103 resultados para vacuum-pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant loss in electron probe current can occur before the electron beam enters the specimen chamber of an environmental scanning electron microscope (ESEM). This loss results from electron scattering in a gaseous jet formed inside and downstream (above) the pressure-limiting aperture (PLA), which separates the high-pressure and high-vacuum regions of the microscope. The electron beam loss above the PLA has been calculated for three different ESEMs, each with a different PLA geometry: an ElectroScan E3, a Philips XL30 ESEM, and a prototype instrument. The mass thickness of gas above the PLA in each case has been determined by Monte Carlo simulation of the gas density variation in the gas jet. It has been found that the PLA configurations used in the commercial instruments produce considerable loss in the electron probe current that dramatically degrades their performance at high chamber pressure and low accelerating voltage. These detrimental effects are minimized in the prototype instrument, which has an optimized thin-foil PLA design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vacuum gamma -radiolysis of two fluorinated polyimides containing phenylphosphine oxide units, TOR-RC and TOR-RC ODPA, have been studied at 77 K and 300 K. The phenyl phosphine oxide units provide protection of the polymers towards oxidation by oxygen atoms and the bulky fluoromethyl groups reduce the colouration of the polymers by limiting donor-acceptor complex formation through the aromatic units. At 77 K the radicals formed were identified to be a mixture of neutral radicals (60%) and anion radicals. At 300 K only neutral radicals were found. The G-values for radical formation were found to be 0.50 and 0.42 at 77 K and 0.051 and 0.052 at 300 K for TOR-RC and TOR-RC ODPA, respectively. Little change was observed in the visible spectra of the polyimides following vacuum radiolysis at 300 K up to a dose of 3.3 MGy, and the polymers were shown to undergo net cross linking with a gel dose of 0.45 MGy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flash vacuum thermolysis of a large variety of heterocyclic compounds is a useful means of production of ketenes, ketenimines, thioketenes, allenes, iminopropadienones, bis(imino)propadienes, iminopropadienethiones, carbodiimides, isothiocyanates, acetylenes, fulminic acid, nitrile imines and nitrile ylides, nitriles, cyanamides, cyanates, and other compounds, often in preparatively useful yields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that by making conditional measurements on the Einstein-Podolsky-Rosen (EPR) squeezed vacuum [T. Opatrny, G. Kurizki, and D.-G. Welsch, Phys. Rev. A 61, 032302 (2000)], one can improve the efficacy of teleportation for both the position-difference, momentum-sum, and number-difference, phase-sum continuous variable teleportation protocols. We investigate the relative abilities of the standard and conditional EPR states, and show that by conditioning we can improve the fidelity of teleportation of coherent states from below to above the (F) over bar =2/3 boundary, thereby achieving unambiguously quantum teleportation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show how polarization measurements on the output fields generated by parametric down conversion will reveal a violation of multiparticle Bell inequalities, in the regime of both low- and high-output intensity. In this case, each spatially separated system, upon which a measurement is performed, is comprised of more than one particle. In view of the formal analogy with spin systems, the proposal provides an opportunity to test the predictions of quantum mechanics for spatially separated higher spin states. Here the quantum behavior possible even where measurements are performed on systems of large quantum (particle) number may be demonstrated. Our proposal applies to both vacuum-state signal and idler inputs, and also to the quantum-injected parametric amplifier as studied by De Martini The effect of detector inefficiencies is included, and weaker Bell-Clauser-Horne inequalities are derived to enable realistic tests of local hidden variables with auxiliary assumptions for the multiparticle situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural changes which occur on the gamma -radiolysis of poly(dimethyl siloxane) (PDMS) under vacuum at 303 K have been investigated using Si-29 and C-13 NMR. New structural units consistent with main chain scission and crosslinking through both H-linking and Y-linking reactions have been identified. The results obtained at various absorbed doses have been used to calculate the G-values for scission and crosslinking. G-values for scission of G(S) = 1.3 +/- 0.2, for H-linking of G(D-CH2-R) = 0.34 +/- 0.02 and for Y-Linking of G(Y) = 1.70 +/- 0.09 were obtained for radiolysis under vacuum at 303 K. Thus crosslinking predominates over scission for radiolysis of PDMS under these conditions, and, by contrast with previous studies, Y-links have been shown to be the predominant form of crosslinks. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate an optical scheme to conditionally engineer quantum states using a beam splitter, homodyne detection, and a squeezed vacuum as an ancillar state. This scheme is efficient in producing non-Gaussian quantum states such as squeezed single photons and superpositions of coherent states (SCSs). We show that a SCS with well defined parity and high fidelity can be generated from a Fock state of n

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current evidence supports parenteral infusion of proton pump inhibitors (PPI) after endoscopic treatment of bleeding peptic ulcers and such treatment seems reasonable where there is active bleeding or visible vessel on endoscopy. Parenteral boluses of PPI can be used in patients nil by mouth who cannot tolerate oral therapy. We sought to examine the appropriateness of parenteral PPI use. Drug utilisation evaluation was performed on 94 patients admitted to a 500 bed metropolitan hospital. 39 patients received continuous parenteral infusion of omeprazole (8 mg/ h) over a mean of 60 ± 29 h. 55 patients had parenteral boluses (40 mg bd) of omeprazole over a mean of 5 ± 4 days. Indications for PPI infusion (n = 39) were: major haemorrhage requiring transfusion (23), minor haemorrhage (8), dyspepsia (4) and others (4). 31 of the 39 patients on PPI infusion had upper gastrointestinal (GI) endoscopy. PPI infusion was commenced prior to endoscopy in 26 (84%) patients. 13 patients (33%) had active bleeding or visible non bleeding vessels at endoscopy. Only 11 patients (28%) had endoscopically treated peptic ulcers. Indications for parenteral PPI boluses (n = 55) included patients nil by mouth unable to take maintenance PPI orally (21), minor haemorrhage (8), peptic ulcer prophylaxis in seriously unwell (6), major haemorrhage (4), dyspepsia (2), postoprative period following peptic ulcer surgery (2) and others (12). Endoscopy was performed in 10 patients (18%) with only 1 endoscopically treated peptic ulcer. Our data suggest significant inappropriate use of parenteral PPI, which may be used for minor GI bleeding and dyspepsia and are typically commenced prior to endoscopy. These findings can explain the costly hospital expenditure on PPI.