61 resultados para Scale validation process


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Workflow systems have traditionally focused on the so-called production processes which are characterized by pre-definition, high volume, and repetitiveness. Recently, the deployment of workflow systems in non-traditional domains such as collaborative applications, e-learning and cross-organizational process integration, have put forth new requirements for flexible and dynamic specification. However, this flexibility cannot be offered at the expense of control, a critical requirement of business processes. In this paper, we will present a foundation set of constraints for flexible workflow specification. These constraints are intended to provide an appropriate balance between flexibility and control. The constraint specification framework is based on the concept of pockets of flexibility which allows ad hoc changes and/or building of workflows for highly flexible processes. Basically, our approach is to provide the ability to execute on the basis of a partially specified model, where the full specification of the model is made at runtime, and may be unique to each instance. The verification of dynamically built models is essential. Where as ensuring that the model conforms to specified constraints does not pose great difficulty, ensuring that the constraint set itself does not carry conflicts and redundancy is an interesting and challenging problem. In this paper, we will provide a discussion on both the static and dynamic verification aspects. We will also briefly present Chameleon, a prototype workflow engine that implements these concepts. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To establish concurrent validity, interrater and test-retest reliability of the Modified Elderly Mobility Scale (MEMS). Methods: Ninety elderly patients were scored on the MEMS. To establish concurrent validity, 75 patients MEMS scores were compared to Functional Independence Measure (FIM) scores using Spearman's correlation. Videotaped patient performances were used to establish interrater and test-retest reliability using percentage absolute agreement and intraclass correlation coefficients (ICCs). Results: The total MEMS score demonstrated a significant association with the motor (r = 0.725) and total FIM scores (r = 0.718). Absolute agreement for interrater reliability was greater than 93% for all test items, with 97 and 98% for the two new measures, respectively. Test-retest reliability demonstrated similar high levels of absolute agreement and had ICCs ranging from 0.870 to 1.0. Conclusions: The MEMS is a quick, valid and reliable test of motor function of elderly patients with a spread of functional levels.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Social Vulnerability Scale (SVS), an informant-report of social vulnerability for older adults, was piloted in a sample of 167 undergraduate students (63 male, 104 female) from the University of Queensland. Participants aged 18 - 53 (M = 25.53 years, SD = 7.83 years) completed the SVS by rating a relative or friend aged ≥50 years (M = 71.65 years, SD = 12.49 years): either someone with memory problems, stroke, dementia, or other neurological condition (n = 85); or a healthy older adult (n = 82). Excellent internal consistency and test - retest reliability were demonstrated, and the SVS effectively differentiated healthy older adults from those with a neurological condition based on proxy ratings of social vulnerability. The SVS is a potentially useful adjunct measure of older adults' capacity to reside independently. 1 *For information on using the Social Vulnerability Scale, email d.pinsker@psy.uq.edu.au or stone@psy.uq.edu.au

Relevância:

