20 resultados para gaseous


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In wastewater treatment plants with anaerobic sludge digestion, 15-20% of the nitrogen load is recirculated to the main stream with the return liquors from dewatering. Separate treatment of this ammonium-rich digester supernatant significantly reduces the nitrogen load of the activated sludge system. Two biological applications are considered for nitrogen elimination: (i) classical autotrophic nitrification/heterotrophic denitrification and (ii) partial nitritation/autotrophic anaerobic ammonium oxidation (anammox). With both applications 85-90% nitrogen removal can be achieved, but there are considerable differences in terms of sustainability and costs. The final gaseous products for heterotrophic denitrification are generally not measured and are assumed to be nitrogen gas (N-2). However, significant nitrous oxide (N2O) production can occur at elevated nitrite concentrations in the reactor. Denitrification via nitrite instead of nitrate has been promoted in recent years in order to reduce the oxygen and the organic carbon requirements. Obviously this achievement turns out to be rather disadvantageous from an overall environmental point of view. On the other hand no unfavorable intermediates are emitted during anaerobic ammonium oxidation. A cost estimate for both applications demonstrates that partial nitritation/anammox is also more economical than classical nitrification/denitrification. Therefore autotrophic nitrogen elimination should be used in future to treat ammonium-rich sludge liquors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mathematical modelling underlying passive air sampling theory can be based on mass transfer coefficients or rate constants. Generally, these models have not been inter-related. Starting with basic models, the exchange of chemicals between the gaseous phase and the sampler is developed using mass transfer coefficients and rate constants. Importantly, the inter-relationships between the approaches are demonstrated by relating uptake rate constants and loss rate constants to mass transfer coefficients when either sampler-side or air-side resistance is dominating chemical exchange. The influence of sampler area and sampler volume on chemical exchange is discussed in general terms and as they relate to frequently used parameters such as sampling rates and time to equilibrium. Where air-side or sampler-side resistance dominates, an increase in the surface area of the sampler will increase sampling rates. Sampling rates are not related to the sampler/air partition coefficient (K-SV) when air-side resistance dominates and increase with K-SV when sampler-side resistance dominates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seven captive male African wild dogs (Lycaon pictus) weighing 25-32 kg each, were anesthetized by i.m. injection via hand syringe with a combination of 1.5 mg/kg ketamine, 40 mu g/kg medetomidine, and 0.05 mg/kg atropine. Following endotracheal intubation, each animal was connected to a bain closed-circuit system that delivered 1.5% isoflurane and 2 L/min oxygen. Atipamezole (0.1 mg/kg i.v.; 0.1 mg/kg i.m.) was given at the end of each procedure (60 min following injection of medetomidine/ketamine/atropine). Time to sternal recumbency was 5-8 min. Times to standing after atipamezole administration were 8-20 min. This anesthetic regimen was repeated on three separate occasions (September 2000, February 2002, and October 2002) on all males to perform electroejaculation procedures. Each procedure was < 80 min from injection to standing. Dogs showed excellent muscle relaxation during the procedures. Arterial blood samples were collected at 10-min intervals for blood gases in one procedure (September 2000). Separate venous samples were taken from each dog during each procedure for hematology and biochemistry. These values were within the normal range for this species. Arterial hemoglobin oxygen saturation (SpO2) and heart rate (HR) were monitored continuously in addition to other anesthesia monitoring procedures (body temperature, respiratory rate [RR], capillary refill time, blink response, pupil position, deep pain perception reflex). All dogs maintained relatively stable SpO2 profiles during monitoring, with a mean (+/- SD) SpO2 of 92% +/- 5.4%. All other physiological variables (HR, RR, body temperature, blood pressure) were within normal limits. Following each procedure, normal behavior was noted in all dogs. All the dogs were reunited into the pack at completion of their anesthetic procedures. An injectable medetomidine-ketamine-atropine combination with maintenance by gaseous isoflurane and oxygen provides an inexpensive, reliable anesthetic for captive African wild dogs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Error