Resumo:
Abnormal left ventricular (LV) filling is common, but not universal, in hypertensive LV hypertrophy (LVH). We sought to elucidate the relative contributions of myocardial structural changes, loading and hypertrophy to LV dysfunction in 113 patients: 85 with hypertensive LVH and 28 controls without LVH and with normal filling. Patients with normal dobutamine stress echocardiography and no history of coronary artery disease were selected, in order to exclude a contribution from ischaemia or scar. Abnormal LV filling was identified in 65 LVH patients, based on Doppler measurement of transmitral filling and annular velocities. All patients underwent grey-scale and colour tissue Doppler imaging from three apical views, which were stored and analysed off line. Integrated backscatter (113) and strain rate imaging were used to detect changes in structure and function; average cyclic variation of 113, strain rate and peak systolic strain were calculated by averaging each segment. Calibrated 113 intensity, corrected for pericardial 113 intensity, was measured in the septum and posterior wall from the parasternal long-axis view. Patients with LVH differed significantly from controls with respect to all backscatter and strain parameters, irrespective of the presence or absence of abnormal LV filling. LVH patients with and without abnormal LV filling differed with regard to age, LV mass and incidence of diabetes mellitus, but also showed significant differences in cyclic variation (P < 0.01), calibrated 113 in the posterior wall (P < 0.05) and strain rate (P < 0.01), although blood pressure, heart rate and LV systolic function were similar. Multivariate logistic regression analysis demonstrated that age, LV mass index and calibrated IB in the posterior wall were independent determinants of abnormal LV filling in patients with LVH. Thus structural and functional abnormalities can be detected in hypertensive patients with LVH with and without abnormal LV filling. In addition to age and LVH, structural (not functional) abnormalities are likely to contribute to abnormal LV filling, and may be an early sign of LV damage. 113 is useful for the detection of myocardial abnormalities in patients with hypertensive LVH.
Resumo:
Objectives To assess the detection rate of congenital fetal malformations and specific problems related to routine ultrasound screening in women with pre-existing diabetes. Methods A retrospective study was carried out to assess the performance of routine ultrasound screening in women with pre-existing diabetes (Types 1 and 2) within a tertiary institution. The incidence, type and risk factors for congenital fetal malformations were determined. The detection rate of fetal anomalies for diabetic women was compared with that for the low-risk population. Factors affecting these detection rates were evaluated. Results During the study period, 12 169 low-risk pregnant women and 130 women with pre-existing diabetes had routine ultrasound screening performed within the institution. A total of 10 major anomalies (7.7%) and three minor anomalies (2.3%) were present in the fetuses of the diabetic women. Central nervous system and cardiovascular system anomalies accounted for 60% of the major anomalies. Peri-conceptional hemoglobin A 1 c of more than 9% was associated with a high prevalence of major anomalies (14311000). Women who had fetuses with major anomalies bad a significantly higher incidence of obesity (78% vs. 37%; P < 0.05). Ultrasound examination of these diabetic pregnancies showed high incidences of suboptimal image quality (37%), incomplete examinations, and repeat examinations (17%). Compared to the 'low-risk' non-diabetic population from the same institution, the relative risk for a major congenital anomaly among the diabetic women was 5.9-fold higher (95% confidence interval, 2.9-11.9). The detection rate for major fetal anomalies was significantly lower for diabetic women (30% vs. 73%; P < 0.01), and the mean body mass index for the diabetic group was significantly higher (29 vs. 23 kg/m(2); P < 0.001). Conclusion The incidence of congenital anomalies is higher in diabetic pregnancies. Unfortunately, the detection rate for fetal anomalies by antenatal ultrasound scan was significantly, worse than that for the low-risk population. This is likely to be related to the maternal body habitus and unsatisfactory examinations. Methods to overcome these difficulties are discussed.
Resumo:
We compared the quality of realtime fetal ultrasound images transmitted using ISDN and IP networks. Four experienced obstetric ultrasound specialists viewed standard recordings in a randomized trial and rated the appearance of 30 fetal anatomical landmarks, each on a seven-point scale. A total of 12 evaluations were performed for various combinations of bandwidths (128, 384 or 768 kbit/s) and networks (ISDN or IF). The intraobserver coefficient of variation was 2.9%, 5.0%, 12.7% and 14.7% for the four observers. The mean overall ratings by each of the four observers were 4.6, 4.8, 5.0 and 5.3, respectively (a rating of 4 indicated satisfactory visualization and 7 indicated as good as the original recording). Analysis of variance showed that there were no significant interobserver variations nor significant differences in the mean scores for the different types of videoconferencing machines used. The most significant variable affecting the mean score was the bandwidth used. For ISDN, the mean score was 3.7 at 128 kbit/s, which was significantly worse than the mean score of 4.9 at 384 kbit/s, which was in turn significantly worse than the mean score of 5.9 at 768 kbit/s. The mean score for transmission using IP was about 0.5 points lower than that using ISDN across all the different bandwidths, but the differences were not significant. It appears that IP transmission in a private (non-shared) network is an acceptable alternative to ISDN for fetal tele-ultrasound and one deserving further study.
