39 resultados para human reliability assessment


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To evaluate the reliability and validity of a brief physical activity assessment tool suitable for doctors to use to identify inactive patients in the primary care setting. Methods: Volunteer family doctors (n = 8) screened consenting patients (n = 75) for physical activity participation using a brief physical activity assessment tool. Inter-rater reliability was assessed within one week (n = 71). Validity was assessed against an objective physical activity monitor (computer science and applications accelerometer; n = 42). Results: The brief physical activity assessment tool produced repeatable estimates of sufficient total physical activity, correctly classifying over 76% of cases (kappa 0.53, 95% confidence interval (CI) 0.33 to 0.72). The validity coefficient was reasonable (kappa 0.40, 95% CI 0.12 to 0.69), with good percentage agreement (71%). Conclusions: The brief physical activity assessment tool is a reliable instrument, with validity similar to that of more detailed self report measures of physical activity. It is a tool that can be used efficiently in routine primary healthcare services to identify insufficiently active patients who may need physical activity advice.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background and Purpose. Arm lymphedema following breast cancer In this study, we assessed the surgery is a continuing problem. reliability and validity of circumferential measurements and water displacement for measuring upper-limb volume. Subjects. Participants included subjects who had had breast cancer surgery, including axillary dissection-19 with and 22 without a diagnosis of arm lymphedema-and 25 control subjects. Methods. Two raters measured each subject by using circumferential tape measurements at specified distances from the fingertips and in relation to anatornic landmarks and by using water displacement. Interrater reliability was calculated by analysis of variance and multilevel modeling. Volumes from circumferential measurements were compared with those from water displacement by use of means and correlation coefficients, respectively. The standard error of measurement, minimum detectable change (MDC), and limits of agreement (LOA) for volumes also were calculated. Results. Arm volumes obtained with these methods had high reliability. Compared with volumes from water displacement, volumes from circumferential measurements had high validity, although these volumes were slightly larger. Expected differences between subjects with and without clinical lymphedema following breast cancer were found. The MDC of volumes or the error associated with a single measure for data based oil anatomic landmarks was lower than that based oil distance from fingertips. The mean LOA with water displacement were lower for data based on anatomic landmarks than for data based on distance from fingertips. Discussion and Conclusion. Volumes calculated from anatomic landmarks are reliable, valid, and more accurate than those obtained from circumferential measurements based on distance from fingertips.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study determined the inter-tester and intra-tester reliability of physiotherapists measuring functional motor ability of traumatic brain injury clients using the Clinical Outcomes Variable Scale (COVS). To test inter-tester reliability, 14 physiotherapists scored the ability of 16 videotaped patients to execute the items that comprise the COVS. Intra-tester reliability was determined by four physiotherapists repeating their assessments after one week, and three months later. The intra-class correlation coefficients (ICC) were very high for both inter-tester reliability (ICC > 0.97 for total COVS scores, ICC > 0.93 for individual COVS items) and intra-tester reliability (ICC > 0.97). This study demonstrates that physiotherapists are reliable in the administration of the COVS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To determine the relationship between pediatric assessment scores and ratings by parents and teachers regarding the amount of assistance required to complete basic activities of daily living; and to examine the relationship among scores for three commonly used pediatric assessments. Design: Prospective correlational study. 205 children with developmental disabilities. The children ranged in age from 11 to 87 mo and included 72 females and 133 males of diverse socioeconomic and ethnic backgrounds. The children were evaluated by using the Battelle Developmental Inventory Screening Test, Vineland Adaptive Behavior Scales, Functional Independence Measure for Children (WeeFIM(TM) instrument), and the Amount of Assistance Questionnaire, Results: The test-retest reliability coefficients for items on the Amount of Assistance Questionnaire were found to range from 0.82 to 0.97. Correlations among subscale scores and amount of assistance ratings were highest for the WeeFIM instrument and Battelle Developmental Inventory Screening Test. The highest correlation was between WeeFIM total rating and total amount of assistance rating (r = 0.91). Conclusion: Total WeeFIM instrument ratings and severity of disability were the best predictors of amount of assistance ratings provided by parents and teachers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Self-regulation Skills Interview (SRSI) is a clinical tool designed to measure a range of metacognitive skills essential for rehabilitation planning, monitoring an individual's progress, and evaluating the outcome of treatment interventions. The results of the present study indicated that the SRSI has sound interrater reliability and test-retest reliability. A principle components analysis revealed three SRSI factors: Awareness, Readiness to Change, and Strategy Behavior. A comparison between a group of 61 participants with acquired brain injury (ABI) and a group of 43 non-brain-injured participants indicated that the participants with ABI had significantly lower levels of Awareness and Strategy Behavior, but that level of Readiness to Change was not significantly different between the two groups. The significant relationship observed between the SRSI factors and measures of neuropsychological functioning confirmed the concurrent validity of the scale and supports the value of the SRSI for post-acute assessment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is a need for improved monitoring and evaluation (M&E) of participatory research with smallholder farmers, in particular to help differentiate between different types of farm household with different needs. This paper reports some of the results of a study to develop participatory M&E tools for the Forages for Smallholders Project in Southeast Asia, focusing on an upland commune in central Vietnam with a highly diverse crop-livestock system. Participatory rural appraisal techniques were used within a rural livelihoods framework to assess the differing livelihoods of poor, average, and better-off households. There were found to be marked differences between households, particularly in human resources, landholdings, and cattle numbers, affecting the livelihood strategies pursued. The improved understanding of livelihood strategies was gained in a cost-effective way and could be readily used by project participants to monitor the impacts of the introduced forages within the commune, enabling better focusing of the participatory research process on the needs and circumstances of poor farmers. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The technical reliability (i.e., interinstrument and interoperator reliability) of three SEAC-swept frequency bioimpedance monitors was assessed for both errors of measurement and associated analyses. In addition, intraoperator and intrainstrument variability was evaluated for repeat measures over a 4-hour period. The measured impedance values from a range of resistance-capacitance circuits were accurate to within 3% of theoretical values over a range of 50-800 ohms. Similarly, phase was measured over the range 1 degrees-19 degrees with a maximum deviation of 1.3 degrees from the theoretical value. The extrapolated impedance at zero frequency was equally well determined (+/-3%). However, the accuracy of the extrapolated value at infinite frequency was decreased, particularly at impedances below 50 ohms (approaching the lower limit of the measurement range of the instrument). The interinstrument/operator variation for whole body measurements were recorded on human volunteers with biases of less than +/-1% for measured impedance values and less than 3% for phase. The variation in the extrapolated values of impedance at zero and infinite frequencies included variations due to operator choice of the analysis parameters but was still less than +/-0.5%. (C) 1997 Wiley-Liss, Inc.