87 resultados para Concrete Defect Detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship between the ordering characteristic of the pyrochlore structure type and that characteristic of the defect fluorite structure type (immediately on either side of two phase regions separating the two structure types) in a range of rare eath sesquioxide stabilized cubic zirconias is investigated via electron diffraction and imaging. Systematic structural change as a function of composition and relative size of the constituent metal ions is highlighted and a multi-q to single-q = 1/2 [111]* model proposed for the observed pyrochlore to defect fluorite phase transition. Strain introduced into the close-packed {111} metal ion planes of the defect fluorite average structure by the local cation and oxygen vacancy distribution is pointed to as the likely origin of the observed behavior. (C) 2001 Academic Press

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. More than 1300 different mutations in the cystic fibrosis transmembrane conductance regulator (CFTR) cause cystic fibrosis (CF), a disease characterized by deficient epithelial Cl- secretion and enhanced Na+ absorption. The clinical course of the disease is determined by the progressive lung disease. Thus, novel approaches in pharmacotherapy are based primarily on correction of the ion transport defect in the airways. 2. The current therapeutic strategies try to counteract the deficiency in Cl- secretion and the enhanced Na+ absorption. A number of compounds have been identified, such as genistein and xanthine derivatives, which directly activate mutant CFTR. Other compounds may activate alternative Ca2+-activated Cl- channels or basolateral K+ channels, which supply the driving force for Cl- secretion. Apart from that, Na+ channel blockers, such as phenamil and benzamil, are being explored, which counteract the hyperabsorption of NaCl in CF airways. 3. Clinical trials are under way using purinergic compounds such as the P2Y(2) receptor agonist INS365. Activation of P2Y(2) receptors has been found to both activate Cl- secretion and inhibit Na+ absorption. 4. The ultimate goal is to recover Cl- channel activity of mutant CFTR by either enhancing synthesis and expression of the protein or by activating silent CFTR Cl- channels. Strategies combining these drugs with compounds facilitating Cl- secretion and inhibiting Na+ absorption in vivo may have the best chance to counteract the ion transport defect in cystic fibrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. Improved approaches to screening and diagnosis have revealed primary aldosteronism (PAL) to be much more common than previously thought, with most patients normokalaemic. The spectrum of this disorder has been further broadened by the study of familial varieties. 2. Familial hyperaldosteronism type I (FH-I) is a glucocorticoid-remediable form of PAL caused by the inheritance of an adrenocorticotrophic hormone (ACTH)- regulated, hybrid CYP11B1/CYP11B2 gene. Diagnosis has been greatly facilitated by the advent of genetic testing. The severity of hypertension varies widely in FH-I, even among members of the same family, and has demonstrated relationships with gender, degree of biochemical disturbance and hybrid gene crossover point position. Hormone day curve studies show that the hybrid gene dominates over wild-type CYP11B2 in terms of aldosterone regulation. This may be due, in part, to a defect in wild-type CYP11B2-induced aldosterone production. Control of hypertension in FH-I requires only partial suppression of ACTH and much smaller glucocorticoid doses than previously recommended. 3. Familial hyperaldosteronism type II (FH-II) is not glucocorticoid remediable and is not associated with the hybrid gene mutation. Familial hyperaldosteronism type II is clinically, biochemically and morphologically indistinguishable from apparently non-familial PAL. Linkage studies in one informative family did not show segregation of FH-II with the CYP11B2, AT1 or MEN1 genes, but a genome-wide search has revealed linkage with a locus in chromosome 7. As has already occurred in FH-I, elucidation of causative mutations is likely to facilitate earlier detection of PAL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective-To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients. Design-Cohort study. Setting-Regional cardiothoracic unit. Patients-49 patients (mean (SD) age 61 (11) years; 27 women, 22 men) with known or suspected coronary artery disease were studied with simultaneous myocardial contrast echo (MCE) and SPECT after standard dipyridamole stress. Main outcome measures-Regional myocardial perfusion by SPECT, performed with Tc-99m tetrafosmin, scored qualitatively and also quantitated as per cent maximum activity. Results-Normal perfusion was identified by SPECT in 225 of 270 segments (83%). Contrast echo images were interpretable in 92% of patients. The proportion of normal MCE by grey scale, subtracted, and power Doppler techniques were respectively 76%, 74%, and 88% (p < 0.05) at > 80% of maximum counts, compared with 65%, 69%, and 61% at < 60% of maximum counts. For each technique, specificity was lowest in the lateral wail, although power Doppler was the least affected. Grey scale and subtraction techniques were least accurate in the septal wall, but power Doppler showed particular problems in the apex. On a per patient analysis, the sensitivity was 67%, 75%, and 83% for detection of coronary artery disease using grey scale, colour coded, and power Doppler, respectively, with a significant difference between power Doppler and grey scale only (p < 0.05). Specificity was also the highest for power Doppler, at 55%, but not significantly different from subtracted colour coded images. Conclusions-Myocardial contrast echo using harmonic power Doppler has greater accuracy than with grey scale imaging and digital subtraction. However, power Doppler appears to be less sensitive for mild perfusion defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concerns have been raised about the reproducibility of brachial artery reactivity (BAR), because subjective decisions regarding the location of interfaces may influence the measurement of very small changes in lumen diameter. We studied 120 consecutive patients with BAR to address if an automated technique could be applied, and if experience influenced reproducibility between two observers, one experienced and one inexperienced. Digital cineloops were measured automatically, using software that measures the leading edge of the endothelium and tracks this in sequential frames and also manually, where a set of three point-to-point measurements were averaged. There was a high correlation between automated and manual techniques for both observers, although less variability was present with expert readers. The limits of agreement overall for interobserver concordance were 0.13 +/-0.65 mm for the manual and 0.03 +/-0.74 mm for the automated measurement. For intraobserver concordance, the limits of agreement were -0.07 +/-0.38 mm for observer 1 and -0.16 +/-0.55 mm for observer 2. We concluded that BAR measurements were highly concordant between observers, although more concordant using the automated method, and that experience does affect concordance. Care must be taken to ensure that the same segments are measured between observers and serially.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An increasingly comprehensive assessment is being developed of the extent and potential significance of lateral gene transfer among microbial genomes. Genomic sequences can be identified as being of putatively lateral origin by their unexpected phyletic distribution, atypical sequence composition, differential presence or absence in closely related genomes, or incongruent phylogenetic trees. These complementary approaches sometimes yield inconsistent results. Not only more data but also quantitative models and simulations are needed urgently.