p<0.001), and fewer as intermediate- (27% vs 51%, p<0.001) and high-risk (22% vs 4%); survival was greater in low- and intermediate- risk and less in high-risk patients. Although initial procedural costs and revascularisation costs (in intermediate- high risk patients) were greater, exercise echocardiography was associated with a greater incremental life expectancy (0.2 years) and a lower use of additional diagnostic procedures when compared with exercise electrocardiography (especially in lower risk patients). Using decision analysis, exercise echocardiography (Euro 2615/life year saved) was more cost effective than exercise electrocardiography. Conclusion Exercise echocardiography may enhance cost-effectiveness for the detection and management of at risk patients with known or suspected coronary disease. (C) 2003 Published by Elsevier Science Ltd on behalf of The European Society of Cardiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of complex plaque morphology on the extent of demand-induced ischemia in unselected patients is not well defined. We sought to investigate the functional significance of lesion morphology in patients who underwent coronary angiography and dobutamine stress echocardiography (DSE).,Angiography and DSE were performed within a 6-month period (mean 1 +/- 1 month) in 196 patients. Angiographic assessments involved quantification of stenosis severity, assessment of the extent of jeopardized myocardium, and categorization of plaque morphology according to the Ambrose classification. DSE was interpreted by separate investigators with respect to wall motion score index (WMSI) and number of coronary territories involved. A general linear model was constructed to assess,the independent contribution of patient characteristics and angiographic and DSE results with respect to extent of ischemic myocardium. Complex lesion morphology was seen in 62 patients (32%). Patients with complex lesions were more likely to have had prior myocardial infarction (p < 0.001) and be current smokers (p = 0.03). During angiography, they exhibited a trend toward a greater number of diseased vessels, had a greater coronary jeopardy score (p < 0.001) and more frequent collateral flow (p = 0.03). During echocardiography, patients had a higher stress WMSI (p < 0.001) and were more likely to show ischemia in all 3 arterial territories (p < 0.01). On multivariate regression, the coronary artery jeopardy score and the presence of complex plaque morphology were independent predictors of the extent of ischemic myocardium (R 2 = 34%, p < 0.001). Thus, patients with complex plaque morphology are older, more likely to smoke, and more likely to have had prior myocardial. infarction. They exhibit more extensive disease with higher coronary jeopardy scores and a higher resting and peak stress WMSI. Despite these differences, complex plaque morphology remains an independent predictor of the extent of ischemia during stress. (C) 2003 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Exercise testing has limited efficacy for identifying coronary artery disease (CAD) in the absence of anginal. symptoms. Exercise echocardiography is more accurate than standard exercise testing, but its efficacy in this situation has not been defined. We sought to identify whether the Duke treadmill. score or exercise echocardiography (ExE) could be used to identify risk in patients without anginal symptoms. Methods We studied 1859 patients without typical or atypical angina, heart failure, or a history or ECG evidence of infarction or CAD, who were referred for ExE, of whom 1832 (age 51 15 years, 944 men) were followed for up to 10 years. The presence and extent of ischaemia and scar were interpreted by expert reviewers at the time of the original study. Results Exercise provoked significant (>0.1 mV) ST segment depression in 215 patients (12%), and wall motion abnormalities in 137 (8%). Seventy-eight patients (4%) died before revascularization, only 17 from known cardiac causes. The independent predictors of death were age (RR 1.1, p

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tissue Doppler imaging allows assessment of left ventricular dyssynchrony and resynchronization after biventricular pacing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coherent Ge(Si)/Si(001) quantum dot islands grown by solid source molecular beam epitaxy at a growth temperature of 700degreesC were investigated using transmission electron microscopy working at 300 kV. The [001] zone-axis bright-field diffraction contrast images of the islands show strong periodicity with the change of the TEM sample substrate thickness and the period is equal to the effective extinction distance of the transmitted beam. Simulated images based on finite element models of the displacement field and using multi-beam dynamical diffraction theory show a high degree of agreement. Studies for a range of electron energies show the power of the technique for investigating composition segregation in quantum dot islands. