23 resultados para nonelective percutaneous


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To develop an appropriate dosing strategy for continuous intravenous infusions (CII) of enoxaparin by minimizing the percentage of steady-state anti-Xa concentration (C-ss) outside the therapeutic range of 0.5-1.2 IU ml(-1). Methods A nonlinear mixed effects model was developed with NONMEM (R) for 48 adult patients who received CII of enoxaparin with infusion durations that ranged from 8 to 894 h at rates between 100 and 1600 IU h(-1). Three hundred and sixty-three anti-Xa concentration measurements were available from patients who received CII. These were combined with 309 anti-Xa concentrations from 35 patients who received subcutaneous enoxaparin. The effects of age, body size, height, sex, creatinine clearance (CrCL) and patient location [intensive care unit (ICU) or general medical unit] on pharmacokinetic (PK) parameters were evaluated. Monte Carlo simulations were used to (i) evaluate covariate effects on C-ss and (ii) compare the impact of different infusion rates on predicted C-ss. The best dose was selected based on the highest probability that the C-ss achieved would lie within the therapeutic range. Results A two-compartment linear model with additive and proportional residual error for general medical unit patients and only a proportional error for patients in ICU provided the best description of the data. Both CrCL and weight were found to affect significantly clearance and volume of distribution of the central compartment, respectively. Simulations suggested that the best doses for patients in the ICU setting were 50 IU kg(-1) per 12 h (4.2 IU kg(-1) h(-1)) if CrCL < 30 ml min(-1); 60 IU kg(-1) per 12 h (5.0 IU kg(-1) h(-1)) if CrCL was 30-50 ml min(-1); and 70 IU kg(-1) per 12 h (5.8 IU kg(-1) h(-1)) if CrCL > 50 ml min(-1). The best doses for patients in the general medical unit were 60 IU kg(-1) per 12 h (5.0 IU kg(-1) h(-1)) if CrCL < 30 ml min(-1); 70 IU kg(-1) per 12 h (5.8 IU kg(-1) h(-1)) if CrCL was 30-50 ml min(-1); and 100 IU kg(-1) per 12 h (8.3 IU kg(-1) h(-1)) if CrCL > 50 ml min(-1). These best doses were selected based on providing the lowest equal probability of either being above or below the therapeutic range and the highest probability that the C-ss achieved would lie within the therapeutic range. Conclusion The dose of enoxaparin should be individualized to the patients' renal function and weight. There is some evidence to support slightly lower doses of CII enoxaparin in patients in the ICU setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An increasing number of formulations are applied to equine skin, yet variable penetration can affect efficacy, or the incidence of adverse effects, or both. To investigate the effects of common methods of skin preparation on transdermal drug penetration in vitro, we clipped, harvested, and froze skin samples from 5 Thoroughbred geldings. Thawed samples were prepared as follows: control (no preparation); cleaned with aqueous chlorhexidine (Aq-C, 0.1% w/v); cleaned with alcoholic chlorhexidine (Al-C, 0.5% w/v); shaved (Sh); or tape-stripped (Ta) with the use of adhesive tape. The samples were then placed in diffusion cells, and 2 g of methylsalicylate (MeSa) gel (Dencorub) was applied to the stratum corneum side. The penetration of MeSa and its analyte, salicylate (Sa), through the skin samples was measured over 10 h. Compared with control skin, significantly more MeSa penetrated through skin prepared with Al-C or Sh (P < 0.01) or with Aq-C or Ta (P < 0.05), and significantly more Sa was recovered in the receptor phase from skin prepared with Aq-C, Al-C, or Sh (P < 0.05) or with Ta (P < 0.01). A significantly higher rate of penetration and shorter lag time were also noted for MeSa with all the prepared skin samples, compared with the control samples. The results show that clinical techniques routinely used to clean or prepare skin can significantly affect the rate and extent of penetration of a topically applied drug. This may result in greater systemic availability of active drug, which could lead to enhanced efficacy and, possibly, a higher incidence of adverse effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of three vehicles, phosphate-buffered saline (PBS), ethanol (50% in PBS w/w) and propylene glycol (50% in PBS w/w) on in vitro transdermal penetration of testosterone was investigated in the horse. Skin was harvested from the thorax of five Thoroughbred horses after euthanasia and stored at -20 degrees C until required. The skin was then defrosted and placed into Franz-type diffusion cells, which were maintained at approximately 32 degrees C by a water bath. Saturated solutions of testosterone, containing trace amounts of radiolabelled [C-14]testosterone, in each vehicle were applied to the outer (stratum corneum) surface of each skin sample and aliquots of receptor fluid were collected at 0, 2, 4, 8, 16, 20, 22 and 24 h and analysed for testosterone by scintillation counting. The maximum flux (J(max)) of testosterone was significantly higher for all sites when testosterone was dissolved in a vehicle containing 50% ethanol or 50% propylene glycol, compared to PBS. In contrast, higher residues of testosterone were found remaining within the skin when PBS was used as a vehicle. This study shows that variability in clinical response to testosterone could be expected with formulation design.