106 resultados para harmonic distortion
Resumo:
We compare the performance of two different low-storage filter diagonalisation (LSFD) strategies in the calculation of complex resonance energies of the HO2, radical. The first is carried out within a complex-symmetric Lanczos subspace representation [H. Zhang, S.C. Smith, Phys. Chem. Chem. Phys. 3 (2001) 2281]. The second involves harmonic inversion of a real autocorrelation function obtained via a damped Chebychev recursion [V.A. Mandelshtam, H.S. Taylor, J. Chem. Phys. 107 (1997) 6756]. We find that while the Chebychev approach has the advantage of utilizing real algebra in the time-consuming process of generating the vector recursion, the Lanczos, method (using complex vectors) requires fewer iterations, especially for low-energy part of the spectrum. The overall efficiency in calculating resonances for these two methods is comparable for this challenging system. (C) 2001 Elsevier Science B.V. All rights reserved.
Cavity QED analog of the harmonic-oscillator probability distribution function and quantum collapses
Resumo:
We establish a connection between the simple harmonic oscillator and a two-level atom interacting with resonant, quantized cavity and strong driving fields, which suggests an experiment to measure the harmonic-oscillator's probability distribution function. To achieve this, we calculate the Autler-Townes spectrum by coupling the system to a third level. We find that there are two different regions of the atomic dynamics depending on the ratio of the: Rabi frequency Omega (c) of the cavity field to that of the Rabi frequency Omega of the driving field. For Omega (c)
Resumo:
We show that stochastic electrodynamics and quantum mechanics give quantitatively different predictions for the quantum nondemolition (QND) correlations in travelling wave second harmonic generation. Using phase space methods and stochastic integration, we calculate correlations in both the positive-P and truncated Wigner representations, the latter being equivalent to the semi-classical theory of stochastic electrodynamics. We show that the semiclassical results are different in the regions where the system performs best in relation to the QND criteria, and that they significantly overestimate the performance in these regions. (C) 2001 Published by Elsevier Science B.V.
Resumo:
Symptoms of bladder irritability are common after incontinence surgery but their cause is unknown. This study tests the hypothesis that irritative symptoms after colposuspension are due to distortion of the trigone. As part of longitudinal follow-up studies, 175 women were examined 6 months to 12 years after either an open or a laparoscopic Burch colposuspension. The main outcome measures were symptoms of bladder irritability (frequency, nocturia and urge incontinence) and ultrasound findings (bladder neck position at rest and on Valsalva, the presence of a colposuspension ridge, ridge depth and ridge distance, and trigonal angle). Two positive associations between ultrasound parameters and symptoms of bladder irritability were observed: urge incontinence was more likely in the presence of bladder neck funneling, and women with nocturia had a higher trigonal angle. Increased distortion of the trigone was associated with a reduced incidence of urge incontinence in the subgroup of patients after laparoscopic colposuspension. The data presented in this study do not support the hypothesis that symptoms of bladder irritability are due to trigonal distortion or overelevation.
Resumo:
Ellipsoidal harmonics are presented as a basis function set for the design of shim coils for magnetic resonance imaging (MRI) or spectroscopy. MR shim coils may be either superconductive or resistive. Ellipsoidal harmonics form an orthogonal set over an ellipsoid and hence are appropriate in circumstances where the imaging or spectroscopic region of a magnet more closely conforms to an ellipsoid rather than a sphere. This is often the case in practice. The Cartesian form of ellipsoidal harmonics is discussed. A method for the design of streamline coil designs is detailed and patterns for third-order ellipsoidal (Lame) shims wound on a cylindrical surface are presented.
