17 resultados para Heating and ventilation industry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The relevance of endocrine-disrupting compounds as potential contaminants of drinking water is reviewed, particularly in the reuse of wastewater. Growing populations and increasing intensification of land and water use for industry and agriculture have increased the need to reclaim wastewater for reuse, including to supplement the drinking water supply. The variety of anthropogenic chemicals that have been identified as potential endocrine disruptors in the environment and the problems arising from their use as human and livestock pharmaceuticals, as agricultural chemicals and in industry are discussed. The potentially adverse impact of these chemicals on human health and the ecology of the natural environment are reviewed. Data for the removal of estrogenic compounds from wastewater treatment are presented, together with the comparative potencies of estrogenic compounds. The relative exposure to estrogens of women on oral contraceptives, hormone replacement therapy, and through food consumption is estimated. A brief overview of some methods available or under development for the assessment of estrogenic activity in environmental samples is provided. The review concludes with a discussion of the directions for further investigation, which include human epidemiology, methodology development, and wastewater monitoring. (C) 2006 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare the incidence of ventilator-associated pneumonia (VAP) in patients ventilated in intensive care by means of circuits humidified with a hygroscopic heat-and-moisture exchanger with a bacterial viral filter (HME) or hot-water humidification with a heater wire in both inspiratory and expiratory circuit limbs (DHW) or the inspiratory limb only (SHW). Design: A prospective, randomized trial. Setting: A metropolitan teaching hospital's general intensive care unit. Patients: Three hundred eighty-one patients requiring a minimum period of mechanical ventilation of 48 hrs. Interventions: Patients were randomized to humidification with use of an HME (n = 190), SHW (n = 94), or DHW (n = 97). Measurements and Main Results. Study end points were VAP diagnosed on the basis of Clinical Pulmonary Infection Score (CPIS) (1), HME resistance after 24 hrs of use, endotracheal tube resistance, and HME use per patient. VAP occurred with similar frequency in all groups (13%, HME; 14%, DHW; 10%, SHW; p = 0.61) and was predicted only by current smoking (adjusted odds ratio [AOR], 2.1; 95% confidence interval [CI], 1.1-3.9; p =.03) and ventilation days (AOR, 1.05; 95% Cl, 1.0-1.2; p =.001); VAP was less likely for patients with an admission diagnosis of pneumonia (AOR, 0.40; 95% Cl, 0.4-0.2; p =.04). HME resistance after 24 hrs of use measured at a gas flow of 50 L/min was 0.9 cm H2O (0.4-2.9). Endotracheal tube resistance was similar for all three groups (16-19 cm H2O min/L; p =.2), as were suction frequency, secretion thickness, and blood on suctioning (p =.32, p =.06, and p =.34, respectively). The HME use per patient per day was 1.13. Conclusions: Humidification technique does not influence either VAP incidence or secretion characteristics, but HMEs may have air-flow resistance higher than manufacturer specifications after 24 hrs of use.