29 resultados para PERMANENT MAGNETS
Resumo:
Magnetic resonance microscopy (MRM) depends on the use of high field, superconducting magnet systems for its operation. The magnets that are conventionally used are those that were initially designed for chemical structural analysis work. A novel, compact magnet designed specifically for MRM is presented here, and while preserving high field, high homogeneity conditions, has a length less than one-third that of conventional systems. This enables much better access to samples, an important consideration in many MRM experiments. As the homogeneity of a magnet is strongly dependent on its length, novel geometries and optimization techniques are required to meet the requirements of MRM in a compact system. An important outcome of the stochastic optimization performed in this work, is that the use used of a thin superconducting solenoid surrounded by counterwound disk windings provides a mechanism for drastic length reductions over conventional magnet designs. (C) 1998 American Institute of Physics.
Resumo:
The per iodic structure of business cycles suggests that significant asymmetries are present over different phases of the cycle. This paper uses markov regime-switching models with fixed and duration dependent transition probabilities to directly model expansions, contractions and durations in Australian GDP growth and unemployment growth. Evidence is found of significant asymmetry in growth rates across expansions and contractions for both series. GDP contractions exhibit duration dependence implying that as output recessions age the likelihood of switching into an expansion phase increases. Unemployment growth does not exhibit duration dependence in either phase. Evidence is also presented that non-linearities in unemployment growth are well explained by the asymmetries in the GDP growth cycle. The analysis suggests that recessions are periods of rapid and intense job destruction, that Australian unemployment tends to ratchet up in recessionary periods and, in contrast to US and UK studies, that shocks to Australian unemployment growth are more persistent in recessions than expansions. [E37 C5 C41].
Resumo:
Dendritic cells (DC) are likely to play a significant role in immune-mediated diseases such as autoimmunity and allergy. To date there are few treatments capable of inducing permanent remission in rheumatoid arthritis (RA) and elucidation of the role of DC may provide specific strategies for disease intervention. Dendritic cells have proven to be powerful tools for immunotherapy and investigations are under way to determine their clinical efficacy in transplantation and viral and tumour immunotherapy. The present review will focus on the current view of DC and their role in autoimmunity, in particular RA. Two possible roles for DC in the pathogenesis of RA will be proposed, based on recent advances in the field.
Resumo:
This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 1999 Academic Press.
Resumo:
Magnetic resonance imaging (MRI) relies on the physical properties of unpaired protons in tissues to generate images. Unpaired protons behave like tiny bar magnets and will align themselves in a magnetic field. Radiofrequency pulses will excite these aligned protons to higher energy states. As they return to their original state, they will release this energy as radio waves. The frequency of the radio waves depends on the local magnetic field and by varying this over a subject, it is possible to build the images we are familiar with. In general, MRI has not been sufficiently sensitive or specific in the assessment of diffuse liver disease for clinical use. However, because of the specific characteristics of fat and iron, it may be useful in the assessment of hepatic steatosis and iron overload. Magnetic resonance imaging is useful in the assessment of focal liver disease, particularly in conjunction with contrast agents. Haemangiomas have a characteristic bright appearance on T-2 weighted images because of the slow flowing blood in dilated sinusoids. Focal nodular hyperplasia (FNH) has a homogenous appearance, and enhances early in the arterial phase after gadolinium injection, while the central scar typically enhances late. Hepatic adenomas have a more heterogenous appearance and also enhance in the arterial phase, but less briskly than FNH. Hepatocellular carcinoma is similar to an adenoma, but typically occurs in a cirrhotic liver and has earlier washout of contrast. The appearance of metastases depends on the underlying primary malignancy. Overall, MRI appears more sensitive and specific than computed tomography with contrast for the detection and evaluation of malignant lesions. (C) 2000 Blackwell Science Asia Pty Ltd.
Resumo:
A major challenge associated with using large chemical libraries synthesized on microscopic solid support beads is the rapid discrimination of individual compounds in these libraries. This challenge can be overcome by encoding the beads with 1 mum silica colloidal particles (reporters) that contain specific and identifiable combinations of fluorescent byes. The colored bar code generated on support beads during combinatorial library synthesis can be easily, rapidly, and inexpensively decoded through the use of fluorescence microscopy. All reporters are precoated with polyelectrolytes [poly(acrylic acid), PAA, poly(sodium 4-styrenesulfonate PSSS, polyethylenimine, PEI, and/or poly(diallyldimethylammonium chloride), PDADMAC] with the aim of enhancing surface charge, promoting electrostatic attraction to the bead, and facilitating polymer bridging between the bead and reporter for permanent adhesion. As shown in this article, reporters coated with polyelectrolytes clearly outperform uncoated reporters with regard to quantity of attached reporters per bead (54 +/- 23 in 2500 mum(2) area for PEI/PAA coated and 11 +/- 6 for uncoated reporters) and minimization of cross-contamination (1 red reporter in 2500 mum(2) area of green-labeled bead for PEI/PAA coated and 26 +/- 15 red reporters on green-labeled beads for uncoated reporters after 10 days). Examination of various polyelectrolyte systems shows that the magnitude of the xi -potential of polyelectrolyte-coated reporters (-64 mV for PDADMAC/PSSS and -42 mV for PEI/PAA-coated reporters) has no correlation with the number of reporters that adhere to the solid support beads (21 +/- 16 in 2500 mum(2) area for PDADMAC/PSSS and 54 +/- 23 for PEI/PAA-coated reporters). The contribution of polymer bridging to the adhesion has a far greater influence than electrostatic attraction and is demonstrated by modification of the polyelectrolyte multilayers using gamma irradiation of precoated reporters either in aqueous solution or in polyelectrolyte solution.
