47 resultados para PERCUTANEOUS-ABSORPTION
Resumo:
Objective To investigate the effect of lipophilicity on the percutaneous penetration of a homologous series of alcohols through canine skin Design Skin harvested from Greyhound thorax was placed in Franz-type diffusion cells and the in vitro passage of radio-labelled (C-14) alcohols (ethanol, butanol, hexanol and octanol (Log P 0.19 - 3.0)) through separate skin sections was measured in replicates of five. Permeability coefficient (k(P), cm/h), maximum flux (J(max), mol/cm(2)/h) and residue remaining within the skin were determined. Results The k(P) increased with increasing lipophilicity (6.2 x 10(-4) +/- 1.6 x 10(-4) cm/h for ethanol to 1.8 x 10(-2) 3.6 x 10(-3) cm/h for octanol). Alcohol residues remaining within each skin sample followed a similar pattern. An exponential decrease in Jmax with increasing lipophilicity was observed. Conclusion Changes in canine skin permeability occur with increasing alcohol lipophilicity. This finding has practical consequences for the design of topical formulations and optimisation of drug delivery through animal skin.
Resumo:
Purpose. As reductions in dermal clearance increase the residence time of solutes in the skin and underlying tissues we compared the topical penetration of potentially useful vasoconstrictors (VCs) through human epidermis as both free bases and ion-pairs with salicylic acid (SA). Methods. We determined the in vitro epidermal flux of ephedrine, naphazoline, oxymetazoline, phenylephrine, and xylometazoline applied as saturated solutions in propylene glycol: water (1: 1) and of ephedrine, naphazoline and tetrahydrozoline as 10% solutions of 1: 1 molar ratio ion-pairs with SA in liquid paraffin. Results. As free bases, ephedrine had the highest maximal flux, Jmax = 77.4 +/- 11.7 mug/cm(2)/h, being 4-fold higher than tetrahydrozoline and xylometazoline, 6-fold higher than phenylephrine, 10-fold higher than naphazoline and 100-fold higher than oxymetazoline. Stepwise regression of solute physicochemical properties identified melting point as the most significant predictor of flux. As ion-pairs with SA, ephedrine and naphazoline had similar fluxes (11.5 +/- 2.3 and 12.0 +/- 1.6 mug/cm(2)/h respectively), whereas tetrahydrozoline was approximately 3-fold slower. Corresponding fluxes of SA from the ion-pairs were 18.6 +/- 0.6, 7.8 +/- 0.8 and 1.1 +/- 0.1 respectively. Transdermal transport of VC's is discussed. Conclusions. Epidermal retention of VCs and SA did not correspond to their molar ratio on application and confirmed that following partitioning into the stratum corneum, ion-pairs separate and further penetration is governed by individual solute characteristics.
Resumo:
The reservoir function of the skin is an important determinant of the duration of action of a topical solute. The reservoir can exist in the stratum corneum, in the viable avascular tissue (viable epidermis and supracapillary dermis) and in the dermis. A steroid reservoir in the stratum corneum has been demonstrated by the reactivation of a vasoconstrictor effect by occlusion or application of a placebo cream to the skin some time after the original topical application of steroid. Other solutes have also been reported to show a reservoir effect in the skin after topical application. A simple compartmental model is used to understand why reactivation of vasoconstriction some time after a topical steroid application shows dependency on time, topical solute concentration and the product used to cause reactivation. The model is also used to show which solutes are likely to show a reservoir effect and could be potentially affected by desquamation, especially when the turnover of the skin is abnormally rapid. A similar form of the model can be used to understand the promotion of reservoir function in the viable tissue and in the dermis in terms of effective removal by blood perfusing the tissues. Copyright (C) 2004 S. Karger AG, Basel.
Resumo:
One of the most important determinants of dermatological and systemic penetration after topical application is the delivery or flux of solutes into or through the skin. The maximum dose of solute able to be delivered over a given period of time and area of application is defined by its maximum flux (J(max), mol per cm(2) per h) from a given vehicle. In this work, J(max) values from aqueous solution across human skin were acquired or estimated from experimental data and correlated with solute physicochemical properties. Whereas epidermal permeability coefficients (k(p)) are optimally correlated to solute octanol-water partition coefficient (K-ow) and molecular weight (MW) was found to be the dominant determinant of J(max) for this literature data set: log J(max)=-3.90-0.0190MW (n=87, r(2)=0.847, p
Resumo:
In vitro measurements of skin absorption are an increasingly important aspect of regulatory studies, product support claims, and formulation screening. However, such measurements are significantly affected by skin variability. The purpose of this study was to determine inter- and intralaboratory variation in diffusion cell measurements caused by factors other than skin. This was attained through the use of an artificial (silicone rubber) rate-limiting membrane and the provision of materials including a standard penetrant, methyl paraben (MP), and a minimally prescriptive protocol to each of the 18 participating laboratories. Standardized calculations of MP flux were determined from the data submitted by each laboratory by applying a predefined mathematical model. This was deemed necessary to eliminate any interlaboratory variation caused by different methods of flux calculations. Average fluxes of MP calculated and reported by each laboratory (60 +/- 27 mug cm(-2) h(-1), n = 25, range 27-101) were in agreement with the standardized calculations of MP flux (60 +/- 21 mug cm(-2) h(-1), range 19-120). The coefficient of variation between laboratories was approximately 35% and was manifest as a fourfold difference between the lowest and highest average flux values and a sixfold difference between the lowest and highest individual flux values. Intra-laboratory variation was lower, averaging 10% for five individuals using the same equipment within a single laboratory. Further studies should be performed to clarify the exact components responsible for nonskin-related variability in diffusion cell measurements. It is clear that further developments of in vitro methodologies for measuring skin absorption are required. (C) 2005 Wiley-Liss, Inc.