Resumo:
Evoked otoacoustic emissions have demonstrated potential for application in the community-based hearing screening of paediatric populations. Distortion-product otoacoustic emissions (DPOAEs), as opposed to transient evoked otoacoustic emissions (TEOAEs), have not been extensively researched in this regard. The current study aimed to describe the range of DPOAE values obtained in a large cohort (1576 ears) of 6-year-old children in school settings and to examine possible ear asymmetry, gender and history of ear infection effects on the data. Results indicated a variety of significant effects, particularly in the high frequencies, for DPOAE signal-to-noise ratio. The measurement parameter, DPOAE amplitude (DP-amp), was found to display potentially less clinical applicability due to large standard deviation values. Use of descriptive normative data, as derived in the present investigation, may contribute toward future improvements in the hearing screening of 6-year-old schoolchildren
Resumo:
When asked to compare two lateralized shapes for horizontal size, neglect patients often indicate the left stimulus to be smaller. Gainotti and Tiacci (1971) hypothesized that this phenomenon might be related to a rightward bias in the patients' gaze. This study aimed to assess the relation between this size underestimation and oculomotor asymmetries. Eye movements were recorded while three neglect patients judged the horizontal extent of two rectangles. Two experimental manipulations were performed to increase the likelihood of symmetrical scanning of the stimulus display. The first manipulation entailed a sequential, rather than simultaneous presentation of the two rectangles. The second required adaptation to rightward displacing prisms, which is known to reduce many manifestations of neglect. All patients consistently underestimated the left rectangle, but the pattern of verbal responses and eye movements suggested different underlying causes. These include a distortion of space perception without ocular asymmetry, a failure to view the full leftward extent of the left stimulus, and a high-level response bias. Sequential presentation of the rectangles and prism adaptation reduced ocular asymmetries without affecting size underestimation. Overall, the results suggest that leftward size underestimation in neglect can arise for a number of different reasons. Incomplete leftward scanning may perhaps be sufficient to induce perceptual size distortion, but it is not a necessary prerequisite.
Resumo:
A phantom that can be used for mapping geometric distortion in magnetic resonance imaging (MRI) is described. This phantom provides an array of densely distributed control points in three-dimensional (3D) space. These points form the basis of a comprehensive measurement method to correct for geometric distortion in MR images arising principally from gradient field non-linearity and magnet field inhomogeneity. The phantom was designed based on the concept that a point in space can be defined using three orthogonal planes. This novel design approach allows for as many control points as desired. Employing this novel design, a highly accurate method has been developed that enables the positions of the control points to be measured to sub-voxel accuracy. The phantom described in this paper was constructed to fit into a body coil of a MRI scanner, (external dimensions of the phantom were: 310 mm x 310 mm x 310 mm), and it contained 10,830 control points. With this phantom, the mean errors in the measured coordinates of the control points were on the order of 0.1 mm or less, which were less than one tenth of the voxel's dimensions of the phantom image. The calculated three-dimensional distortion map, i.e., the differences between the image positions and true positions of the control points, can then be used to compensate for geometric distortion for a full image restoration. It is anticipated that this novel method will have an impact on the applicability of MRI in both clinical and research settings. especially in areas where geometric accuracy is highly required, such as in MR neuro-imaging. (C) 2004 Elsevier Inc. All rights reserved.
Resumo:
Recently, a 3-dimensional phantom that can provide a comprehensive, accurate and complete measurement of the geometric distortion in MRI has been developed. In this paper, a scheme for characterizing the measured geometric distortion using the 3-D phantom is described. In the proposed scheme, a number of quantitative measures are developed and used to characterize the geometric distortion. These measures encompass the overall and spatial aspects of the geometric distortion. Two specific types of volume of interest, rectangular parallelepipeds (including cubes) and spheres are considered in the proposed scheme. As an illustration, characterization of the geometric distortion in a Siemens 1.5T Sonata MRI system using the proposed scheme is presented. As shown, the proposed scheme provides a comprehensive assessment of the geometric distortion. The scheme can be potentially used as a standard procedure for the assessment of geometric distortion in MRI. (C) 2004 American Association of Physicists in Medicine.
