24 resultados para High-performance Liquid Chromatography-mass Spectrometry (hplc-ms)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The complex nature of venom from spider species offers a unique natural source of potential pharmacological tools and therapeutic leads. The increased interest in spider venom molecules requires reproducible and precise identification methods. The current taxonomy of the Australian Funnel-web spiders is incomplete, and therefore, accurate identification of these spiders is difficult. Here, we present a study of venom from numerous morphologically similar specimens of the Hadronyche infensa species group collected from a variety of geographic locations in southeast Queensland. Analysis of the crude venoms using online reversed-phase high performance liquid chromatography/electrospray ionisation mass spectrometry (rp-HPLC/ESI-MS) revealed that the venom profiles provide a useful means of specimen identification, from the species level to species variants. Tables defining the descriptor molecules for each group of specimens were constructed and provided a quick reference of the relationship between one specimen and another. The study revealed that the morphologically similar specimens from the southeast Queensland region are a number of different species/species variants. Furthermore, the study supports aspects of the current taxonomy with respect to the H. infensa species group. Analysis of Australian Funnel-web spider venom by rp-HPLC/ESI-MS provides a rapid and accurate method of species/species variant identification. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The role of the therapeutic drug monitoring laboratory in support of immunosuppressant drug therapy is well established, and the introduction of sirolimus (SRL) is a new direction in this field. The lack of an immunoassay for several years has restricted the availability of SRL assay services. The recent availability of a CEDIA (R) SRL assay has the potential to improve this situation. The present communication has compared the CEDIA (R) SRL method with 2 established chromatographic methods, HPLC-UV and HPLC-MS/MS. The CEDIA (R) method, run on a Hitachi 917 analyzer, showed acceptable validation criteria with within-assay precision of 9.1% and 3.3%, and bias of 17.1% and 5.8%, at SRL concentrations of 5.0 mu g/L and 20 mu g/L, respectively. The corresponding between-run precision values were 11.5% and 3.3% and bias of 7.1% and 2.9% at 5.0 mu g/L and 20 mu g/L, respectively, The lower limit of quantification was found to be 3.0 mu g/L. A series of 96 EDTA whole-blood samples predominantly from renal transplant recipients were assayed by the 3 methods for comparison. It was found that the CEDIA (R) method showed a Deming regression line of CEDIA = 1.20 X HPLC-MS/MS - 0.07 (r = 0.934, SEE = 1.47), with a mean bias of 20.4%. Serial blood samples from 8 patients included in this evaluation showed that the CEDIA (R) method reflected the clinical fluctuations in the chromatographic methods, albeit with the variable bias noted. The CEDIA (R) method on the H917 analyzer is therefore a useful adjunct to SRL dosage individualization in renal transplant recipients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Therapeutic monitoring with dosage individualization of sirolimus drug therapy is standard clinical practice for organ transplant recipients. For several years sirolimus monitoring has been restricted as a result of lack of an immunoassay. The recent reintroduction of the microparticle enzyme immunoassay (MEIA (R)) for sirolimus on the IMx (R) analyser has the potential to address this situation. This Study, using patient samples, has compared the MEIA (R) sirolimus method with an established HPLC-tandem mass spectrometry method (HPLC-MS/MS). An established HPLC-UV assay was used for independent cross-validation. For quality control materials (5, 11, 22 mu g/L), the MEIA (R) showed acceptable validation criteria based on intra-and inter-run precision (CV) and accuracy (bias) of < 8% and < 13%, respectively. The lower limit of quantitation was found to be approximately 3 mu g/L. The performance of the immunoassay was compared with HPLC-MS/MS using EDTA whole-blood samples obtained from various types of organ transplant recipients (n = 116). The resultant Deming regression line was: MEIA = 1.3 x HPLC-MS/MS+ 1.3 (r = 0.967, s(y/x) = 1) with a mean bias of 49.2% +/- 23.1 % (range, -2.4% to 128%; P < 0.001). The reason for the large and variable bias was not explored in this study, but the sirolimus-metabolite cross-reactivity with the MEIA (R) antibody could be a substantive contributing factor. Whereas the MEIA (R) sirolimus method may be an adjunct to sirolimus dosage individualization in transplant recipients, users must consider the implications of the substantial and variable bias when interpreting results. In selected patients