Resumo:
In a magnetic resonance imaging equipment, gradient and shim coils are needed to produce a spatially varying magnetic field throughout the sample being imaged. Such coils consist of turns of wire wound on the surface of a cylindrical tube. Shim coils in particular, must sometimes be designed to produce complicated magnetic fields to correct for impurities. Streamline patterns for shim coils are much more complicated than those for gradient coils, In this work we present a detailed analysis of streamline methods and their application to shim coil design, A method is presented for determining the winding patterns to generate these complicated fields. (C) 2002 John Wiley & Sons, Inc.
Resumo:
Background and Purpose-Few reliable estimates of the long-term functional outcome after stroke are available. This population-based study aimed to describe disability, dependency, and related independent prognostic factors at 5 years after,a first-ever stroke in patients in Perth, Western Australia. Methods-All individuals with a suspected acute stroke who were resident in a geographically defined region (population, 138 708) of Perth, Western Australia, were registered prospectively and assessed according to standardized diagnostic criteria over a period of 18 months in 1989 to 1990. Patients were followed up prospectively at 4 and 12 months and 5 years after the index event. Results-There were 370 cases of first-ever stroke, and 277 patients survived to 30 days. Of these early survivors, 152 (55%) were alive at 5 years, and among those who were neither institutionalized (n=146) nor disabled (n=129) at the time of their stroke, 21 (14%) were institutionalized in a nursing home, and 47 (36%) were disabled. The most important predictors of death or disability at 5 years were increasing age, baseline disability defined by a Barthel Index score of <20/20 (odds ratio [OR], 6.3; 95% confidence interval [CI], 2.7 to 14), moderate hemiparesis (OR, 2.7. 95% CI, 1.1 to 6.2), severe hemiparesis (OR, 4.5; 95% CI, 1.1 to 19), and recurrent stroke (OR, 9.4; 95% CI, 3.0 to 30). A low level of activity before the stroke was a significant predictor of institutionalization, and subsequent recurrent stroke was a consistent, independent predictor of institutionalization, disability, and death or institutionalization, increasing the odds of each of these 3 adverse outcomes by 5- to 15-fold. Conclusions-Among 30-day survivors of first-ever stroke, about half survive 5 years; of survivors, one third remain disabled, and I in 7 are in permanent institutional care. The major modifiable predictors of poor long-term outcome are a low level of activity before the stroke and subsequent recurrent stroke. Efforts to increase physical activity among the elderly and to prevent recurrent stroke in survivors of a first stroke are likely to reduce the long-term burden of cerebrovascular disease.
Resumo:
AlSi7Mg0.35 alloy was cast into permanent moulds using different pouring temperatures (725 to 625degreesC). As the pouring temperature decreased, the as-cast microstructure changed from a coarse dendritic structure, through fine equiaxed grains to fine rosette-like grains. The as-cast materials were then partially remelted and isothermally held at 580degreesC prior to semisolid casting into a stepped die. The feedstock material cast from a high temperature filled only half the die, with severe segregation and other defects. The low-temperature-poured material completely filled the die with negligible porosity. The quality of semisolid castings is significantly affected by the microstructure of the semisolid feedstock material that arises from a combination of as-cast and subsequent thermal treatment conditions. The paper describes (a) the influence of pouring temperature on the microstructure of feedstock; (b) microstructure evolution through remelting and (c) the quality of semisolid castings produced with this material. For A17Si0.35Mg alloy, low temperature pouring in the range of 625-650degreesC followed by suitable isothermal holding treatment can result in good quality semisolid casting.
