20 resultados para Impedance analysis


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: Obesity is a disease with excess body fat where health is adversely affected. Therefore it is prudent to make the diagnosis of obesity based on the measure of percentage body fat. Body composition of a group of Australian children of Sri Lankan origin were studied to evaluate the applicability of some bedside techniques in the measurement of percentage body fat. Methods: Height (H) and weight (W) was measured and BMI (W/H-2) calculated. Bioelectrical impedance analysis (BIA) was measured using tetra polar technique with an 800 mu A current of 50 Hz frequency. Total body water was used as a reference method and was determined by deuterium dilution and fat free mass and hence fat mass (FM) derived using age and gender specific constants. Percentage FM was estimated using four predictive equations, which used BIA and anthropometric measurements. Results: Twenty-seven boys and 15 girls were studied with mean ages being 9.1 years and 9.6 years, respectively. Girls had a significantly higher FM compared to boys. The mean percentage FM of boys (22.9 +/- 8.7%) was higher than the limit for obesity and for girls (29.0 +/- 6.0%) it was just below the cut-off. BMI was comparatively low. All but BIA equation in boys under estimated the percentage FM. The impedance index and weight showed a strong association with total body water (r(2)= 0.96, P < 0.001). Except for BIA in boys all other techniques under diagnosed obesity. Conclusions: Sri Lankan Australian children appear to have a high percentage of fat with a low BMI and some of the available indirect techniques are not helpful in the assessment of body composition. Therefore ethnic and/or population specific predictive equations have to be developed for the assessment of body composition, especially in a multicultural society using indirect methods such as BIA or anthropometry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Lean bodyweight (LBW) has been recommended for scaling drug doses. However, the current methods for predicting LBW are inconsistent at extremes of size and could be misleading with respect to interpreting weight-based regimens. Objective: The objective of the present study was to develop a semi-mechanistic model to predict fat-free mass (FFM) from subject characteristics in a population that includes extremes of size. FFM is considered to closely approximate LBW. There are several reference methods for assessing FFM, whereas there are no reference standards for LBW. Patients and methods: A total of 373 patients (168 male, 205 female) were included in the study. These data arose from two populations. Population A (index dataset) contained anthropometric characteristics, FFM estimated by dual-energy x-ray absorptiometry (DXA - a reference method) and bioelectrical impedance analysis (BIA) data. Population B (test dataset) contained the same anthropometric measures and FFM data as population A, but excluded BIA data. The patients in population A had a wide range of age (18-82 years), bodyweight (40.7-216.5kg) and BMI values (17.1-69.9 kg/m(2)). Patients in population B had BMI values of 18.7-38.4 kg/m(2). A two-stage semi-mechanistic model to predict FFM was developed from the demographics from population A. For stage 1 a model was developed to predict impedance and for stage 2 a model that incorporated predicted impedance was used to predict FFM. These two models were combined to provide an overall model to predict FFM from patient characteristics. The developed model for FFM was externally evaluated by predicting into population B. Results: The semi-mechanistic model to predict impedance incorporated sex, height and bodyweight. The developed model provides a good predictor of impedance for both males and females (r(2) = 0.78, mean error [ME] = 2.30 x 10(-3), root mean square error [RMSE] = 51.56 [approximately 10% of mean]). The final model for FFM incorporated sex, height and bodyweight. The developed model for FFM provided good predictive performance for both males and females (r(2) = 0.93, ME = -0.77, RMSE = 3.33 [approximately 6% of mean]). In addition, the model accurately predicted the FFM of subjects in population B (r(2) = 0.85, ME -0.04, RMSE = 4.39 [approximately 7% of mean]). Conclusions: A semi-mechanistic model has been developed to predict FFM (and therefore LBW) from easily accessible patient characteristics. This model has been prospectively evaluated and shown to have good predictive performance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The corrosion behaviour of pure magnesium in Hank's simulated body fluid (SBF) was investigated. It was found that the polarization of Mg in the SBF solution was similar to that in a NaCl aqueous solution. However, AC impedance analysis suggested that the detailed dissolution steps involved in the corrosion of Mg in the SBF could be different in terms of their rates or contributions to corrosion damage of Mg. Moreover, the corrosion rate of Mg in the SBF solution was found to be increasing with time and significant hydrogen evolution and alkalization of the SBF solution resulting from corrosion of Mg were measured in the study. The results suggested that after some proper measures are taken to retard corrosion reaction, Mg can be successfully employed as a degradable and absorbable implant material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Functional electrical impedance tomography (EIT) measures relative impedance change that occurs in the chest during a distinct observation period and an EIT image describing regional relative impedance change is generated. Analysis of such an EIT image may be erroneous because it is based on an impedance signal that has several components. Most of the change in relative impedance in the chest is caused by air movement but other physiological events such as cardiac activity change in end expiratory level or pressure swings originating from a ventilator circuit can influence the impedance signal. We obtained EIT images and signals in spontaneously breathing healthy adults, in extremely prematurely born infants on continuous positive airway pressure and in ventilated sheep on conventional mechanical or high frequency oscillatory ventilation (HFOV). Data were analyzed in the frequency domain and results presented after band pass filtering within the frequency range of the physiological event of interest. Band pass filtering of EIT data is necessary in premature infants and on HFOV to differentiate and eliminate relative impedance changes caused by physiological events other than the one of interest.