23 resultados para Ultrasonic velocity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of cervical manipulation presents concerns because of a risk of devastating side effects of trauma to the vertebral artery. Little is known about the frequency of use of cervical manipulation versus passive mobilisation by physiotherapists. A recent national, multi-centre randomised clinical trial of the physiotherapy management of cervicogenic headache provided an opportunity to gain an insight into practices of a sample of manipulative physiotherapists across Australia. The treatment records for the 100 subjects who received only manipulative therapy, or manipulative therapy with exercise as per the trial protocol, were audited. The results revealed that cervical manipulation was used in 20.2% of the 1090 treatments provided to these subjects but cervical joint mobilisation only was used in the vast majority of treatments (77.6%). Nevertheless, 42% of subjects were treated with cervical manipulation at some time. In most instances, manipulation was accompanied by passive mobilisation in the same treatment session. Patients were manipulated on one to six occasions and this occurred predominantly in the latter half of the 12-treatment program. Cervical manipulation was used less frequently in the group who also received exercise. The data suggest that the physiotherapists participating in this study used cervical manipulation selectively and relatively conservatively considering the high use of cervical mobilisation techniques. This may reflect their due regard to safety in the treatment of the cervical region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Systolic myocardial Doppler velocity accurately identifies coronary artery disease. However, these velocities may be affected by age, hemodynamic responses to stress, and left ventricular cavity size. We sought to examine the influences of these variables on myocardial velocity during dobutamine stress in patients with normal wall motion. Methods One hundred seventy-nine consecutive patients with normal dobutamine echocardiograms were studied. Color myocardial tissue Doppler data were obtained at rest and peak stress, and peak systolic myocardial velocity (PSV) was measured in all basal and midventricular segments. Velocities at rest and peak stress were compared with left ventricular diastolic and systolic volumes, blood pressure, heart rate, and age by Pearson correlation and interdecile analysis by use of analysis of variance. Results The only clinical variable correlating with velocity was age; PSV showed only mild correlation with age at rest (r(2) = 0.01, P = .001) and peak stress (r(2) = 0.02, P = .001), but the normal peak velocity was significantly different between the extremes of age (<44 years and >74 years). There was very weak correlation of PSV with systolic and diastolic blood pressure (r(2) < 0.01), heart rate (r(2) < 0.01), systemic vascular resistance (r(2) = 0.08), and left ventricular volumes (r(2) < 0.01). Conclusions Peak systolic velocity during dobutamine stress is relatively independent of hemodynamic factors and left ventricular cavity size. The extremes of age may influence peak systolic Doppler velocities. These results suggest that peak systolic velocity may be a robust quantitative measure during dobutamine echocardiography across most patient subgroups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range investigated. The ultrasonic attenuation dose sensitivity at 4 MHz in MAGIC gels was determined to be 4.7 +/- 0.3 dB m(-1) Gy(-1) and for PAG 3.9 +/- 0.3 dB m(-1) Gy(-1). Ultrasonic speed dose sensitivities were 0.178 +/- 0.006 m s(-1) Gy(-1) for MAGIC gel and -0.44 +/- 0.02 m s(-1) Gy(-1) for PAG. Density and compressional elastic modulus were investigated to explain the different sensitivities of ultrasonic speed to radiation for PAG and MAGIC gels. The different sensitivities were found to be due to differences in the compressional elastic modulus as a function of dose for the two formulations. To understand the physical phenomena underlying the increase in ultrasonic attenuation with dose, the viscoelastic properties of the gels were studied. Results suggest that at ultrasonic frequencies, attenuation in polymer gel dosimeters is primarily due to volume viscosity. It is concluded that ultrasonic attenuation significantly increases with absorbed dose. Also, the ultrasonic speed in polymer gel dosimeters is affected by changes in dosimeter elastic modulus that are likely to be a result of polymerization. It is suggested that ultrasound is a sufficiently sensitive technique for polymer gel dosimetry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A retrospective review of ultrasound guided breast excisional biopsies performed in a Surgical Unit of Princess Alexandra Hospital in 1998-99 was undertaken to assess the use of ultrasound specimen radiography. In this series a total of 55 localization biopsies were performed for impalpable lesions in 53 women. In 21 patients (38%), specimen ultrasound was used to confirm that the lesion in question had been excised, whereas for 34 lesions (62%), specimen X-ray was undertaken. In a total of six cases (10.9% overall) the radiographic abnormality was seen on ultrasound only. Real-time specimen sonography is a technique which is very appropriately utilized in conjunction with ultrasound guided excisions and can be easily performed either in the radiology department or the operative suite With minimal time delay. It could have particular application for lesions that are detected in younger women with dense breast parenchyma. The results of this review confirm specimen sonography to be a reliable technique. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Subcycling, or the use of different timesteps at different nodes, can be an effective way of improving the computational efficiency of explicit transient dynamic structural solutions. The method that has been most widely adopted uses a nodal partition. extending the central difference method, in which small timestep updates are performed interpolating on the displacement at neighbouring large timestep nodes. This approach leads to narrow bands of unstable timesteps or statistical stability. It also can be in error due to lack of momentum conservation on the timestep interface. The author has previously proposed energy conserving algorithms that avoid the first problem of statistical stability. However, these sacrifice accuracy to achieve stability. An approach to conserve momentum on an element interface by adding partial velocities is considered here. Applied to extend the central difference method. this approach is simple. and has accuracy advantages. The method can be programmed by summing impulses of internal forces, evaluated using local element timesteps, in order to predict a velocity change at a node. However, it is still only statistically stable, so an adaptive timestep size is needed to monitor accuracy and to be adjusted if necessary. By replacing the central difference method with the explicit generalized alpha method. it is possible to gain stability by dissipating the high frequency response that leads to stability problems. However. coding the algorithm is less elegant, as the response depends on previous partial accelerations. Extension to implicit integration, is shown to be impractical due to the neglect of remote effects of internal forces acting across a timestep interface. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Regional left ventricular (LV) dysfunction may occur in patients with coronary artery disease (CAD) in the absence of infarction, but the causes of this phenomenon are unclear. We sought to identify whether changes in regional LV function were related to stenosis severity, using sensitive new ultrasound markers of function. Methods: We studied 67 individuals with no history of infarction and with normal LV systolic function: 49 patients with CAD and 18 control subjects without CAD. All patients underwent color Doppler tissue imaging, integrated backscatter (IB), anatomic M-mode echocardiography, and strain rate imaging to detect changes in structure and function. Peak early and late diastolic myocardial velocity, cyclic variation of IB, wall thickness, and percent wall thickening were measured in each basal and mid segment. Strain rate and peak systolic strain were calculated in each wall. CAD was defined as greater than or equal to 50% diameter stenosis. Normokinetic segments (n = 354) subtended by CAD were divided according to stenosis severity into 3 groups: group 1 (subtended by 50%-69% stenosis); group 2 (subtended by 70%-98% stenosis); and group 3 (subtended by greater than or equal to99% stenosis). Each parameter in each group was compared with that in 216 segments from control subjects. Results: Segments subtended by significant CAD showed lower peak early and late diastolic myocardial velocity compared with control segments. Group 3 showed significantly lower myocardial velocities than group 2 for both peak early (4.8 +/- 1.8 vs 6.0 +/- 2.0 cm/s, P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel 2-amino-1,3-thiazole-5-carboxylates have been synthesised in high yield by unprecedented ultrasonic and thermally mediated nucleophilic displacement of bromide from ethyl 2-bromo-1,3-thiazole-5-carboxylate by primary, secondary and aryl amines.