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES We sought to develop and validate a risk score combining both clinical and dobutamine echocardiographic (DbE) features in 4,890 patients who underwent DbE at three expert laboratories and were followed for death or myocardial infarction for up to five years. BACKGROUND In contrast to exercise scores, no score exists to combine clinical, stress, and echocardiographic findings with DbE. METHODS Dobutamine echocardiography was performed for evaluation of known or suspected coronary artery disease in 3,156 patients at two sites in the U.S. After exclusion of patients with incomplete follow-up, 1,456 DbEs were randomly selected to develop a multivariate model for prediction of events. After simplification of each model for clinical use, the models were internally validated in the remaining DbE patients in the same series and externally validated in 1,733 patients in an independent series. RESULTS The following score was derived from regression models in the modeling group (160 events): DbE risk = (age (.) 0.02) + (heart failure + rate-pressure product <15,000) (.) 0.4 + (ischemia + scar) (.) 0.6. The presence of each variable was scored as 1 and its absence scored as 0, except for age (continuous variable). Using cutoff values of 1.2 and 2.6, patients were classified into groups with five-year event-free survivals >95%, 75% to 95%, and <75%. Application of the score in the internal validation group (265 events) gave equivalent results, as did its application in the external validation group (494 events, C index = 0.72). CONCLUSIONS A risk score based on clinical and echocardiographic data may be used to quantify the risk of events in patients undergoing DbE. (C) 2004 by the American College of Cardiology Foundation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: False-negative interpretations of do-butamine stress echocardiography (DSE) may be associated with reduced wall stress. using measurements of contraction, we sought whether these segments were actually ischemic but unrecognized or showed normal contraction. Methods. We studied 48 patients (29 men; mean age 60 +/- 10 years) with normal regional function on the basis of standard qualitative interpretation of DSE. At coronary angiography within. 6 months of DSE, 32 were identified as having true-negative and 16 as having false-negative results of DSE. Three apical views were used to measure regional function with color Doppler tissue, integrated backscatter, and strain rate imaging. Cyclic variation of integrated backscatter was measured in 16 segments, and strain rate and peak systolic strain was calculated in 6 walls at rest and peak stress. Results. Segments with false-negative results of DSE were divided into 2 groups with and without low wall stress according to previously published cut-off values. Age, sex, left ventricular mass, left ventricular geometric pattern, and peak workload were not significantly different between patients with true and false-negative results of DSE. Importantly, no significant differences in cyclic variation and strain parameters at rest and peak stress were found among segments with true-and false-negative results of DSE with and without low wall stress. Stenosis severity had no influence on cyclic variation and strain parameters at peak stress. Conclusions: False-negative results of DSE reflect lack of ischemia rather than underinterpretation of regional left ventricular function. Quantitative markers are unlikely to increase the sensitivity of DSE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We sought to improve the feasibility of strain rate imaging (SRI) during dobutamine stress echocardiography (DSE) in 56 subjects at low risk of coronary disease. The impact of several SRI changes during acquisition were studied, including: (1) changing from fundamental to harmonic imaging; (2) parallel beam-forming; (3) alteration of spatial resolution and (4) narrow sector acquisition. We assessed SR signal quality, a quantitative measure of signal noise and measurements of SRI. Of 1462 segments evaluated, 6% were uninterpretable at rest and 8% at peak stress. Signal quality was optimised by increasing temporal (p = 0.01) and spatial resolution (p<0.0001 vs. baseline imaging) at rest and peak. Increasing spatial resolution also minimised signal noise (p<0.0001). Inter-observer variability of time to peak SR and peak SR were less with high temporal and spatial resolution. SRI quality can be improved with harmonic imaging and higher temporal resolution but optimisation of spatial resolution is critical. (C) 2004 World Federation for Ultrasound in Medicine Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Subclinical left ventricular (W) dysfunction may be identified by reduced longitudinal contraction. We sought to define the effects of subclinical LV dysfunction on radial contractility in 53 patients with diabetes mellitus with no LV hypertrophy, normal ejection fraction and no ischaemia as assessed by dobutamine echocardiography, in comparison with age-matched controls. Radial peak myocardial systolic velocity (S-m) and early diastolic velocity (E-m), strain and strain rate were measured in the mid-posterior and mid-anteroseptal walls in parasternal views and each variable was averaged for individual patients (radial contractility). These variables were also measured in the mid-posterior and mid-anteroseptal walls in the apical long-axis view and each variable was averaged for individual patients (longitudinal contractility). Mean radial S-m, strain and strain rate were significantly