54 resultados para half-frequency bunching
Resumo:
The free running linewidth of an external cavity grating feedback diode laser is on the order of a few megahertz and is limited by the mechanical and acoustic vibrations of the external cavity. Such frequency fluctuations can be removed by electronic feedback. We present a hybrid stabilisation technique that uses both a Fabry-Perot confocal cavity and an atomic resonance to achieve excellent short and long term frequency stability. The system has been shown to reduce the laser linewidth of an external cavity diode laser by an order of magnitude to 140 kHz, while limiting frequency excursions to 60 kHz relative to an absolute reference over periods of several hours. The scheme also presents a simple way to frequency offset two lasers many gigahertz apart which should find a use in atom cooling experiments, where hyperfine ground-state frequency separations are often required.
Resumo:
Curing of diglycidyl ether of bisphenol A/diaminodiphenyl sulfone (DGEBA/DDS) epoxy resin has been effected by heating with radio frequency (RF) radiation at frequencies of 30-99 MHz. The epoxy resins can be cured rapidly at low RF power levels. Comparison of the kinetics of the RF curing with thermal curing while maintaining the same curing temperature revealed no differences. Previous differences in rates of thermal and microwave curing are believed to be due to lack of temperature control during microwave curing. For RF curing,the rate of cure, at constant power level, increases at lower RF frequency, thus emphasizing one of the principal advantages of RF curing over microwave curing. (C) 1999 John Wiley & Sons, Inc.
Resumo:
Objective-To test the hypothesis that proposed amendments to the Occupational Safety and Health Act making all enclosed workplaces in Western Australia smoke free would result in a decrease in cigarette consumption by patrons at nightclubs, pubs, and restaurants without adversely affecting attendance. Design-Cross sectional structured interview survey. Participants and setting-Patrons of several inner city pubs and nightclubs in Perth were interviewed while queuing for admission to these venues. Outcome measures-Current social habits, smoking habits, and how these might be affected by the proposed regulations. Persons who did not smoke daily were classified as social smokers. Results-Half (50%) of the 374 patrons interviewed were male, 51% currently did not smoke at all, 34.3% smoked every day, and the remaining 15.7% smoked, brat not every day. A clear majority (62.5%) of all 374 respondents anticipated no change to the frequency of their patronage of hospitality venues if smoke-free policies became mandatory One in five (19.3%) indicated that they would,ao out more often, and 18.2% said they would go out less often. Half (52%) of daily smokers anticipated no change to their cigarette consumption, while 44.5% of daily smokers anticipated a reduction in consumption. A majority of social smokers (54%) predicted a reduction in their cigarette consumption, with 42% of these anticipating quitting. Conclusions-One in nine (11.5%) of smokers say that adoption of smoke-Pi ee policies would prompt them to quit smoking entirely without a significant decrease in attendance at pubs and nightclubs. There can be few other initiatives as simple, cheap, and popular that would achieve so much for public health.
Resumo:
Bioelectrical impedance analysis has found extensive application as a simple noninvasive method for the assessment of body fluid volumes, The measured impedance is, however, not only related to the volume of fluid but also to its inherent resistivity. The primary determinant of the resistivities of body fluids is the concentration of ions. The aim of this study was to investigate the sensitivity of bioelectrical impedance analysis to bodily ion status. Whole body impedance over a range of frequencies (4-1012 kHz) of rats was measured during infusion of various concentrations of saline into rats concomitant with measurement of total body and intracellular water by tracer dilution techniques. Extracellular resistance (R-o), intracellular resistance (R-i) and impedance at the characteristic frequency (Z(c)) were calculated. R-o and Z(c) were used to predict extracellular and total body water respectively using previously published formulae. The results showed that whilst R-o and Z(c) decreased proportionately to the amount of NaCl infused, R-i increased only slightly. Impedances at the end of infusion predicted increases iu TBW and ECW of approximately 4-6% despite a volume increase of less than 0.5% in TBW due to the volume of fluid infused. These data are discussed in relation to the assumption of constant resistivity in the prediction of fluid volumes from impedance data.
Resumo:
We propose a single optical photon source for quantum cryptography based on the acoustoelectric effect. Surface acoustic waves (SAWs) propagating through a quasi-one-dimensional channel have been shown to produce packets of electrons that reside in the SAW minima and travel at the velocity of sound. In our scheme, the electron packets are injected into a p-type region, resulting in photon emission. Since the number of electrons in each packet can be controlled down to a single electron, a stream of single- (or N-) photon states, with a creation time strongly correlated with the driving acoustic field, should be generated.