40.00% 40.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rectangular dropshafts, commonly used in sewers and storm water systems, are characterised by significant flow aeration. New detailed air-water flow measurements were conducted in a near-full-scale dropshaft at large discharges. In the shaft pool and outflow channel, the results demonstrated the complexity of different competitive air entrainment mechanisms. Bubble size measurements showed a broad range of entrained bubble sizes. Analysis of streamwise distributions of bubbles suggested further some clustering process in the bubbly flow although, in the outflow channel, bubble chords were in average smaller than in the shaft pool. A robust hydrophone was tested to measure bubble acoustic spectra and to assess its field application potential. The acoustic results characterised accurately the order of magnitude of entrained bubble sizes, but the transformation from acoustic frequencies to bubble radii did not predict correctly the probability distribution functions of bubble sizes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The results presented in this report form a part of a larger global study on the major issues in BPM. Only one part of the larger study is reported here, viz. interviews with BPM experts. Interviews of BPM tool vendors together with focus groups involving user organizations, are continuing in parallel and will set the groundwork for the identification of BPM issues on a global scale via a survey (including a Delphi study). Through this multi-method approach, we identify four distinct sets of outcomes. First, as is the focus of this report, we identify the BPM issues as perceived by BPM experts. Second, the research design allows us to gain insight into the opinions of organisations deploying BPM solutions. Third, an understanding of organizations’ misconceptions of BPM technologies, as confronted by BPM tool vendors is obtained. Last, we seek to gain an understanding of BPM issues on a global scale, together with knowledge of matters of concern. This final outcome is aimed to produce an industry driven research agenda which will inform practitioners and in particular, the research community world-wide on issues and challenges that are prevalent or emerging in BPM and related areas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dimensionless spray flux Ψa is a dimensionless group that characterises the three most important variables in liquid dispersion: flowrate, drop size and powder flux through the spray zone. In this paper, the Poisson distribution was used to generate analytical solutions for the proportion of nuclei formed from single drops (fsingle) and the fraction of the powder surface covered by drops (fcovered) as a function of Ψa. Monte-Carlo simulations were performed to simulate the spray zone and investigate how Ψa, fsingle and fcovered are related. The Monte-Carlo data was an excellent match with analytical solutions of fcovered and fsingle as a function of Ψa. At low Ψa, the proportion of the surface covered by drops (fcovered) was equal to Ψa. As Ψa increases, drop overlap becomes more dominant and the powder surface coverage levels off. The proportion of nuclei formed from single drops (fsingle) falls exponentially with increasing Ψa. In the ranges covered, these results were independent of drop size, number of drops, drop size distribution (mono-sized, bimodal and trimodal distributions), and the uniformity of the spray. Experimental data of nuclei size distributions as a function of spray flux were fitted to the analytical solution for fsingle by defining a cutsize for single drop nuclei. The fitted cutsizes followed the spray drop sizes suggesting that the method is robust and that the cutsize does indicate the transition size between single drop and agglomerate nuclei. This demonstrates that the nuclei distribution is determined by the dimensionless spray flux and the fraction of drop controlled nuclei can be calculated analytically in advance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Flow State Scale-2 (FSS-2) and Dispositional Flow Scale-2 (DFS-2) are presented as two self-report instruments designed to assess flow experiences in physical activity. Item modifications were made to the original versions of these scales in order to improve the measurement of some of the flow dimensions. Confirmatory factor analyses of an item identification and a cross-validation sample demonstrated a good fit of the new scales. There was support for both a 9-first-order factor model and a higher order model with a global flow factor. The item identification sample yielded mean item loadings on the first-order factor of .78 for the FSS-2 and .77 for the DFS-2. Reliability estimates ranged from .80 to .90 for the FSS-2, and .81 to .90 for the DFS-2. In the cross-validation sample, mean item loadings on the first-order factor were .80 for the FSS-2, and .73 for the DFS-2. Reliability estimates ranged between .80 to .92 for the FSS-2 and .78 to .86 for the DFS-2. The scales are presented as ways of assessing flow experienced within a particular event (FSS-2) or the frequency of flow experiences in chosen physical activity in general (DFS-2).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new method of poly-beta-hydroxybutyrate (PHB) extraction from recombinant E. coli is proposed, using homogenization and centrifugation coupled with sodium hypochlorite treatment. The size of PHB granules and cell debris in homogenates was characterised as a function of the number of homogenization passes. Simulation was used to develop the PHB and cell debris fractionation system, enabling numerical examination of the effects of repeated homogenization and centrifuge-feedrate variation. The simulation provided a good prediction of experimental performance. Sodium hypochlorite treatment was necessary to optimise PHB fractionation. A PHB recovery of 80% at a purity of 96.5% was obtained with the final optimised process. Protein and DNA contained in the resultant product were negligible. The developed process holds promise for significantly reducing the recovery cost associated with PHB manufacture.