44 resultados para Online and off-line diagnosis and monitoring methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of the new TOGA (titration and off-gas analysis) sensor for the detailed study of biological processes in wastewater treatment systems is outlined. The main innovation of the sensor is the amalgamation of titrimetric and off-gas measurement techniques. The resulting measured signals are: hydrogen ion production rate (HPR), oxygen transfer rate (OTR), nitrogen transfer rate (NTR), and carbon dioxide transfer rate (CTR). While OTR and NTR are applicable to aerobic and anoxic conditions, respectively, HPR and CTR are useful signals under all of the conditions found in biological wastewater treatment systems, namely, aerobic, anoxic and anaerobic. The sensor is therefore a powerful tool for studying the key biological processes under all these conditions. A major benefit from the integration of the titrimetric and off-gas analysis methods is that the acid/base buffering systems, in particular the bicarbonate system, are properly accounted for. Experimental data resulting from the TOGA sensor in aerobic, anoxic, and anaerobic conditions demonstrates the strength of the new sensor. In the aerobic environment, carbon oxidation (using acetate as an example carbon source) and nitrification are studied. Both the carbon and ammonia removal rates measured by the sensor compare very well with those obtained from off-line chemical analysis. Further, the aerobic acetate removal process is examined at a fundamental level using the metabolic pathway and stoichiometry established in the literature, whereby the rate of formation of storage products is identified. Under anoxic conditions, the denitrification process is monitored and, again, the measured rate of nitrogen gas transfer (NTR) matches well with the removal of the oxidised nitrogen compounds (measured chemically). In the anaerobic environment, the enhanced biological phosphorus process was investigated. In this case, the measured sensor signals (HPR and CTR) resulting from acetate uptake were used to determine the ratio of the rates of carbon dioxide production by competing groups of microorganisms, which consequently is a measure of the activity of these organisms. The sensor involves the use of expensive equipment such as a mass spectrometer and requires special gases to operate, thus incurring significant capital and operational costs. This makes the sensor more an advanced laboratory tool than an on-line sensor. (C) 2003 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Recent major epidemiological studies have adopted increasingly multidimensional approaches to assessment. Several of these have included some assessment of perceived need for mental health care. The Australian National Survey of Mental Health and Wellbeing, conducted in 1997, included a particularly detailed examination of this construct, with an instrument with demonstrated reliability and validity. Methods. A clustered probability sample of 10641 Australians responded to the field questionnaire for this survey, including questions on perceived need either where there had been service utilization, or where a disorder was detected by administration of sections of the Composite International Diagnostic Interview. The confidentialized unit record file generated from the survey was analysed for determinants of perceived need. Results. Perceived need is increased in females, in people in the middle years of adulthood, and in those who have affective disorders or co-morbidity. Effects of diagnosis and disability can account for most of the differences in gender specific rates. With correction for these effects through regression, there is less perceived need for social interventions and possibly more for counselling in females; disability is confirmed as strongly positively associated with perceived need, as are the presence of affective disorders or co-morbidity. Conclusions. The findings of this study underscore the imperative for mental health services to be attentive and responsive to consumer perceived need. The substantial majority of people who are significantly disabled by mental health problems are among those who see themselves as having such needs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Diagnosis of the HIV-associated lipodystrophy syndrome is based on clinical assessment, in lack of a consensus about case definition and reference methods. Three bedside methods were compared in their diagnostic value for lipodystrophy. Patients and Methods. Consecutive HIV-infected outpatients (n = 278) were investigated, 128 of which also had data from 1997 available. Segmental bioelectrical impedance analysis (BIA) and waist, hip and thigh circumferences were performed. Changes in seven body regions were rated by physicians and patients using linear analogue scale assessment (LASA). Diagnostic cut-off values were searched by receiver operator characteristics. Results. Lipodystrophy was diagnosed in 85 patients (31%). BIA demonstrated higher fat-free mass in patients with lipodystrophy but not after controlling for body mass index and sex. Segmental BIA was not superior to whole body BIA in detecting lipodystrophy. Fat-free mass increased from 1997 to 1999 independent from lipodystrophy. Waist-hip and waist-thigh ratios were higher in patients with lipodystrophy. BIA, anthropometry and LASA did not provide sufficient diagnostic cut-off values for lipodystrophy. Agreement between methods, and between patient and physician rating, was poor. Conclusion: These methods do not fulfil the urgent need for quantitative diagnostic tools for lipodystrophy. BIA estimates of fat free mass may be biased by lipodystrophy, indicating a need for re-calibration in HIV infected populations. (C) 2001 Harcourt Publishers Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess the variation between neuropathologists in the diagnosis of common dementia syndromes when multiple published protocols are applied. Fourteen out of 18 Australian neuropathologists participated in diagnosing 20 cases (16 cases of dementia, 4 age-matched controls) using consensus diagnostic methods. Diagnostic criteria, clinical synopses and slides from multiple brain regions were sent to participants who were asked for case diagnoses. Diagnostic sensitivity, specificity, predictive value, accuracy and variability were determined using percentage agreement and kappa statistics. Using CERAD criteria, there was a high inter-rater agreement for cases with probable and definite Alzheimer's disease but low agreement for cases with possible Alzheimer's disease. Braak staging and the application of criteria for dementia with Lewy bodies also resulted in high inter-rater agreement. There was poor agreement for the diagnosis of frontotemporal dementia and for identifying small vessel disease. Participants rarely diagnosed more than one disease in any case. To improve efficiency when applying multiple diagnostic criteria, several simplifications were proposed and tested on 5 of the original 210 cases. Inter-rater reliability for the diagnosis of Alzheimer's disease and dementia with Lewy bodies significantly improved. Further development of simple and accurate methods to identify small vessel lesions and diagnose frontotemporal dementia is warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of thermodilution and other methods of monitoring in dogs during surgery and critical care was evaluated. Six Greyhounds were anaesthetised and then instrumented by placing a thermodilution catheter into the pulmonary artery via the jugular vein. A catheter in the dorsal pedal artery also permitted direct measurement of arterial pressures. Core body temperature (degreesC) and central venous pressure (mmHg) were measured, while cardiac output (mL/min/kg) and mean arterial pressure (mmHg) were calculated. A mid-line surgical incision was performed and the physiological parameters were monitored for a total of two hours. All physiological parameters generally declined, although significant increases (P<0.05) were noted for cardiac output following surgical incision. Central venous pressure was maintained at approximately 0mmHg by controlling an infusion of sterile saline. Core body temperature decreased from 37.1+/-0.6degreesC (once instrumented) to 36.6+/-0.60degreesC (at the end of the study), despite warming using heating pads. Physiological parameters indicative of patient viability will generally decline during surgery without intervention. This study describes an approach that can be undertaken in veterinary hospitals to accurately monitor vital signs in surgical and critical care patients.