Resumo:
It has recently been stated that the parametrization of the time variables in the one-dimensional (I-D) mixing-frequency electron spin-echo envelope modulation (MIF-ESEEM) experiment is incorrect and hence the wrong frequencies for correlated nuclear transitions are predicted. This paper is a direct response to such a claim, its purpose being to show that the parametrization in land 2-D MIF-ESEEM experiments possesses the same form as that used in other 4-pulse incrementation schemes and predicts the same correlation frequencies. We show that the parametrization represents a shearing transformation of the 2-D time-domain and relate the resulting frequency domain spectrum to the HYSCORE spectrum in terms of a skew-projection. It is emphasized that the parametrization of the time-domain variables may be chosen arbitrarily and affects neither the computation of the correct nuclear frequencies nor the resulting resolution. The usefulness or otherwise of the MIF parameters \gamma\ > 1 is addressed, together with the validity of the original claims of the authors with respect to resolution enhancement in cases of purely homogeneous and inhomogeneous broadening. Numerical simulations are provided to illustrate the main points.
Resumo:
Background and Purpose-Limited information exists on the long-term prognosis after first-ever stroke. We aimed to determine the absolute frequency of first recurrent stroke and disability and the relative frequency of recurrent stroke over 10 years after first-ever stroke in Perth, Western Australia. Methods-For a 12-month period beginning February 1989, all individuals with suspected acute stroke or transient ischemic attack who lived in a geographically defined and representative region of Perth were registered prospectively. Patients with a definite first-ever stroke were followed up 10 years after the index event. Results-Over 10 years of follow-up, the cumulative risk of a first recurrent stroke was 43% (95% confidence interval [CI], 34 to 51). After the first year after first-ever stroke, the average annual risk of recurrent stroke was approximate to4%. Case fatality at 30 days after first recurrent stroke was 41%, which was significantly greater than the case fatality at 30 days after first-ever stroke (22%) (P=0.003). For 30-day survivors of first-ever stroke, the 10-year cumulative risk of death or new institutionalization was 79% (95% CI, 73 to 85) and of death or new disability was 87% (95% CI, 81 to 92). Conclusions-Over 10 years of follow-up, the risk of first recurrent stroke is 6 times greater than the risk of first-ever stroke in the general population of the same age and sex, almost one half of survivors remain disabled, and one seventh require institutional care. Effective strategies for prevention of stroke need to be implemented early, monitored frequently, and maintained long term after first-ever stroke.
Resumo:
We present a new sample of Parkes half-jansky flat-spectrum radio sources, having made a particular effort to find any previously unidentified sources. The sample contains 323 sources selected according to a flux limit of 0.5 Jy at 2.7 GHz, a spectral index measured between 2.7 and 5.0 GHz of alpha(2.7/5.0) > -0.5, where S(nu) proportional to nu(alpha), Galactic latitude \b\ > 20 degrees and -45 degrees < declination (B1950) < +10 degrees. The sample was selected from a region 3.90 steradians in area. We have obtained accurate radio positions for all the unresolved sources in this sample, and combined these with accurate optical positions from digitized photographic sky survey data to check all the optical identifications. We report new identifications based on R- and Kn-band imaging and new spectroscopic measurements of many of the sources. We present a catalogue of the 323 sources, of which 321 now have identified optical counterparts and 277 have measured spectral redshifts.
Resumo:
The technical reliability (i.e., interinstrument and interoperator reliability) of three SEAC-swept frequency bioimpedance monitors was assessed for both errors of measurement and associated analyses. In addition, intraoperator and intrainstrument variability was evaluated for repeat measures over a 4-hour period. The measured impedance values from a range of resistance-capacitance circuits were accurate to within 3% of theoretical values over a range of 50-800 ohms. Similarly, phase was measured over the range 1 degrees-19 degrees with a maximum deviation of 1.3 degrees from the theoretical value. The extrapolated impedance at zero frequency was equally well determined (+/-3%). However, the accuracy of the extrapolated value at infinite frequency was decreased, particularly at impedances below 50 ohms (approaching the lower limit of the measurement range of the instrument). The interinstrument/operator variation for whole body measurements were recorded on human volunteers with biases of less than +/-1% for measured impedance values and less than 3% for phase. The variation in the extrapolated values of impedance at zero and infinite frequencies included variations due to operator choice of the analysis parameters but was still less than +/-0.5%. (C) 1997 Wiley-Liss, Inc.
Resumo:
The technique of frequency-resolved optical gating is used to characterize the intensity and the phase of picosecond pulses after propagation through 700 m of fiber at close to the zero-dispersion wavelength. Using the frequency-resolved optical gating technique, we directly measure the severe temporal distortion resulting from the interplay between self-phase modulation and higher-order dispersion in this regime. The measured intensity and phase of the pulses after propagation are found to be in good agreement with the predictions of numerical simulations with the nonlinear Schrodinger equation. (C) 1997 Optical Society of America.