where difficult clinical issues arise, reference to a specific chromatographic method may be required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ISCOMs have received much attention as vaccine adjuvants due to their immunostimulatory effects. They are colloidal particles typically comprised of phospholipids, cholesterol and Quil A, a crude mixture of saponins extracted from the bark of Quillaja saponaria Molina. We have previously shown that ISCOMs can be prepared by ether injection wherein an ether solution of phospholipids and cholesterol in a mass ratio of 5:2 is injected into a solution of Quil A at a mass ratio of 7 lipids: 3 Quil A. The aim of this study was firstly to isolate and characterise discrete fractions of Quil A and secondly to investigate which of these fractions were able to form ISCOMs by the method of ether injection. Six fractions of Quil A were isolated by semi-preparative reverse phase high performance liquid chromatography (RP-HPLC) and characterised by analytical HPLC, liquid chromatography tandem mass spectrometry (LC-MS) and the qualitative Liebermann- Burchard and Molisch tests for triterpenoids and carbohydrates respectively. ISCOMs were subsequently prepared from the isolated fractions by the method of ether injection and the resulting preparations characterized by photon correlation spectroscopy (PCS) and negative stain transmission electron microscopy (TEM). The molecular weights of the major compounds in the fractions ranged from ∼1200 to ∼2300 Da; all fractions tested positive for triterpenoids and saccharides and four of the fractions were identified as QS-7, QS-17, QS-18 and QS-21 by analysis (LC-MS and analytical HPLC). Injection of ether solutions of lipids into aqueous solutions of QS-17, QS-18 or QS-21 all resulted in homogeneous ISCOM dispersions. The combination of lipids and QS-7 by ether injection produced lamellae and liposomes as the prominent structures and a minor amount of ISCOMs. The remaining two hydrophilic, low molecular weight fractions of Quil A did not produce ISCOMs, instead liposomes and helical structures predominated in the samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. The aims of this study are to evaluate whether cytochrome P450 (CYP)2D1/2D2-deficient dark agouti (DA) rats and/or CYP2D1/2D2-replete Sprague-Dawley (SD) rats are suitable preclinical models of the human, with respect to mirroring the very low plasma concentrations of metabolically derived oxymorphone seen in humans following oxycodone administration, and to examine the effects of streptozotocin-induced diabetes on the pharmacokinetics of oxycodone and its metabolites, noroxycodone and oxymorphone, in both rodent strains. Methods. High-performance liquid chromatography-electrospray ionization-tandem mass spectrometry was used to quantify the serum concentrations of oxycodone, noroxycodone, and oxymorphone following subcutaneous administration of bolus doses of oxycodone (2 mg/kg) to groups of nondiabetic and diabetic rats. Results. The mean (+/- SEM) areas under the serum concentration vs. time curves for oxycodone and noroxycodone were significantly higher in DA relative to SD rats (diabetic, p < 0.05; nondiabetic, p < 0.005). Serum concentrations of oxymorphone were very low (< 6.9 nM). Conclusions. Both DA and SD rats are suitable rodent models to study oxycodone's pharmacology, as their systemic exposure to metabolically derived oxymorphone (potent mu-opioid agonist) is very low, mirroring that seen in humans following oxycodone administration. Systemic exposure to oxycodone and noroxycodone was consistently higher for DA than for SD rats showing that strain differences predominated over diabetes status.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vaccinium myrtillus or bilberry fruit is a commonly used herbal product. The usual method of determining the anthocyanin content is a single-wavelength spectrophotometric assay. Using this method, anthocyanin levels of two extracts were found to be 25% as claimed by the manufacturers. When high-performance liquid chromatography (HPLC) was used, however, one extract was found to contain 9% anthocyanins probably not derived from V. myrtillus but from an adulterant. This adulterant was subsequently identified, using HPLC, mass spectroscopy, and nuclear magnetic resonance, as amaranth, that is, 3-hydroxy-4-[(4-sulfo-1-naphthalenyl)azo]-2,7-naphthalenedisulfonic acid trisodium saltsa synthetic dark red sulfonic acid based naphthylazo dye. As described in this study, if deliberate adulteration occurs in an extract, a single-wavelength spectrophotometric assay is inadequate to accurately determine the levels of compounds such as anthocyanins. Detection of deliberate adulteration in commercial samples thus requires the use of alternative, more sophisticated, methods of analysis such as HPLC with photodiode array detection as a minimum.