Resumo:
An increasing number of formulations are applied to equine skin, yet variable penetration can affect efficacy, or the incidence of adverse effects, or both. To investigate the effects of common methods of skin preparation on transdermal drug penetration in vitro, we clipped, harvested, and froze skin samples from 5 Thoroughbred geldings. Thawed samples were prepared as follows: control (no preparation); cleaned with aqueous chlorhexidine (Aq-C, 0.1% w/v); cleaned with alcoholic chlorhexidine (Al-C, 0.5% w/v); shaved (Sh); or tape-stripped (Ta) with the use of adhesive tape. The samples were then placed in diffusion cells, and 2 g of methylsalicylate (MeSa) gel (Dencorub) was applied to the stratum corneum side. The penetration of MeSa and its analyte, salicylate (Sa), through the skin samples was measured over 10 h. Compared with control skin, significantly more MeSa penetrated through skin prepared with Al-C or Sh (P < 0.01) or with Aq-C or Ta (P < 0.05), and significantly more Sa was recovered in the receptor phase from skin prepared with Aq-C, Al-C, or Sh (P < 0.05) or with Ta (P < 0.01). A significantly higher rate of penetration and shorter lag time were also noted for MeSa with all the prepared skin samples, compared with the control samples. The results show that clinical techniques routinely used to clean or prepare skin can significantly affect the rate and extent of penetration of a topically applied drug. This may result in greater systemic availability of active drug, which could lead to enhanced efficacy and, possibly, a higher incidence of adverse effects.
Resumo:
The effects of three vehicles, phosphate-buffered saline (PBS), ethanol (50% in PBS w/w) and propylene glycol (50% in PBS w/w) on in vitro transdermal penetration of testosterone was investigated in the horse. Skin was harvested from the thorax of five Thoroughbred horses after euthanasia and stored at -20 degrees C until required. The skin was then defrosted and placed into Franz-type diffusion cells, which were maintained at approximately 32 degrees C by a water bath. Saturated solutions of testosterone, containing trace amounts of radiolabelled [C-14]testosterone, in each vehicle were applied to the outer (stratum corneum) surface of each skin sample and aliquots of receptor fluid were collected at 0, 2, 4, 8, 16, 20, 22 and 24 h and analysed for testosterone by scintillation counting. The maximum flux (J(max)) of testosterone was significantly higher for all sites when testosterone was dissolved in a vehicle containing 50% ethanol or 50% propylene glycol, compared to PBS. In contrast, higher residues of testosterone were found remaining within the skin when PBS was used as a vehicle. This study shows that variability in clinical response to testosterone could be expected with formulation design.
Resumo:
Little is known about the transdermal penetration of hydrocortisone in the horse and, although commercial formulations containing hydrocortisone are registered for topical use in the horse, there have been no studies investigating the movement of this glucocorticoid through different regions of equine skin. Skin was harvested from the thorax, groin and leg (dorsal metacarpal) regions of five Thoroughbred geldings and frozen (-20 degrees C) until required. Defrosted skin was placed in Franz-type diffusion cells and the amount of radiolabelled (H-3) hydrocortisone, in a saturated solution of unlabelled hydrocortisone in 50% ethanol (w/w), which penetrated through and remained within skin samples was measured over 24 h. Significantly higher (P < 0.001) maximum flux (J(max); mol/cm(2)/h) was measured when hydrocortisone was applied to skin from the leg, compared to thorax and groin, although significantly less hydrocortisone (P < 0.001) was retained within skin from the leg at 24 h. Topical application of hydrocortisone in a vehicle containing ethanol would penetrate faster through leg skin from the lower leg when compared with the thorax or groin, which depending on cutaneous blood flow, may result in higher systemic drug concentrations or greater efficiency in treating local inflamed tissue.