Resumo:
In this paper, we present the correction of the geometric distortion measured in the clinical magnetic resonance imaging (MRI) systems reported in the preceding paper (Part 1) using a 3D method based on the phantom-mapped geometric distortion data. This method allows the correction to be made on phantom images acquired without or with the vendor correction applied. With the vendor's 2D correction applied, the method corrects for both the residual geometric distortion still present in the plane in which the correction method was applied (the axial plane) and the uncorrected geometric distortion along the axis non-nal to the plane. The evaluation of the effectiveness of the correction using this new method was carried out through analyzing the residual geometric distortion in the corrected phantom images. The results show that the new method can restore the distorted images in 3D nearly to perfection. For all the MRI systems investigated, the mean absolute deviations in the positions of the control points (along x-, y- and z-axes) measured on the corrected phantom images were all less than 0.2 mm. The maximum absolute deviations were all below similar to0.8 mm. As expected, the correction of the phantom images acquired with the vendor's correction applied in the axial plane performed equally well. Both the geometric distortion still present in the axial plane after applying the vendor's correction and the uncorrected distortion along the z-axis have all been restored. (C) 2004 Elsevier Inc. All rights reserved.
Resumo:
Recently, a 3D phantom that can provide a comprehensive and accurate measurement of the geometric distortion in MRI has been developed. Using this phantom, a full assessment of the geometric distortion in a number of clinical MRI systems (GE and Siemens) has been carried out and detailed results are presented in this paper. As expected, the main source of geometric distortion in modern superconducting MRI systems arises from the gradient field nonlinearity. Significantly large distortions with maximum absolute geometric errors ranged between 10 and 25 mm within a volume of 240 x 240 x 240 mm(3) were observed when imaging with the new generation of gradient systems that employs shorter coils. By comparison, the geometric distortion was much less in the older-generation gradient systems. With the vendor's correction method, the geometric distortion measured was significantly reduced but only within the plane in which these 2D correction methods were applied. Distortion along the axis normal to the plane was, as expected, virtually unchanged. Two-dimensional correction methods are a convenient approach and in principle they are the only methods that can be applied to correct geometric distortion in a single slice or in multiple noncontiguous slices. However, these methods only provide an incomplete solution to the problem and their value can be significantly reduced if the distortion along the normal of the correction plane is not small. (C) 2004 Elsevier Inc. All rights reserved.
Resumo:
Otoacoustic emissions are frequently acquired from patients in a variety of body positions aside from the standard, seated orientation. Yet little knowledge is available regarding whether these deviations will produce nonpathological changes to the clinical results obtained. The present study aimed to describe the effects of body position on the distortion-product otoacoustic emissions of 60 normal-hearing adults. With particular attention given to common clinical practice, the Otodynamics ILO292, and the measurement parameters of amplitude, signal-to-noise ratio, and noise were utilized. Significant position-related effects and interactions were revealed for all parameters. Specifically, stronger emissions in the mid frequencies and higher noise levels at the extreme low and high frequencies were produced by testing subjects while lying on their side compared with the seated position. Further analysis of body position effects on emissions is warranted, in order to determine the need for clinical application of position-dependent normative data.
Resumo:
Genetic segregation experiments with plant species are commonly used for understanding the inheritance of traits. A basic assumption in these experiments is that each gamete developed from megasporogenesis has an equal chance of fusing with a gamete developed from microsporogenesis, and every zygote formed has an equal chance of survival. If gametic and/or zygotic selection occurs whereby certain gametes or zygotic combinations have a reduced chance of survival, progeny distributions are skewed and are said to exhibit segregation distortion. In this study, inheritance data are presented for the trait seed testa color segregating in large populations (more than 200 individuals) derived from closely related mungbean (Vigna radiata L. Wilcek) taxa. Segregation ratios suggested complex inheritance, including dominant and recessive epistasis. However, this genetic model was rejected in favor of a single-gene model based on evidence of segregation distortion provided by molecular marker data. The segregation distortion occurred after each generation of self-pollination from F-1 thru F-7 resulting in F-7 phenotypic frequencies of 151:56 instead of the expected 103.5:103.5. This study highlights the value of molecular markers for understanding the inheritance of a simply inherited trait influenced by segregation distortion.
Resumo:
The Einstein-Podolsky-Rosen paradox and quantum entanglement are at the heart of quantum mechanics. Here we show that single-pass traveling-wave second-harmonic generation can be used to demonstrate both entanglement and the paradox with continuous variables that are analogous to the position and momentum of the original proposal.