65 resultados para Hybrid urban facilities
Resumo:
This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 1999 Academic Press.
Resumo:
This paper describes a hybrid numerical method of an inverse approach to the design of compact magnetic resonance imaging magnets. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first, kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. The emphasis of this work is on the optimal design of short MRI magnets. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric MRI magnets as well as asymmetric magnets. The results highlight that the method can be used to obtain a compact MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1 m in length, significantly shorter than current designs. Viable asymmetric magnet designs, in which the edge of the homogeneous region is very close to one end of the magnet system are also presented. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00303-5].
Resumo:
A hybrid formulation for coupled pore fluid-solid deformation problems is proposed. The scheme is a hybrid in the sense that we use a vertex centered finite volume formulation for the analysis of the pore fluid and a particle method for the solid in our model. The pore fluid formally occupies the same space as the solid particles. The size of the particles is not necessarily equal to the physical size of materials. A finite volume mesh for the pore fluid flow is generated by Delaunay triangulation. Each triangle possesses an initial porosity. Changes of the porosity are specified by the translations of the mass centers of particles. Net pore pressure gradients are applied to the particle centers and are considered in the particle momentum balance. The potential of our model is illustrated by means of a simulation of coupled fracture and fluid flow developed in porous rock under biaxial compression condition.
Resumo:
To fill a gap in knowledge about the effectiveness of brief intervention for hazardous alcohol use among Indigenous Australians, we attempted to implement a randomised controlled trial in an urban Aboriginal Medical Service (AMS) as a joint AMS-university partnership. Because of low numbers of potential participants being screened, the RCT was abandoned in favour of a two-part demonstration project. Only 16 clients were recruited for follow-up in six-months, and the trial was terminated. Clinic, patient, Aboriginal health worker, and GP factors, interacting with study design factors, all contributed to our inability to implement the trial as designed. The key points to emerge from the study are that alcohol misuse is a difficult issue to manage in an Indigenous primary health care setting; RCTs involving inevitably complex study protocols may not be acceptable or sufficiently adaptable to make them viable in busy, Indigenous primary health care settings; and gold-standard RCT-derived evidence for the effectiveness of many public health interventions in Indigenous primary health care settings may never be available, and decisions about appropriate interventions will often have to be based on qualitative assessment of appropriateness and evidence from other populations and other settings.
Resumo:
In this paper we analyze a hybrid auction that combines a first-price and a Vickrey auction. We show that this auction may generate more expected revenue than a standard first-price auction. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
The purpose of this study was to investigate urban-rural differentials in Australian suicide rates, and to examine influences that previously have remained largely speculative. Suicide rates for males (all ages and young adults) were significantly higher in rural areas compared to urban areas. Urban-rural suicide rate differences in males were rendered nonsignificant after adjustment for migrant and area socioeconomic status. Adjusting for mental disorder prevalence, in addition to migrant status, reduced the excess suicide risk in rural areas; the excess was reduced further with addition of mental health service utilization. The implications of this study are that socioeconomic circumstances in rural populations contribute to higher male suicide rates compared to urban areas, but these conditions may be partly mediated by mental disorder prevalence and mental health service utilization.
Resumo:
A free-piston driver that employs entropy-raising shock processes with diaphragm rupture has been constructed, which promises significant theoretical advantages over isentropic compression. Results from a range of conditions with helium and argon driver gases are reported. Significant performance gains were achieved in some test cases. Heat losses are shown to have a strong effect on driver processes. Measurements compare well with predictions from a quasi-one-dimensional numerical code.
Resumo:
We compared the aldosterone-producing potency of the angiotensin II-sensitive wild-type aldosterone synthase genes and the ACTH-sensitive hybrid 11 beta-hydroxylase/aldosterone synthase gene by examining aldosterone, PRA, and cortisol day-curves (2-hourly levels over 24 h) in patients with familial hyperaldosteronism type I, before and during long-term (0.8-13.5 yr) glucocorticoid treatment. In 8 untreated patients, PRA levels were usually suppressed, and aldosterone correlated strongly with cortisol (r = 0.69-0.99). Fourteen studies were performed on 10 patients receiving glucocorticoid treatment that corrected hypertension, hypokalemia, and PRA suppression in all. ACTH was markedly and continuously suppressed in 6 studies, 3 of which demonstrated strong correlations between aldosterone and PRA (r = 0.77-0.92), ACTH was only partially suppressed in the remaining 8 studies; aldosterone correlated strongly: 1) with cortisol alone in 5 (r = 0.71-0.98); 2) with cortisol (r = 0.90) and PRA (r = 0.74) in one; 3) with PRA only in one (r = 0.80); and 4) with neither PRA nor cortisol in one. Unless ACTH is markedly and continuously suppressed, aldosterone is more responsive to ACTH than to renin/angiotensin II, despite the latter being unsuppressed. This is consistent with the hybrid gene being more powerfully expressed than the wild-type aldosterone synthase genes in familial hyperaldosteronism type I.