29 resultados para System monitoring


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bioelectrical impedance measurements are widely used for the study of body composition. Commonly measurements are made at 50 kHz to estimate total body water or at low frequencies (< 10 kHz) to estimate extracellular fluid volume. These measurements can be obtained as single measurements at discrete frequencies, or as fitted data interpolated from plots of measurements made at multiple frequencies. This study compared single frequency and multiple frequency (MF) measurements taken in the intensive care environment. MF bioimpedance (4-1000 kHz) was measured on an adult with and without cardiorespiratory monitoring, and on babies in the neonatal intensive care unit. Measurements obtained at individual frequencies were plotted against frequency and examined for the presence of outlying points. Fitted data for measurements obtained at 5 kHz and 50 kHz with and without cardiorespiratory monitoring were compared. Significant artefacts were detected in measurements at approximately 50 kHz and at integral divisions of this frequency as a result of interference from cardiorespiratory monitors. Single frequency measurements taken at these frequencies may be subject to errors that would be difficult to detect without the aid of information obtained from MF measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Marathon running is growing in popularity, and many diabetic patients are participating in various marathon races all over the world each year. This study aimed to investigate the prevalence and extent of glycemic excursions (hypo- and hyperglycemic) during a marathon run in patients with well-controlled diabetes mellitus using a continuous glucose monitoring system (CGMS). Five subjects with type 1 and one patient with type 2 diabetes mellitus were monitored with the Medtronic MiniMed CGMS during the 2002 Vienna City Marathon (n = 3) or the Fernwarme run (n = 3) long distance runs of 42.19/15.8 km. All six patients finished their course. The CGSM system was well tolerated in all patients over an average duration of 34 +/- 4.0 hours and it did not limit the patients' activities. The mean running time for the Vienna city marathon was 257 +/- 8 min (247 to 274 min) and for the Fernwarme run 134 +/- 118 min (113 to 150 min). A total of 1470 blood glucose measurements (mean 245 readings per subject) were performed. During and after the marathons frequent hypo and hyperglycemic episodes with and without clinical symptoms were measured. Our data confirm that the CGMS may help to identify asymptomatic hypoglycemia or hyperglycemia during and after a long distance run. The system may also be helpful to improve our understanding about the individual changes of glucose during and after a marathon and may protect hypoglycemic or hyperglycemic periods in future races.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Regular and systematic monitoring of drug markets provides the basis for evidence-based policy. In Australia, trends in ecstasy and related drug (ERD) markets have been monitored in selected jurisdictions since 2000 and nationally since 2003, by the Party Drugs Initiative (PDI). The PDI maximises the validity of conclusions by triangulating information from (a) interviews with regular ecstasy users (REU), (b) interviews with key experts and (c) indicator data. There is currently no other system in Australia for monitoring these markets systematically; however, the value of the PDI has been constrained by the quality of available data. Difficulties in recruiting and interviewing appropriate consumers (REU) and key experts have been experienced, but largely overcome. Limitations of available indicator data from both health and law enforcement continue to present challenges and there remains considerable scope for enhancing existing routine data collection systems, to facilitate monitoring of ERD markets. With an expanding market for ecstasy and related drugs in Australia, and in the context of indicator data that continue to be limited in scope and detail, there is a strong argument for the continued collection of annual, comparable data from a sentinel group of REU, such as those recruited for the PDI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is growing community and professional concern that the Australian mental health care system requires substantial reform. In response to these concerns, a Senate Select Committee on Mental Health has been commissioned to conduct an inquiry into the provision of mental health services. The current study involved a content analysis of 725 submissions received by the Committee, and highlighted significant areas for reform. People with mental illness face difficulties in accessing mental health care, the care they do receive is of varying quality and poorly coordinated, and necessary services from other sectors, such as housing, are lacking. These problems may be exacerbated for particular groups with complex needs or heightened levels of vulnerability. The system requires reorienting towards the consumers and carers it is designed to serve, and needs stronger governance, higher levels of accountability and improved monitoring of quality. These findings are discussed in the context of the recent acknowledgement of mental health as an issue by the Council of Australian Governments (COAG), which has called for an action plan to be prepared for its consideration by June 2006.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Regular monitoring of wastewater characteristics is undertaken on most wastewater treatment plants. The data acquired during this process are usually filed and forgotten. However, systematic analysis of these data can provide useful insights into plant behaviour. Conventional graphical techniques are inadequate to give a good overall picture of how wastewater characteristics vary, with time and along the lagoon system. An approach based on the use of contour plots was devised that largely overcomes this problem. Superimposition of contour plots for different parameters can be used to gain a qualitative understanding of the nature and strength of relationships between the parameters. This is illustrated in an analysis of monitoring data for lagoon 115 East at the Western Treatment Plant, near Melbourne, Australia. In this illustrative analysis, relationships between ammonia removal rates and parameters such as chlorophyll a level and temperature are explored using a contour plot superimposition approach. It is concluded that this approach can help improve our understanding, not only of lagoon systems, but of other wastewater treatment systems as well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Understanding arterial distensibility has shown to be important in the pathogenesis of cardiovascular abnormalities like hypertension. It is also known that arterial pulse wave velocity (PWV) is a measure of the elasticity or stiffness of peripheral arterial blood vessels. However, it generally requires complex instrumentations to have an accurate measurement and not suited for continual monitoring. In this paper, it describes a simple and non-intrusive method to detect the cardiovascular pulse from a human wrist above the radial artery and a fingertip. The main components of this proposed method are a piezoelectric transducer and a photo-plethysmography circuitry. 5 healthy adults (4 male) with age ranging from 25 to 38 years were recruited. The timing consistency of the detected pulsations is first evaluated and compared to that obtained from a commercial electrocardiogram. Furthermore, the derived PWV is then assessed by the predicted values attained from regression equations of two previous similar studies. The results show good correlations (p < 0.05) and similarities for the former and latter respectively. The simplicity and non-invasive nature of the proposed method can be attractive for even younger or badly disturbed patients. Moreover, it can be used for prolonged monitoring for the comfort of the patients.