33 resultados para 6~9 ka BP
Resumo:
OBJECTIVES We sought to use quantitative markers of the regional left ventricular (LV) response to stress to infer whether diabetic cardiomyopathy is associated with ischemia. BACKGROUND Diabetic cardiomyopathy has been identified in clinical and experimental studies, but its cause remains unclear. METHODS We studied 41 diabetic patients with normal resting LV function and a normal dobutamine echo and 41 control subjects with a low probability of coronary disease. Peak myocardial systolic velocity (Sm) and early diastolic velocity (Em) in each segment were averaged, and mean Sm and Em were compared between diabetic patients and controls and among different stages of dobutamine stress. RESULTS Both Sm and Em progressively increased from rest to peak dobutamine stress. In the diabetic group, Sm was significantly lower than in control subjects at baseline (4.2 +/- 0.9 cm/s vs. 4.7 +/- 0.9 cm/s, p = 0.012). However, Sin at a low dose (6.0 +/- 1.3), before peak (8.4 +/- 1.8), and at peak stress (8.9 +/- 1.8) in diabetic patients was not significantly different from that of controls (6.3 +/- 1.4, 8.9 +/- 1.6, and 9.6 +/- 2.1 cm/s, respectively). The Em (cm/s) in the diabetic group (rest: 4.2 +/- 1.2; low dose: 5.0 +/- 1.4; pre-peak: 5.3 +/- 1.1; peak: 5.9 +/- 1.5) was significantly lower than that of controls (rest: 5.8 +/- 1.5; low dose: 6.6 +/- 1.5; pre-peak: 6.9 +/- 1.3; peak: 7.3 +/- 1.7; all p < 0.001). However, the absolute and relative increases in Sm or Em from rest to peak stress were similar in diabetic and control groups. CONCLUSIONS Subtle LV dysfunction is present in diabetic patients without overt cardiac disease. The normal response to stress suggests that ischemia due to small-vessel disease may not be important in early diabetic heart muscle disease. (C) 2003 by the American College of Cardiology Foundation.
Resumo:
The left ventricular response to dobutamine may be quantified using tissue Doppler measurement of myocardial velocity or displacement or 3-dimensional echocardiography to measure ventricular volume and ejection fraction. This study sought to explore the accuracy of these methods for predicting segmental and global responses to therapy. Standard dobutamine and 3-dimensional echocardiography were performed in 92 consecutive patients with abnormal left ventricular function at rest. Recovery of function was defined by comparison with follow-up echocardiography at rest 5 months later. Segments that showed improved regional function at follow-up showed a higher increment in peak tissue Doppler velocity with dobutamine therapy than in nonviable segments (1.2 +/- 0.4 vs 0.3 +/- 0.2 cm/s, p = 0.001). Similarly, patients who showed a > 5% improvement of ejection fraction at follow-up showed a greater displacement response to dobutamine (6.9 +/- 3.2 vs 2.1 +/- 2.3 mm, p = 0.001), as well as a higher rate of ejection fraction, response to dobutamine (9 +/- 3% vs 2 +/- 2%, p = 0.001). The optimal cutoff values for predicting subsequent recovery of function at rest were an increment of peak velocity > 1 cm/s, >5 mm of displacement, and a >5% improvement of ejection fraction with low-dose dobutamine. (C) 2003 by Excerpta Medica, Inc.
Resumo:
This study reports on a block clinical trial of two types of central venous catheters (CVCs): antiseptic-impregnated catheters (AIC) and non-impregnated catheters (non-AIC), on catheter tip colonization and bacteraemia. In total, 500 catheters were inserted in 390 patients over the 18 month study period, 260 (52.0%) AIC and 240 (48.0%) non-AIC. Of these, 460 (92.0%) tips (237 AIC and 223 non-AIC) were collected. While significantly fewer AIC, 14 (5.9%), than non-AIC, 30 (13.5%), catheters were colonized (P < 0.01), there was no difference in the rates of bacteraemias in the two groups (0.8% vs. 2.7%, respectively, P = 0.16). There were 6.87 (95% CI 3.38-14.26) and 16.92 (95% CI 10.61-27.12) colonized AIC and non-AIC catheters, respectively, per 1000 catheter days, a difference that was significant (P < 0.01). However, no difference emerged between bacteraemias in AIC and non-AIC catheters per 1000 catheter days measured at 0.98 (95% CI 0.24-5.54) and 3.38 (95% CI 1.29-9.34), respectively (P = 0.10). Of the 444 CVCs that were sited in the subclavian or jugular veins and had tips collected, significantly more catheters were colonized in the jugular group, 19 (20%), compared with the subclavian group, 24 (6.9%; P less than or equal to 0.01). Overall, the low rates of colonization and bacteraemia may be explained by the population studied, the policies used and the employment of a clinical nurse dedicated to CVC management. (C) 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.