Resumo:
Objectives. This study aimed to determine the incidence of abdominal aortic aneurysm (AAA) in a large group of siblings of Australian AAA patients to determine if screening in this group is justified. Methods. 1254 siblings of 400 index AAA patients were identified and offered aortic ultrasound screening. An age and sex matched control group was recruited from patients having abdominal CT scans for non-vascular indications. AAA was defined by an infrarenal aortic diameter of greater than or equal to3 cm or a ratio of the infrarenal to suprarenal aortic diameter of greater than or equal to2.0. A ratio of 1.0-1.5 was considered normal, and a ratio of >1.5 to
Resumo:
To investigate the ability of ultrasonography to estimate musactivity, we measured architectural parameters (pennation angles, fascicle lengths, and muscle thickness) of several human muscles (tibialis anterior, biceps brachii, brachialis, transversus abdominis, obliquus internus abdominis, and obliquus externus abdominis) during isometric contractions of from 0 to 100% maximal voluntary contraction (MVC). Concurrently, electromyographic (EMG) activity was measured with surface (tibialis anterior only) or fine-wire electrodes. Most architectural parameters changed markedly with contractions up to 30% MVC but changed little at higher levels of contraction. Thus, ultrasound imaging can be used to detect low levels of muscle activity but cannot discriminate between moderate and strong contractions. Ultrasound measures could reliably detect changes in EMG of as little as 4% MVC (biceps muscle thickness), 5% MVC (brachialis muscle thickness), or 9% MVC (tibialis anterior pennation angle). They were generally less sensitive to changes in abdominal muscle activity, but it was possible to reliably detect contractions of 12% MVC in transversus abdominis (muscle length) and 22% MVC in obliquus internus (muscle thickness). Obliquus externus abdominis thickness did not change consistently with muscle contraction, so ultrasound measures of thickness cannot be used to detect activity of this muscle. Ultrasound imaging can thus provide a non-invasive method of detecting isometric muscle contractions of certain individual muscles.
Resumo:
Background and aims: Hip fracture is a devastating event in terms of outcome in the elderly, and the best predictor of hip fracture risk is hip bone density, usually measured by dual X-ray absorptiometry (DXA). However, bone density can also be ascertained from computerized tomography (CT) scans, and mid-thigh scans are frequently employed to assess the muscle and fat composition of the lower limb. Therefore, we examined if it was possible to predict hip bone density using mid-femoral bone density. Methods: Subjects were 803 ambulatory white and black women and men, aged 70-79 years, participating in the Health, Aging and Body Composition (Health ABC) Study. Bone mineral content (BMC, g) and volumetric bone mineral density (vBMD, mg/cm(3)) of the mid-femur were obtained by CT, whereas BMC and areal bone mineral density (aBMD, g/cm(2)) of the hip (femoral neck and trochanter) were derived from DXA. Results: In regression analyses stratified by race and sex, the coefficient of determination was low with mid-femoral BMC, explaining 6-27% of the variance in hip BMC, with a standard error of estimate (SEE) ranging from 16 to 22% of the mean. For mid-femur vBMD, the variance explained in hip aBMD was 2-17% with a SEE ranging from 15 to 18%. Adjusting aBMD to approximate volumetric density did not improve the relationships. In addition, the utility of fracture prediction was examined. Forty-eight subjects had one or more fractures (various sites) during a mean follow-up of 4.07 years. In logistic regression analysis, there was no association between mid-femoral vBMD and fracture (all fractures), whereas a 1 SD increase in hip BMD was associated with reduced odds for fracture of similar to60%. Conclusions: These results do not support the use of CT-derived mid-femoral vBMD or BMC to predict DXA-measured hip bone mineral status, irrespective of race or sex in older adults. Further, in contrast to femoral neck and trochanter BMD, mid-femur vBMD was not able to predict fracture (all fractures). (C) 2003, Editrice Kurtis.