57 resultados para FREQUENCY OSCILLATORY VENTILATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the accurate computation of the current densities produced in a wide-runged bi-planar radio-frequency coil is presented. The device has applications in magnetic resonance imaging. There is a set of opposing primary rungs, symmetrically placed on parallel planes and a similar arrangement of rungs on two parallel planes surrounding the primary serves as a shield. Current densities induced in these primary and shielding rungs are calculated to a high degree of accuracy using an integral-equation approach, combined with the inverse finite Hilbert transform. Once these densities are known, accurate electrical and magnetic fields are then computed without difficulty. Some test results are shown. The method is so rapid that it can be incorporated into optimization software. Some preliminary fields produced from optimized coils are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The free running linewidth of an external cavity grating feedback diode laser is on the order of a few megahertz and is limited by the mechanical and acoustic vibrations of the external cavity. Such frequency fluctuations can be removed by electronic feedback. We present a hybrid stabilisation technique that uses both a Fabry-Perot confocal cavity and an atomic resonance to achieve excellent short and long term frequency stability. The system has been shown to reduce the laser linewidth of an external cavity diode laser by an order of magnitude to 140 kHz, while limiting frequency excursions to 60 kHz relative to an absolute reference over periods of several hours. The scheme also presents a simple way to frequency offset two lasers many gigahertz apart which should find a use in atom cooling experiments, where hyperfine ground-state frequency separations are often required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Curing of diglycidyl ether of bisphenol A/diaminodiphenyl sulfone (DGEBA/DDS) epoxy resin has been effected by heating with radio frequency (RF) radiation at frequencies of 30-99 MHz. The epoxy resins can be cured rapidly at low RF power levels. Comparison of the kinetics of the RF curing with thermal curing while maintaining the same curing temperature revealed no differences. Previous differences in rates of thermal and microwave curing are believed to be due to lack of temperature control during microwave curing. For RF curing,the rate of cure, at constant power level, increases at lower RF frequency, thus emphasizing one of the principal advantages of RF curing over microwave curing. (C) 1999 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioelectrical impedance analysis has found extensive application as a simple noninvasive method for the assessment of body fluid volumes, The measured impedance is, however, not only related to the volume of fluid but also to its inherent resistivity. The primary determinant of the resistivities of body fluids is the concentration of ions. The aim of this study was to investigate the sensitivity of bioelectrical impedance analysis to bodily ion status. Whole body impedance over a range of frequencies (4-1012 kHz) of rats was measured during infusion of various concentrations of saline into rats concomitant with measurement of total body and intracellular water by tracer dilution techniques. Extracellular resistance (R-o), intracellular resistance (R-i) and impedance at the characteristic frequency (Z(c)) were calculated. R-o and Z(c) were used to predict extracellular and total body water respectively using previously published formulae. The results showed that whilst R-o and Z(c) decreased proportionately to the amount of NaCl infused, R-i increased only slightly. Impedances at the end of infusion predicted increases iu TBW and ECW of approximately 4-6% despite a volume increase of less than 0.5% in TBW due to the volume of fluid infused. These data are discussed in relation to the assumption of constant resistivity in the prediction of fluid volumes from impedance data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a single optical photon source for quantum cryptography based on the acoustoelectric effect. Surface acoustic waves (SAWs) propagating through a quasi-one-dimensional channel have been shown to produce packets of electrons that reside in the SAW minima and travel at the velocity of sound. In our scheme, the electron packets are injected into a p-type region, resulting in photon emission. Since the number of electrons in each packet can be controlled down to a single electron, a stream of single- (or N-) photon states, with a creation time strongly correlated with the driving acoustic field, should be generated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has recently been stated that the parametrization of the time variables in the one-dimensional (I-D) mixing-frequency electron spin-echo envelope modulation (MIF-ESEEM) experiment is incorrect and hence the wrong frequencies for correlated nuclear transitions are predicted. This paper is a direct response to such a claim, its purpose being to show that the parametrization in land 2-D MIF-ESEEM experiments possesses the same form as that used in other 4-pulse incrementation schemes and predicts the same correlation frequencies. We show that the parametrization represents a shearing transformation of the 2-D time-domain and relate the resulting frequency domain spectrum to the HYSCORE spectrum in terms of a skew-projection. It is emphasized that the parametrization of the time-domain variables may be chosen arbitrarily and affects neither the computation of the correct nuclear frequencies nor the resulting resolution. The usefulness or otherwise of the MIF parameters \gamma\ > 1 is addressed, together with the validity of the original claims of the authors with respect to resolution enhancement in cases of purely homogeneous and inhomogeneous broadening. Numerical simulations are provided to illustrate the main points.