Resumo:
The effects of the vehicles phosphate-buffered saline (PBS), ethanol (EtOH; 50% in PBS w/w) and propylene glycol (PG; 50% in PBS w/w) and the region of administration on in vitro transdermal penetration of testosterone was investigated in the dog. Skin was harvested from the thorax, neck (dorsal part) and groin regions of greyhounds after euthanasia and stored at -20 degrees C until required. The skin was then de-frosted and placed into Franz-type diffusion cells which were maintained at approximately 32 degrees C by a water-bath. Saturated solutions of testosterone, containing trace amounts of radiolabelled (C-14) testosterone, in each vehicle were applied to the outer (stratum corneum) surface of each skin sample and aliquots of receptor fluid were collected at 0, 2, 4, 8, 16, 20, 22 and 24 h and analysed for testosterone by scintillation counting. The maximum flux (J(max)) of testosterone was significantly higher for all sites when dissolved in a vehicle containing 50% EtOH or 50% PG, compared to PBS. In contrast, higher residues of testosterone were found remaining within the skin when PBS was used as a vehicle. This study shows that variability in percutaneous penetration of testosterone could be expected with formulation design and site of application. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
The use of topical pharmaceutical formulations is increasingly popular in veterinary medicine. A potential concern is that not all formulations are registered for the intended species, yet current knowledge strongly suggests that simple extrapolation of transdermal drug pharmacokinetics and pharmacodynamics between species, including humans, cannot be done. In this review, an overview is provided of the underlying basic principles determining the movement of topically applied molecules into and through the skin. Various factors that may affect transdermal drug penetration between species, between individuals of a particular species and regional differences in an individual are also discussed. A good understanding of the basic principles of transdermal drug delivery is critical to avoid adverse effects or lack of efficacy when applying topical formulations in veterinary medicine. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
The effect of region of application on the percutaneous penetration of solutes with differing lipophilicity was investigated in canine skin. Skin from the thorax, neck, back, groin, and axilla regions was harvested from Greyhound dogs and placed in Franz-type diffusion cells. Radiolabelled (C-14) ethanol (Log P 0.19) or hexanol (Log P 1.94) was applied to each skin section for a total of 5 h. The permeability coefficient (k(P), cm h(-1)) and residue of alcohol remaining in the skin were significantly (P = 0.001) higher for hexanol compared to ethanol. In contrast, ethanol had a far greater maximum flux (J(max), mol (cm(2))(-1) h(-1)) than hexanol (P = 0.001). A comparison of regional differences shows the k(P) and Jmax for ethanol in the groin was significantly lower (P = 0.035) than the back. The k(P) and Jmax for hexanol were significantly higher (P = 0.001) in the axilla than the other four skin sites. An understanding of factors influencing percutaneous drug movement is important when formulating topical preparations for the dog. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Quasar (QSO) absorption spectra provide an extremely useful probe of possible cosmological variation in various physical constants. Comparison of H i 21-cm absorption with corresponding molecular (rotational) absorption spectra allows us to constrain variation in , where α is the fine-structure constant and gp is the proton g-factor. We analyse spectra of two QSOs, PKS 1413+135 and TXS 0218+357, and derive values of at absorption redshifts of and 0.6847 by simultaneous fitting of the H i 21-cm and molecular lines. We find and respectively, indicating an insignificantly smaller y in the past. We compare our results with other constraints from the same two QSOs given recently by Drinkwater et al. and Carilli et al., and with our recent optical constraints, which indicated a smaller α at higher redshifts.
Resumo:
The Mellow and Autler-Townes probe absorption spectra of a three-level atom in a cascade configuration with the lower transition coherently driven and also coupled to a narrow bandwidth squeezed-vacuum field are studied. Analytical studies of the modifications caused by the finite squeezed-vacuum bandwidth to the spectra are made for the case when the Rabi frequency of the driving field is much larger than the natural linewidth. The squeezed vacuum center frequency and the driving laser frequency are assumed equal. We show that the spectral features depend on the bandwidth of a squeezed vacuum field and whether the sources of the squeezing field are degenerate (DPA) or nondegenerate (NDPA) parametric amplifiers. In a broadband or narrow bandwidth squeezed vacuum generated by a NDPA, the central component of the Mellow spectrum can be significantly narrower than that in the normal vacuum. When the source of the squeezed vacuum is a DPA, the central feature is insensitive to squeezing. The Rabi sidebands, however, can be significantly narrowed only in the squeezed vacuum produced by the DPA. The two lines of the Autler-Townes absorption spectrum can be narrowed only in a narrow bandwidth squeezed vacuum, whereas they are independent of the phase and are always broadened in a broadband squeezed vacuum.
Resumo:
The Parkes Half-Jansky Flat-Spectrum Sample contains a large number of sources with unusually red optical-to-near-infrared (NIR) continua. If this is to be interpreted as extinction by dust in the line of sight, then associated material might also give rise to absorption in the soft X-ray regime. This hypothesis is tested using broadband (0.1-2.4 keV) data from the ROSAT All-Sky Survey. Significant (>3 sigma confidence level) correlations between the optical (and NIR)-to-soft X-ray continuum slope and optical extinction are found in the data, consistent with absorption by material with metallicity and a range in the gas-to-dust ratio as observed in the local ISM. Under this simple model, the soft X-rays are absorbed at a level consistent with the range of extinctions (0 < A(V) < 6 mag) implied by the observed optical reddening. Excess X-ray absorption by warm (ionized) gas, (i.e., a warm absorber) is not required by the data.