19 resultados para Interleukin-8 -- blood
Resumo:
We investigated the capacity of two reptiles, an agamid lizard Pogona barbata and a chelid turtle Emydura signata, to compensate for the effects of temperature by making changes in their whole blood respiratory properties. This was accomplished by measuring the P-50 (at 10, 20 and 30 degrees C), hematocrit (Hct), haemoglobin concentration ([Hb]) and mean cell haemoglobin concentration (MCHC) in field acclimatised and laboratory acclimated individuals. The acute effect of temperature on P50 in P barbata, expressed as heat of oxygenation (Delta H), ranged from -16.8 +/- 1.84 to -28.5 +/- 2.73 kJ/mole. P-50 of field acclimatised P barbata increased significantly from early spring to summer at the test temperatures of 20 degrees C (43.1 +/- 1.2 to 48.8 +/- 2.1 mmHg) and 30 degrees C (54.7 +/- 1.2 to 65.2 +/- 2.3 mmHg), but showed no acclimation under laboratory conditions. For E. signata, Delta H ranged from -31.1 +/- 6.32 to -48.2 +/- 3.59 kJ/mole. Field acclimatisation and laboratory acclimation of P-50 did not occur. However, in E. signata, there was a significant increase in [Hb] and MCHC from early spring to summer in turtles collected from the wild (1.0 +/- 0.1 to 1.7 +/- 0.2 mmol/L and 4.0 +/- 0.3 to 6.7 +/- 0.7 mmol/L, respectively). (C) 2005 Published by Elsevier Inc.
Resumo:
We report here a validated method for the quantification of a new immunosuppressant drug FTY720, using HPLC-tandem mass spectrometry. Whole blood samples (500 mu l) were subjected to liquid-liquid extraction, in the presence of an internal standard (Y-32919). Mass spectrometric detection was by selected reaction monitoring with an atmospheric pressure chemical ionization source in positive ionization mode (FTY720: m/z 308.3 -> 255.3). The assay was linear from 0.2 to 25 mu g/l (r(2) > 0.997, n = 5). The inter- and intra-day analytical recovery and imprecision for quality control samples (0.5, 7 and 15 mu g/l) were 95.8-103.2 and < 5.5%, respectively. At the lower limit of quantification (0.2 mu g/l) the interand intra-day analytical recovery was 99.0-102.8% with imprecision of < 7.6% (n = 5). The assay had a mean relative recovery of 100.5 +/- 5.8% (n = 15). Extracted samples were stable for 16 h. IFTY720 quality control samples were stable at room temperature for 16 h at 4 degrees C for at least 8 days and when taken through at least three freeze-thaw cycles. In conclusion, the method described displays analytical performance characteristics that are suitable for pharmacokinetic studies in humans. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Therapeutic monitoring with dosage individualization of sirolimus drug therapy is standard clinical practice for organ transplant recipients. For several years sirolimus monitoring has been restricted as a result of lack of an immunoassay. The recent reintroduction of the microparticle enzyme immunoassay (MEIA (R)) for sirolimus on the IMx (R) analyser has the potential to address this situation. This Study, using patient samples, has compared the MEIA (R) sirolimus method with an established HPLC-tandem mass spectrometry method (HPLC-MS/MS). An established HPLC-UV assay was used for independent cross-validation. For quality control materials (5, 11, 22 mu g/L), the MEIA (R) showed acceptable validation criteria based on intra-and inter-run precision (CV) and accuracy (bias) of < 8% and < 13%, respectively. The lower limit of quantitation was found to be approximately 3 mu g/L. The performance of the immunoassay was compared with HPLC-MS/MS using EDTA whole-blood samples obtained from various types of organ transplant recipients (n = 116). The resultant Deming regression line was: MEIA = 1.3 x HPLC-MS/MS+ 1.3 (r = 0.967, s(y/x) = 1) with a mean bias of 49.2% +/- 23.1 % (range, -2.4% to 128%; P < 0.001). The reason for the large and variable bias was not explored in this study, but the sirolimus-metabolite cross-reactivity with the MEIA (R) antibody could be a substantive contributing factor. Whereas the MEIA (R) sirolimus method may be an adjunct to sirolimus dosage individualization in transplant recipients, users must consider the implications of the substantial and variable bias when interpreting results. In selected patients where difficult clinical issues arise, reference to a specific chromatographic method may be required.
Resumo:
Central arterial waveforms and related indices of large artery properties can be determined with relative ease. This would make them an attractive adjunct in the risk stratification for cardiovascular disease. Although they have been associated with some classical risk factors and the presence of coronary disease, their prospective value in predicting cardiovascular outcomes is unknown. The present study determined the relative predictive value for cardiovascular disease-free survival of large artery properties as compared with noninvasive brachial blood pressure alone in a population of elderly female hypertensive subjects. We measured systemic arterial compliance, central systolic pressure, and carotid augmentation index in a subset of female participants in the Second Australian National Blood Pressure Study ( untreated blood pressure 169/88 +/- 12/ 8 mm Hg). There were a total of 53 defined events during a median of 4.1 years of follow-up in 484 women with complete measurements. Although baseline blood pressures at the brachial artery predicted cardiovascular disease-free survival ( hazard ratio [HR], 2.3; 95% CI, 1.3 to 4.1 for pulse pressure >= 81 versus < 81 mm Hg; P = 0.01), no such relation was found for carotid augmentation index ( HR, 0.80; 95% CI, 0.44 to 1.44; P value not significant) or systemic arterial compliance ( HR, 1.25; 95% CI, 0.72 to 2.16; P value not significant). Blood pressure, but not noninvasively measured central arterial waveforms, predict outcome in the older female hypertensive patient. Thus, blood pressure measurement alone is superior to measurement of arterial waveforms in predicting outcome in this group.