48 resultados para tablet devices
Resumo:
Aims The major aims of the study were to compare the safety of a continuous low-dose estradiol-releasing vaginal ring (ESTring) to that of a vaginal estradiol tablet (Vagifem®) on the endometrium and the relief of subjective symptoms and signs of urogenital estrogen deficiency. Quality of life and acceptability of treatment delivery were also assessed. Study design A prospective, randomized study in which women were assigned in a 2: 1 ratio to ESTring and Vagifem and followed for 12 months. The primary endpoint was endometrial safety, based on the results of ultrasound measurement of endometrial thickness and a progestogen challenge test at baseline and week 48. Efficacy was determined by subjective assessment of urogenital estrogen deficiency symptoms at baseline and weeks 3, 12, 24, 36 and 48 and assessment of signs of vaginal epithelial atrophy by the clinician at baseline, 12 and 48 weeks. In addition, pelvic floor strength, vaginal cytological evaluation and pH, bacteruria and patient acceptability were assessed. Quality of life was assessed using a menopause-specific quality-of-life questionnire and a 2-day bladder diary at baseline and 12 and 48 weeks. The comparability of the two groups was assessed using ANOVA, χ(2) or Fisher's exact tests. Results A total of 126 women were randomized to ESTring and 59 to Vagifem. There was no statistical difference between the groups in the alleviation of symptoms and signs of urogenital estrogen deficiency. Maturation indices increased in both groups, from generally atrophic at baseline to proliferative or highly proliferative at 48 weeks. After 48 weeks of treatment, there was no statistically significant difference in endometrial thickness between the two groups. A statistically smaller proportion of bleeding/spotting occurred in the ESTring group (n = 0) compared to the Vagifem users (n = 4). Estradiol and total estrone serum levels increased during treatment in both groups but remained within the normal postmenopausal range. General health status in both groups was unchanged but the urogenital component of health burden was significantly improved in both groups. Bladder diary variables showed no differences between treatment groups. Conclusion Equivalent endometrial safety and efficacy in the relief of the symptoms and signs of urogenital estrogen deficiency were demonstrated for the 12 months' use of a low-dose estradiol-releasing vaginal ring and a vaginal estradiol tablet.
Resumo:
Echinacea is a widely used herbal remedy for the treatment of colds and other infections. However, almost nothing is known about the disposition and pharmacokinetics of any of its components, particularly the alkamides and caffeic acid conjugates which are thought to be the active phytochemicals. In this investigation, we have examined serial plasma samples from 9 healthy volunteers who ingested echinacea tablets manufactured from ethanolic liquid extracts of Echinacea angustifolia and Echinacea purpurea immediately after a standard high fat breakfast. Caffeic acid conjugates could not be identified in any plasma sample at any time after tablet ingestion. Alkamides were rapidly absorbed and were measurable in plasma 20 min after tablet ingestion and remained detectable for up to 12 h. Concentration-time curves for 2,4-diene and 2-ene alkamides were determined. The maximal concentrations for the sum of alkamides in human plasma were reached within 2.3 h post ingestion and averaged 336 +/- 131 ng eq/mL plasma. No obvious differences were observed in the pharmacokinetics of individual or total alkamides in 2 additional fasted subjects who took the same dose of the echinacea preparation. This single dose study provides evidence that alkamides are orally available and that their pharmacokinetics are in agreement with the one dose three times daily regimen already recommended for echinacea.
Resumo:
We introduce a spin-charge conductance matrix as a unifying concept underlying charge and spin transport within the framework of the Landauer-Buttiker conductance formula. It turns out that the spin-charge conductance matrix provides a natural and gauge covariant description for electron transport through nanoscale electronic devices. We demonstrate that the charge and spin conductances are gauge invariant observables which characterize transport phenomena arising from spin-dependent scattering. Tunnelling through a single magnetic atom is discussed to illustrate our theory.
Resumo:
Geometric phases of scattering states in a ring geometry are studied on the basis of a variant of the adiabatic theorem. Three timescales, i.e., the adiabatic period, the system time and the dwell time, associated with adiabatic scattering in a ring geometry play a crucial role in determining geometric phases, in contrast to only two timescales, i.e., the adiabatic period and the dwell time, in an open system. We derive a formula connecting the gauge invariant geometric phases acquired by time-reversed scattering states and the circulating (pumping) current. A numerical calculation shows that the effect of the geometric phases is observable in a nanoscale electronic device.
Resumo:
Information security devices must preserve security properties even in the presence of faults. This in turn requires a rigorous evaluation of the system behaviours resulting from component failures, especially how such failures affect information flow. We introduce a compositional method of static analysis for fail-secure behaviour. Our method uses reachability matrices to identify potentially undesirable information flows based on the fault modes of the system's components.
Resumo:
Electron-multiplying charge coupled devices promise to revolutionize ultrasensitive optical imaging. The authors present a simple methodology allowing reliable measurement of camera characteristics and statistics of single-electron events, compare the measurements to a simple theoretical model, and report camera performance in a truly photon-counting regime that eliminates the excess noise related to fluctuations of the multiplication gain.