condition detected Although coal may be viewed as a dirty fuel due to its high greenhouse emissions when combusted, a strong case can be made for coal to be a major world source of clean H-2 energy. Apart from the fact that resources of coal will outlast oil and natural gas by centuries, there is a shift towards developing environmentally benign coal technologies, which can lead to high energy conversion efficiencies and low air pollution emissions as compared to conventional coal fired power generation plant. There are currently several world research and industrial development projects in the areas of Integrated Gasification Combined Cycles (IGCC) and Integrated Gasification Fuel Cell (IGFC) systems. In such systems, there is a need to integrate complex unit operations including gasifiers, gas separation and cleaning units, water gas shift reactors, turbines, heat exchangers, steam generators and fuel cells. IGFC systems tested in the USA, Europe and Japan employing gasifiers (Texaco, Lurgi and Eagle) and fuel cells have resulted in energy conversions at efficiency of 47.5% (HHV) which is much higher than the 30-35% efficiency of conventional coal fired power generation. Solid oxide fuel cells (SOFC) and molten carbonate fuel cells (MCFC) are the front runners in energy production from coal gases. These fuel cells can operate at high temperatures and are robust to gas poisoning impurities. IGCC and IGFC technologies are expensive and currently economically uncompetitive as compared to established and mature power generation technology. However, further efficiency and technology improvements coupled with world pressures on limitation of greenhouse gases and other gaseous pollutants could make IGCC/IGFC technically and economically viable for hydrogen production and utilisation in clean and environmentally benign energy systems. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim of study: As part of a Cochrane review of viscosupplementation in knee OA, randomised controlled trials (RCT) were reviewed to evaluate evidence for the efficacy of viscosupplementation with Hylan G-F 20 compared to placebo. Methods: Electronic searches were conducted of MEDLINE, EMBASE, Premedline, Current Contents, and CENTRAL. Human, RCT involving Hylan G-F 20 compared to placebo, published prior to 1Q2004, were included. Trials were selected and data extracted by two independent reviewers. Methodological quality was assessed with the Jadad criteria by two reviewers. Data on the OARSI and OMERACT core set clinical outcome measures were extracted where possible. Weighted mean difference (WMD), based on post-test scores, and 95% confidence intervals (CI) were calculated for continuous outcome measures and relative risk (RR) for dichotomous outcome measures. Results: Seven RCT met the inclusion criteria. Median methodological quality was 4 (range 1–5). A further two studies were only reported in abstract form (Jadad score Z 1) and contained insufficient extractable data for inclusion in the analysis. Nine RCT, which compared Hylan G-F 20 to other interventions such as intra-articular corticosteroid, physiotherapy, NSAID, appropriate care, intra-articular gaseous oxygen and other hyaluronan, are not reported here. Twenty-three studies failed to meet inclusion criteria and were excluded. Hylan G-F 20 was more efficacious than placebo at 1–4 weeks post-injection for pain on weight-bearing WMD (random effects [RE]) 13 mm on a 0–100 mm VAS (P Z 0.002) based on 6 RCT. This difference was even greater at 5–13 weeks post-injection, 22 m (RE) (P Z 0.001) based on 5 RCT, and at 14–6 weeks postinjection, 21 m (RE) (P Z 0.006) based on 4 RCT. Hylan G-F 20 was more efficacious than placebo at 1–4 weeks post-injection for pain at night, WMD 7 mm on a 0–100 mm VAS (P Z 0.003) based on 5 RCT. This difference was even greater at 5–13 weeks post-injection, 11 mm (P Z 0.008) based on 4 RCT, and at 14–26 weeks post-injection, 17 mm (P ! 0.00001) based on 3 RCT. There was no significant difference (WMD 8 mm) between Hylan G-F 20 C oral placebo and arthrocentesis C oral placebo at 5–13 weeks post-injection for WOMAC Pain, but Hylan G-F 20 C oral placebo was more efficacious than arthrocentesis C oral placebo for WOMAC Function, WMD 9 mm on a 0–100 mm VAS (P Z 0.01) (Dickson, 2001). Hylan G-F 20 was more effective than placebo at 1–4 weeks postinjection for the variable designed treatment efficacy, WMD 22 mm on a 0–100 mm VAS (P ! 0.00001) based on improvement in 4 RCT. This difference was even greater at 5–13 weeks post injection, 35 mm (P ! 0.00001). Conclusions: Evidence from this updated Cochrane review supports the superior efficacy of Hylan G-F 20 compared to placebo on weight-bearing pain, night pain, function and treatment efficacy in the treatment of knee OA.