18 resultados para Microscopic observation drug susceptibility assay (MODS)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Therapeutic monitoring with dosage individualization of sirolimus drug therapy is standard clinical practice for organ transplant recipients. For several years sirolimus monitoring has been restricted as a result of lack of an immunoassay. The recent reintroduction of the microparticle enzyme immunoassay (MEIA (R)) for sirolimus on the IMx (R) analyser has the potential to address this situation. This Study, using patient samples, has compared the MEIA (R) sirolimus method with an established HPLC-tandem mass spectrometry method (HPLC-MS/MS). An established HPLC-UV assay was used for independent cross-validation. For quality control materials (5, 11, 22 mu g/L), the MEIA (R) showed acceptable validation criteria based on intra-and inter-run precision (CV) and accuracy (bias) of < 8% and < 13%, respectively. The lower limit of quantitation was found to be approximately 3 mu g/L. The performance of the immunoassay was compared with HPLC-MS/MS using EDTA whole-blood samples obtained from various types of organ transplant recipients (n = 116). The resultant Deming regression line was: MEIA = 1.3 x HPLC-MS/MS+ 1.3 (r = 0.967, s(y/x) = 1) with a mean bias of 49.2% +/- 23.1 % (range, -2.4% to 128%; P < 0.001). The reason for the large and variable bias was not explored in this study, but the sirolimus-metabolite cross-reactivity with the MEIA (R) antibody could be a substantive contributing factor. Whereas the MEIA (R) sirolimus method may be an adjunct to sirolimus dosage individualization in transplant recipients, users must consider the implications of the substantial and variable bias when interpreting results. In selected patients where difficult clinical issues arise, reference to a specific chromatographic method may be required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid biological assay based on incubation time has been developed for determination of the potency of Newcastle disease virus strain I-2 vaccine. It is based on the observation that the interval between inoculation and the first detection of haemagglutinin (HA) depends on the titre of the vaccine inoculated. Chicken embryonated eggs were inoculated with different titres (10(9), 10(6) and 10(3) EID50/0.1 ml) of vaccine and incubated for 24 h. At hourly intervals, 5 eggs from each vaccine titre were tested for the presence of HA. The results showed that the HA activity was detected from 5, 11 and 15 h after inoculation with vaccine doses of 10(9), 10(6) and 10(3) EID50, respectively. On the basis of these results it is suggested that if there is no HA detected from 5 to 11 h after inoculation of eggs with the vaccine virus, the vaccine should not be used to vaccinate chickens as it might have an infectivity titre of less than 10(6) EID50/0.1 ml, which is equivalent to the recommended single chicken dose. It is concluded that measuring the time between inoculation of the vaccine virus and the onset of HA activity might provide an estimate of the titre of the vaccine within 24 h.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The recent emergence of a decreased susceptibility of Neisseria gonorrhoeae strains to penicillin in New Caledonia has lead clinicians to operate a change in the treatment strategy. In addition, this important health issue has emphasized the need for a rapid means of detecting penicillin resistance in N. gonorrhoeae in order to select an effective treatment and limit the spread of resistant strains. In recent years, the use of fluorescence resonance energy transfer on the LightCycler has proven to be a valuable tool for the screening of mutations occurring in the genome of various microorganisms. In this study, we developed a real-time PCR assay coupled with a fluorometric hybridization probes system to detect a penicillin resistance-associated mutation on the N. gonorrhoeae ponA gene. Following an extensive evaluation involving 136 isolates, melting curve analysis correctly evidenced a 5 degrees C T-m shift in all N. gonorrhoeae strains possessing this mutation, as determined by conventional sequencing analysis. Moreover, the mutation profiles obtained with the real-time PCR showed good correlation with the pattern of penicillin susceptibility generated with classical antibiograms. Overall, our molecular assay allowed an accurate and reproducible determination of the susceptibility to penicillin corresponding to a mutation present in all chromosomally mediated resistant strains of N. gonorrhoeae.