Resumo:
Communications devices for government or military applications must keep data secure, even when their electronic components fail. Combining information flow and risk analyses could make fault-mode evaluations for such devices more efficient and cost-effective.
Resumo:
Protein molecular motors, which are natural nano-machines that convert the chemical energy into mechanical work for cellular motion, muscle contraction and cell division, have been integrated in the last decade in primitive nanodevices based on the motility of nano-biological objects in micro- and nano-fabricated structures. However, the motility of microorganisms powered by molecular motors has not been similarly exploited. Moreover, among the proposed devices based on molecular motors, i.e., nanosensors, nano-mechanical devices and nano-imaging devices, biocomputation devices are conspicuously missing. The present contribution discusses, based on the present state of the art nano- and micro-fabrication, the comparative advantages and disadvantages of using nano- and micro-biological objects in future computation devices. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
This study presents results from an experimental 10-day research charter that was designed to quantify the effects of (a) a turtle excluder device (TED), (b) a radial escape section bycatch reduction device (BRD) and (c) both devices together, on bycatch and prawn catch rates in the Queensland shallow water eastern king prawn (Penaeus plebejus) trawl fishery. The bycatch was comprised of 250 taxa, mainly gurnards, whiting, lizard fish, flathead, dragonets, portunid crabs, turretfish and flounders. The observed mean catch rates of bycatch and marketable eastern king prawns from the standard trawl net (i.e., net with no TED or BRD) used during the charter were 11.06 kg/hectare (ha(-1)) (S.E. 0.90) swept by the trawl gear and 0.94 kg ha(-1), respectively. For the range of depths sampled (20.1-90.7 m), bycatch rates declined significantly at a rate of 0.14 kg ha-1 for every 1 m increase in depth, while prawn catch rates were unaffected. When both the TED and radial escape section BRD were used together, the bycatch rate declined by 24% compared to a standard net, but at a 20% reduction in marketable prawn catch rate. The largest reductions were achieved for stout whiting Sillago robusta (57% reduction) and yellowtail scad Trachurus novaezelandiae (32% reduction). Multidimensional scaling and analysis of similarities revealed that bycatch assemblages differed significantly between depths and latitude, but not between the different combinations of bycatch reduction devices. Despite the lowered prawn catch rates, the reduced bycatch rates are promising, particularly for S. robusta, which is targeted in another fishery. Prawn trawl operators are not permitted to retain S. robusta and the devices examined herein offer the potential to significantly reduce the incidental fishing mortality that this species experiences. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
The ability to control the surface properties and subsequent colloidal stability of dispersed particles has widespread applicability in many fields. Sub-micrometer fluorescent silica particles (reporters) can be used to actively encode the combinatorial synthesis of peptide libraries through interparticle association. To achieve these associations, the surface chemistry of the small fluorescent silica reporters is tailored to encourage robust adhesion to large silica microparticles onto which the peptides are synthesized. The interparticle association must withstand a harsh solvent environment multiple synthetic and washing procedures, and biological screening buffers. The encoded support beads were exposed to different solvents used for peptide synthesis, and different solutions used for biological screening including phosphate buffered saline (PBS), 2-[N-morpholino]ethane sulfonic acid (VIES) and a mixture of MES and N-(3-dimethyl-aminopropyl)-N'-ethylcarbodiimide (EDC). The number of reporters remaining adhered to the support bead was quantified after each step. The nature of the associations were explored and tested to optimize the efficiency of these phenomena. Results presented illustrate the influence of the surface functionality and polyelectrolyte modification of the reporters. These parameters were investigated through zeta potential and X-ray photoelectron spectroscopy.
Resumo:
Since 1994, Canada, the United Kingdom and Australia have adopted new choice of law rules for cross-border torts that, in different ways, centre on the application of the law of the place where the tort occurred (the lex loci delicti). All three countries abandoned some species of the rule in Phillips v Eyre, which required some reference to the law of the forum (the lex fori) as well as the lex loci delicti. However, predictions were made that, where possible, courts in these countries would continue to show a strong inclination to apply the lex fori in cross-border tort cases - and would use a range of homing devices to do so. A comprehensive survey and analysis of the cases that have been decided under the Australian, British and Canadian lex loci delicti regimes suggests that courts in these countries do betray a homing instinct, but one that has actually been tightly restrained by appeal courts. Where application of the lex fori was formally allowed by use of a 'flexible exception' in Canada and the United Kingdom, this has been contained by courts of first appeal. Indeed, only the continuing characterization of the assessment of damages as a procedural question in Canada and the United Kingdom, seems to remain as a significant homing device for courts in these countries. © 2006 Oxford University Press.
Resumo:
Online multimedia data needs to be encrypted for access control. To be capable of working on mobile devices such as pocket PC and mobile phones, lightweight video encryption algorithms should be proposed. The two major problems in these algorithms are that they are either not fast enough or unable to work on highly compressed data stream. In this paper, we proposed a new lightweight encryption algorithm based on Huffman error diffusion. It is a selective algorithm working on compressed data. By carefully choosing the most significant parts (MSP), high performance is achieved with proper security. Experimental results has proved the algorithm to be fast. secure: and compression-compatible.