Resumo:
Motivated by the unconventional properties and rich phase diagram of NaxCoO2 we consider the electronic and magnetic properties of a two-dimensional Hubbard model on an isotropic triangular lattice doped with electrons away from half-filling. Dynamical mean-field theory (DMFT) calculations predict that for negative intersite hopping amplitudes (t < 0) and an on-site Coulomb repulsion, U, comparable to the bandwidth, the system displays properties typical of a weakly correlated metal. In contrast, for t > 0 a large enhancement of the effective mass, itinerant ferromagnetism, and a metallic phase with a Curie-Weiss magnetic susceptibility are found in a broad electron doping range. The different behavior encountered is a consequence of the larger noninteracting density of states (DOS) at the Fermi level for t > 0 than for t < 0, which effectively enhances the mass and the scattering amplitude of the quasiparticles. The shape of the DOS is crucial for the occurrence of ferromagnetism as for t > 0 the energy cost of polarizing the system is much smaller than for t < 0. Our observation of Nagaoka ferromagnetism is consistent with the A-type antiferromagnetism (i.e., ferromagnetic layers stacked antiferromagnetically) observed in neutron scattering experiments on NaxCoO2. The transport and magnetic properties measured in NaxCoO2 are consistent with DMFT predictions of a metal close to the Mott insulator and we discuss the role of Na ordering in driving the system towards the Mott transition. We propose that the Curie-Weiss metal phase observed in NaxCoO2 is a consequence of the crossover from a bad metal with incoherent quasiparticles at temperatures T > T-* and Fermi liquid behavior with enhanced parameters below T-*, where T-* is a low energy coherence scale induced by strong local Coulomb electron correlations. Our analysis also shows that the one band Hubbard model on a triangular lattice is not enough to describe the unusual properties of NaxCoO2 and is used to identify the simplest relevant model that captures the essential physics in NaxCoO2. We propose a model which allows for the Na ordering phenomena observed in the system which, we propose, drives the system close to the Mott insulating phase even at large dopings.
Resumo:
In seeking to increase the flexibility of their use of employee time, employers can pursue strategies based on the employment of casual and part-time workers (numerical flexibility) or strategies based on ad hoc variation of the working hours of permanent employees (working time flexibility). Patterns of flexibility strategies and their implications are examined in the context of a highly feminised sector of work-clerical and administrative employment in law and accounting firms. We consider whether, as is often assumed, working time flexibility strategies are generally better for employees because they avoid the substitution of core, high quality jobs with the peripheral, relatively insecure employment often associated with casualisation. Analysing data drawn from a survey of law and accounting firms, we argue that there are three distinct flexibility strategies adopted by employers, and that the choice of strategy is influenced by the size of the firm and the extent of feminisation. The quality of employment conditions associated with each strategy is investigated through an analysis of the determinants of training provision for clerical and administrative workers. Rather than an expected simple linear relationship between increasing casualisation and decreasing training provision, we find that firm size and feminisation are implicated. Larger firms that tend to employ at least some men and use a combination of working time and numerical flexibility strategies tend to provide more training than the small, more fully feminised firms that tend to opt for either casualisation or working time flexibility strategies. This suggests that, from an employee perspective, working time flexibility may not be as benevolent as is often thought.
Resumo:
As nuclear magnetic resonance imaging and spectroscopy move inexorably toward higher field-strength magnets in search of improved signal-to-noise ratio, spectral resolution, and spatial resolution, the way in which radiofrequency (RF) probes are designed changes. At higher frequencies, resonant cavities become the favored RF ''coil'' type and may be built using streamline elements to reduce the inductance of the system. In modeling such systems, the quasi-static approach of assuming that current flows evenly in all conductor cross sections and that adjacent conductors do not affect each other becomes less reasonable. The proximity of RF conductors in resonators typically causes RF eddy currents to flow, whereby the current density in each rung is altered by the RF fields generated by nearby conductors. The proper understanding and prediction of how resonators will perform require a model of the current densities flowing in conducting sections, including all RF eddy current effects. Very few models of this type have been presented in the literature. This article presents an overview of one such model and of how it may be applied to a variety of resonators, both shielded and unshielded, circular, and elliptical, in cross section. Results are presented from a shielded head coil operating at 2 tesla. (C) 1997 John Wiley & Sons, Inc.
Resumo:
A methodology, based on a combination of routinely performed analyses and investigation of fundamental charge and anion sorption properties, was used to characterize the soils of the humid forest zone of Cameroon, In general, the soils have about 2 cmol kg(-1) permanent negative charge, with about 1 cmol kg(-1) from variable-charge sources at current soil pH values, Furthermore, they are impoverished with respect to Ca, Mg, and K, while Al frequently dominates the exchange complex. Thus, the ability of these soils to retain base cations is more limited than is suggested by the cation-exchange capacity (CEC), Therefore we propose the concept of a degradation index (DI) defined as: DI = 100(CEC5.5 - sum of basic cations)/CEC5.5, where CEC5.5 is the CEC measured at pH 5.5, This index encompasses degradation a soil may have experienced from natural or man-made causes, Extractable PO4 concentrations are considered very low and the soils have a moderate to high capacity to fix added PO4. Surface soil SO4 concentrations are considered marginal to deficient for plant growth, though adequate reserves of SO4 are held in the subsoil by SO4 sorption, The approach used demonstrated that the five morphologically different soil profile classes identified in the zone have similar chemical characteristics. Thus, the results of experimentation conducted on one of the soil profile classes will be applicable throughout the zone, Furthermore, the approach has provided a means of identifying comparable soil types in other parts of the world and will guide technology transfer, The analytical methods used in this study are relatively simple and require no specialized equipment, and are therefore within the capabilities of many laboratories in the developing world.