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Little is known about the transdermal penetration of hydrocortisone in the horse and, although commercial formulations containing hydrocortisone are registered for topical use in the horse, there have been no studies investigating the movement of this glucocorticoid through different regions of equine skin. Skin was harvested from the thorax, groin and leg (dorsal metacarpal) regions of five Thoroughbred geldings and frozen (-20 degrees C) until required. Defrosted skin was placed in Franz-type diffusion cells and the amount of radiolabelled (H-3) hydrocortisone, in a saturated solution of unlabelled hydrocortisone in 50% ethanol (w/w), which penetrated through and remained within skin samples was measured over 24 h. Significantly higher (P < 0.001) maximum flux (J(max); mol/cm(2)/h) was measured when hydrocortisone was applied to skin from the leg, compared to thorax and groin, although significantly less hydrocortisone (P < 0.001) was retained within skin from the leg at 24 h. Topical application of hydrocortisone in a vehicle containing ethanol would penetrate faster through leg skin from the lower leg when compared with the thorax or groin, which depending on cutaneous blood flow, may result in higher systemic drug concentrations or greater efficiency in treating local inflamed tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of the vehicles phosphate-buffered saline (PBS), ethanol (EtOH; 50% in PBS w/w) and propylene glycol (PG; 50% in PBS w/w) and the region of administration on in vitro transdermal penetration of testosterone was investigated in the dog. Skin was harvested from the thorax, neck (dorsal part) and groin regions of greyhounds after euthanasia and stored at -20 degrees C until required. The skin was then de-frosted and placed into Franz-type diffusion cells which were maintained at approximately 32 degrees C by a water-bath. Saturated solutions of testosterone, containing trace amounts of radiolabelled (C-14) testosterone, in each vehicle were applied to the outer (stratum corneum) surface of each skin sample and aliquots of receptor fluid were collected at 0, 2, 4, 8, 16, 20, 22 and 24 h and analysed for testosterone by scintillation counting. The maximum flux (J(max)) of testosterone was significantly higher for all sites when dissolved in a vehicle containing 50% EtOH or 50% PG, compared to PBS. In contrast, higher residues of testosterone were found remaining within the skin when PBS was used as a vehicle. This study shows that variability in percutaneous penetration of testosterone could be expected with formulation design and site of application. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of topical pharmaceutical formulations is increasingly popular in veterinary medicine. A potential concern is that not all formulations are registered for the intended species, yet current knowledge strongly suggests that simple extrapolation of transdermal drug pharmacokinetics and pharmacodynamics between species, including humans, cannot be done. In this review, an overview is provided of the underlying basic principles determining the movement of topically applied molecules into and through the skin. Various factors that may affect transdermal drug penetration between species, between individuals of a particular species and regional differences in an individual are also discussed. A good understanding of the basic principles of transdermal drug delivery is critical to avoid adverse effects or lack of efficacy when applying topical formulations in veterinary medicine. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To systematically review radiofrequency ablation (RFA) for treating liver tumors. Data Sources: Databases were searched in July 2003. Study Selection: Studies comparing RFA with other therapies for hepatocellular carcinoma (HCC) and colorectal liver metastases (CLM) plus selected case series for CLM. Data Extraction: One researcher used standardized data extraction tables developed before the study, and these were checked by a second researcher. Data Synthesis: For HCC, 1.3 comparative studies were included, 4 of which were randomized, controlled trials. For CLM, 13 studies were included, 2 of which were nonrandomized comparative studies and 11 that were case series. There did not seem to be any distinct differences in the complication rates between RFA and any of the other procedures for treatment of HCC. The local recurrence rate at 2 years showed a statistically significant benefit for RFA over percutaneous ethanol injection for treatment of HCC (6% vs 26%, 1 randomized, controlled trial). Local recurrence was reported to be more common after RFA than after laser-induced thermotherapy, and a higher recurrence rate and a shorter time to recurrence were dassociated with RFA compared with surgical resection (1 nonrandomized study each). For CLM, the postoperative complication rate ranged from 0% to 33% (3 case series). Survival after diagnosis was shorter in the CLM group treated with RFA than in the surgical resection group (1 nonrandomized study). The CLM local recurrence rate after RFA ranged from 4% to 55% (6 case series). Conclusions: Radiofrequency ablation may be more effective than other treatments in terms of less recurrence of HCC and may be as sale, although the evidence is scant. There was not enough evidence to determine the safety or efficacy of RFA for treatment of CLM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 52-year-old male with idiopathic hypereosinophilic syndrome (HES) was transferred to our institution following the development of acute respiratory failure and shock. He had previously undergone tricuspid valve replacement with bioprosthetic valves on two occasions: the initial surgery for severe native tricuspid valve stenosis and the redo surgery for severe prosthetic valve stenosis and regurgitation. Conventional imaging assessment using transoesophageal echocardiography was suboptimal and comprehensive assessment of prosthetic valve function was aided by the use of intracardiac echocardiography (ICE). ICE provided high quality 2D imaging of the prosthesis demonstrating thrombus-like material coating the inner surfaces of the prosthetic valve stents effectively forming a tunnel-like obstruction. Unusual hemodynamics secondary to severe tricuspid stenosis were demonstrated by CW Doppler with intermittent signal fusion resulting from blunted respiratory variation in the markedly elevated right atrial pressure relative to right ventricular pressure. Successful balloon valvuloplasty was performed with ICE proving highly valuable in guiding balloon position as well as monitoring the efficacy of the subsequent inflations.