increased in diabetic patients (2.9+/-0.6 cm/s, 28+/-5% and 1.8+/-0.4 s(-1) respectively) compared with controls (2.4+/-0.7 cm/s, 23+/-4% and 1.6+/-0.3 s(-1) respectively; all P<0.001), but there was no difference in E-m (3.3&PLUSMN;1.2 compared with 3.1&PLUSMN;1.1 cm/s, P=not significant). In contrast, longitudinal S-m, E-m, strain and strain rate were significantly lower in diabetic patients (3.6&PLUSMN;1.1 cm/s, 4.3&PLUSMN;1.6 cm/s, 21&PLUSMN;4% and 1.6&PLUSMN;0.3 s(-1) respectively) than in controls (4.3&PLUSMN;1.0 cm/s, 5.7&PLUSMN;2.3 cm/s, 26&PLUSMN;4% and 1.9&PLUSMN;0.3 s(-1) respectively; all P<0.00 1). Thus radial contractility appears to compensate for reduced longitudinal contractility in subclinical LV dysfunction occurring in the absence of ischaemia or LV hypertrophy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES We sought to determine whether assessment of left ventricular (LV) function with real-time (RT) three-dimensional echocardiography (3DE) could reduce the variation of sequential LV measurements and provide greater accuracy than two-dimensional echocardiography (2DE). BACKGROUND Real-time 3DE has become feasible as a standard clinical tool, but its accuracy for LV assessment has not been validated. METHODS Unselected patients (n = 50; 41 men; age, 64 +/- 8 years) presenting for evaluation of LV function were studied with 2DE and RT-3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 h without alteration of hemodynamics or therapy. Magnetic resonance imaging (MRI) images were obtained during a breath-hold, and measurements were made off-line. RESULTS The test-retest variation showed similar measurements for volumes but wider scatter of LV mass measurements with M-mode and 2DE than 3DE. The average MRI end-diastolic volume was 172 +/- 53 ml; LV volumes were underestimated by 2DE (mean difference, -54 +/- 33; p < 0.01) but only slightly by RT-3DE (-4 +/- 29; p = 0.31). Similarly, end-systolic volume by MRI (91 +/- 53 ml) was underestimated by 2DE (mean difference, -28 +/- 28; p < 0.01) and by RT-3DE (mean difference, -3 +/- 18; p = 0.23). Ejection fraction by MRI was similar by 2DE (p = 0.76) and RT-3DE (p = 0.74). Left ventricular mass (183 +/- 50 g) was overestimated by M-mode (mean difference, 68 +/- 86 g; p < 0.01) and 2DE (16 +/- 57; p = 0.04) but not RT-3DE (0 +/- 38 g; p = 0.94). There was good inter- and intra-observer correlation between RT-3DE by two sonographers for volumes, ejection fraction, and mass. CONCLUSIONS Real-time 3DE is a feasible approach to reduce test-retest variation of LV volume, ejection fraction, and mass measurements in follow-up LV assessment in daily practice. (C) 2004 by the American College of Cardiology Foundation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extent of abnormality in patients with positive do-butamine echocardiography (DE) is predictive of risk, but the wall motion score (WMS) has low concordance among observers. We sought whether quantifying the extent of abnormal wall motion using tissue Doppler (TD) could guide risk assessment in patients with abnormal DE in 576 patients with known or suspected coronary artery disease; standard DE was combined with color TD imaging at peak dose. WMS was assessed by an expert observer and studies were identified as abnormal in the presence of 2:1 segments with resting or stress-induced wall motion abnormalities. Patients with abnormal DE had peak systolic velocity measured in each segment. Tissue tracking was used to measure myocardial displacement. Follow-up for death or infarction was per-formed after. 16 +/- 12 months. Of 251 patients with abnormal DE, 22 patients died (20 from cardiac causes) and 7 had nonfatal myocardial infarctionis. The average WMS in patients with events was 1.8 +/- 0.5, compared with 1.7 +/- 0.5 in patients without events (p = NS). The average systolic velocity in patients with events was 4.9 +/- 1.7 cm/s and 6.4 +/- 6.5 cm/s in the patients without events (p <0.001). The average tissue tracking in patients with events was 4.5 +/- 1.5 mm and was significant. (5.7 +/- 3.1 mm),in those,without events (p <0.001). Thus, TD is an alternative to WMS for quantifying the total extent of abnormal left ventricular function-at DE, and appears to be superior for predicting adverse outcomes. (C) 2004 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To determine the diagnostic accuracy of prenatal fetal echocardiography. Methods The study was a retrospective chart review of 190 consecutive patients over a 3-year period from November 1998 to February 2002 of all women referred to the Maternal Fetal Medicine unit, Mater Mothers Hospital, for fetal echocardiography. The prenatal diagnosis was compared with the postnatal diagnosis made by postnatal echocardiography, surgical findings or post-mortem. The accuracy of prenatal diagnosis was described on a predetermined 4-point scale. Results Of the 89 patients, for whom complete diagnostic follow-up was available, there was complete agreement between the prenatal and postnatal diagnosis in 63 cases, minor discrepancies in 25 cases and major disagreement in 1 case. Conclusions In experienced hands, fetal echocardiography is accurate and allows medical staff and patients information in order manage a pregnancy appropriately. Copyright (C) 2004 John Wiley Sons, Ltd.