21 resultados para Stents eluidores de sirolimus
Resumo:
There is an urgent need to treat restenosis, a major complication of the treatment of arteries blocked by atherosclerotic plaque, using local delivery techniques. We observed that cross-linked fibrin (XLF) is deposited at the site of surgical injury of arteries. An antibody to XLF, conjugated to anti-restenotic agents, should deliver the drugs directly and only to the site of injury. An anti-XLF antibody (H93.7C.1D2/48; 1D2) was conjugated to heparin (using N-succinimidyl 3-(2-pyridyldithio)-propionate), low molecular weight heparin (LMWH) (adipic acid dihydrazide) and rapamycin (1-ethyl-3-(3-dimethylaminopropyl)carbodiimide/N-hydroxysuccinimide), and the conjugates purified and tested for activity before use in vivo. Rabbits had their right carotid arteries de-endothelialised and then given a bolus of 1D2-heparin, 1D2-LMWH or 1D2-rapamycin conjugate or controls of saline, heparin, LMWH, rapamycin or 1D2 (+/-heparin bolus) and sacrificed after 2 or 4 weeks (12 groups, n=6/group). Rabbits given any of the conjugates had minimal neointimal development in injured arteries, with up to 59% fewer neointimal cells than those given control drugs. Rabbits given 1D2-heparin or 1D2-LMWH had an increased or insignificant reduction in luminal area, with positive remodelling, while the medial and total arterial areas of rabbits given 1D2-rapamycin were not affected by injury. Arteries exposed to 1D2-heparin or 1D2-rapamycin had more endothelial cells than rabbits given control drugs. Thus, XLF-antibodies can site-deliver anti-restenotic agents to injured areas of the artery wall, where the conjugates can influence remodelling, re-endothelialisation and neointimal cell density, with reduced neointimal formation. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
This study investigates a stent-less local delivery system for anti-restenotic agents utilizing antibodies to cross-linked fibrin (XLF). Heparin and low molecular weight heparin (LMWH) were conjugated to an antibody to cross-linked fibrin D-dinner (1D2). Rabbit right carotid arteries were injured with a balloon catheter, then the animals were given a bolus injection of 40 mug/k,g 1D2-heparin (26-70 mug/kg heparin) or 1D2-LMWH (29-80 mug/kg LMWH) conjugates or controls of saline (0.5 ml/kg), heparin (150 U/kg), LMWH (2 mg), or 1D2 (40 mug/kg), with or without a heparin bolus and sacrificed after 2 weeks (8 groups, n = 6/group). The injured artery of rabbits given 1D2-heparin or 1D2-LMWH conjugates had reduced neointimal development, with decreased luminal narrowing and positive remodelling compared with animals given control drugs. Animals given 1D2-heparin conjugate (with a heparin bolus) had three to five times more endothelial cells than the rabbits given saline or unconjugated heparin, while rabbits given 1D2-LMWH conjugate had up to 59% fewer neointimal cells than those given unconjugated drugs. There was little difference in extracellular matrix organization or composition. Thus cross-linked fibrin-antibodies can site-deliver anti-restenotic agents to injured areas of the artery wall where they influence wall remodelling and endothelial and neointimal cell number, reducing neointimal formation without systemic complications. Local delivery of anti-restenotic agents should minimise systemic effects, bleeding complications and potentially the cost of treatment due to a single, lower dose. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objectives: Cyclosporin is an immunosuppressant drug with a narrow therapeutic window. Trough and 2-h post-dose blood samples are currently used for therapeutic drug monitoring in solid organ transplant recipients. The aim of the current study was to develop a rapid HPLC-tandem mass spectrometry (HPLC-MS) method for the measurement of cyclosporin in whole blood that was not only suitable for the clinical setting but also considered a reference method. Methods: Blood samples (50 mu L) were prepared by protein precipitation followed by C-18 solid-phase extraction while using d(12) cyclosporin as the internal standard. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface in positive ionization mode. Results: The assay was linear from 10 to 2000 mu g/L (r(2) > 0.996, n = 9). Inter-day,analytical recovery and imprecision using whole blood quality control samples at 10, 30, 400, 1500, and 2000 mu g/L were 94.9-103.5% and
Resumo:
Background: The Lescol Intervention Prevention Study (LIPS) was a multinational randomized controlled trial that showed a 47% reduction in the relative risk of cardiac death and a 22% reduction in major adverse cardiac events (MACEs) from the routine use of fluvastatin, compared with controls, in patients undergoing percutaneous coronary intervention (PCI, defined as angioplasty with or without stents). In this study, MACEs included cardiac death, nonfatal myocardial infarction, and subsequent PCI and coronary artery bypass graft. Diabetes was the greatest risk factor for MACEs. Objective: This study estimated the cost-effectiveness of fluvastatin when used for secondary prevention of MACEs after PCI in people with diabetes. Methods: A post hoc subgroup analysis of patients with diabetes from the LIPS was used to estimate the effectiveness of fluvastatin in reducing myocardial infarction, revascularization, and cardiac death. A probabilistic Markov model was developed using United Kingdom resource and cost data to estimate the additional costs and quality-adjusted life-years (QALYs) gained over 10 years from the perspective of the British National Health Service. The model contained 6 health states, and the transition probabilities were derived from the LIPS data. Crossover from fluvastatin to other lipid-lowering drugs, withdrawal from fluvastatin, and the use of lipid-lowering drugs in the control group were included. Results: In the subgroup of 202 patients with diabetes in the LIPS trial, 18 (15.0%) of 120 fluvastatin patients and 21 (25.6%) of 82 control participants were insulin dependent (P = NS). Compared with the control group, patients treated with fluvastatin can expect to gain an additional mean (SD) of 0.196 (0.139) QALY per patient over 10 years (P < 0.001) and will cost the health service an additional mean (SD) of 10 (E448) (P = NS) (mean [SD] US $16 [$689]). The additional cost per QALY gained was;(51 (US $78). The key determinants of cost-effectiveness included the probabilities of repeat interventions, cardiac death, the cost of fluvastatin, and the time horizon used for the evaluation. Conclusion: Fluvastatin was an economically efficient treatment to prevent MACEs in these patients with diabetes undergoing PCI.
Resumo:
The durability of all forms of open or percutaneous revascularisation is affected by the development of localised stenoses within the bypass graft or at the site of endarterectomy, stent or angioplasty. The reported incidence of significant restenosis has varied dependent on initial procedure, site, case mix and definition, but is greatest during the first 12 months (Table 1).1 Over the last 40 years tens of thousands of studies have been carried out in an effort to understand or reduce the incidence of restenosis, with two major mechanisms identified as being responsible for the luminal narrowing, namely intimal hyperplasia and constrictive remodelling. Intimal hyperplasia is provoked by changes in the balance of local cytokines controlling vascular smooth muscle cell (VSMC) proliferation, apoptosis and migration, brought about by endothelial or medial injury and alterations in haemodynamic forces. The overall vessel diameter reduction that occurs in constrictive remodelling is less well defined, but likely involves matrix turnover under the control of proteinases, particularly metalloproteinases.
Resumo:
A 52-year-old male with idiopathic hypereosinophilic syndrome (HES) was transferred to our institution following the development of acute respiratory failure and shock. He had previously undergone tricuspid valve replacement with bioprosthetic valves on two occasions: the initial surgery for severe native tricuspid valve stenosis and the redo surgery for severe prosthetic valve stenosis and regurgitation. Conventional imaging assessment using transoesophageal echocardiography was suboptimal and comprehensive assessment of prosthetic valve function was aided by the use of intracardiac echocardiography (ICE). ICE provided high quality 2D imaging of the prosthesis demonstrating thrombus-like material coating the inner surfaces of the prosthetic valve stents effectively forming a tunnel-like obstruction. Unusual hemodynamics secondary to severe tricuspid stenosis were demonstrated by CW Doppler with intermittent signal fusion resulting from blunted respiratory variation in the markedly elevated right atrial pressure relative to right ventricular pressure. Successful balloon valvuloplasty was performed with ICE proving highly valuable in guiding balloon position as well as monitoring the efficacy of the subsequent inflations.