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a primary analysis of a large recently completed randomized trial in 915 high-risk patients undergoing major abdominal surgery, we found no difference in outcome between patients receiving perioperative epidural analgesia and those receiving IV opioids, apart from the incidence of respiratory failure. Therefore, we performed a selected number of predetermined subgroup analyses to identify specific types of patients who may have derived benefit from epidural analgesia. We found no difference in outcome between epidural and control groups in subgroups at increased risk of respiratory or cardiac complications or undergoing aortic surgery, nor in a subgroup with failed epidural block (all P > 0.05). There was a small reduction in the duration of postoperative ventilation (geometric mean [SD]: control group, 0.3 [6.5] h, versus epidural group, 0.2 [4.8] h, P = 0.048). No differences were found in length of stay in intensive care or in the hospital. There was no relationship between frequency of use of epidural analgesia in routine practice outside the trial and benefit from epidural analgesia in the trial. We found no evidence that perioperative epidural analgesia significantly influences major morbidity or mortality after major abdominal surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Superhyperfine interactions in inhomogeneously broadened paramagnetic centers are observed using a single high-turn-angle microwave pulse. The free induction signal that follows the hole-burning pulse exhibits oscillations that are distinct from the oscillatory free induction decay observable in some inhomogeneously broadened systems. It contains frequencies characteristic of the superhyperfine splittings, together with a zero frequency component. Experimental examples of the effect in both orientationally disordered (powdered) and structurally disordered (glassy) systems are presented and compared with the conceptually similar Fourier transform electron paramagnetic resonance detected nuclear magnetic resonance experiment, together with numerical simulations. (C) 2003 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Restricted cochlear lesions in adult animals result in plastic changes in the representation of the lesioned cochlea, and thus in the frequency map, in the contralateral auditory cortex and thalamus. To examine the contribution of subthalamic changes to this reorganization, the effects of unilateral mechanical cochlear lesions on the frequency organization of the central nucleus of the inferior colliculus (ICC) were examined in adult cats. Lesions typically resulted in a broad high-frequency hearing loss extending from a frequency in the range 15-22 kHz. After recovery periods of 2.5-18 months, the frequency organization of ICC contralateral to the lesioned cochlea was determined separately for the onset and late components of multiunit responses to tone-burst stimuli. For the late response component in all but one penetration through the ICC, and for the onset response component in more than half of the penetrations, changes in frequency organization in the lesion projection zone were explicable as the residue of prelesion responses. In half of the penetrations exhibiting nonresidue type changes in onset-response frequency organization, the changes appeared to reflect the unmasking of normally inhibited inputs. In the other half it was unclear whether the changes reflected unmasking or a dynamic process of reorganization. Thus, most of the observed changes were explicable as passive consequences of the lesion, and there was limited evidence for plasticity in the ICC. The implications of the data with respect to the primary locus of the changes and to the manner in which they contribute to thalamocortical reorganization are considered. (C) 2003 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our aim was to determine whether antenatal corticosteroids improve perinatal adaptation of the pulmonary circulation in lambs with lung hypoplasia (LH). LH was induced in 12 ovine fetuses between 105 and 140 days gestation (term similar to 147 days); in 6 of these the ewe was given a single dose of betamethasone (11.4 mg im) 24 hr before delivery (LH + B). All lambs, including a control group (n = 6), were delivered at similar to 140 days and ventilated for 2 hr during which arterial pressures, pulmonary blood flow (PBF), and ventilating pressure and flow were recorded. During ventilation, respiratory system compliance was lower in both LH + B and LH groups than in controls. Pulmonary vascular resistance (PVR) was lower in LH + B lambs than in LH lambs and similar to controls; PBF was reduced in LH lambs but was restored to control levels by betamethasone. The mean density of small arteries of LH + B lambs was similar to that of LH lambs (P = 0.06) and lower than in controls; the thickness of the media of small pulmonary arteries from LH + B lambs was similar to that in LH lambs and thicker than in controls. VEGF mRNA levels were not different between groups. PDGF mRNA levels in LH + B lambs were higher than in LH lambs; a similar trend (P = 0.06) was seen for PECAM-1. SP-C mRNA levels were greater in both LH and LH + B lambs than in controls. Effects of betamethasone were greater on indices of pulmonary circulation than ventilation. We conclude that a single dose of maternal betamethasone 24 hr prior to birth has significant favorable effects on the postnatal adaptation of the pulmonary circulation in lambs with LH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technical reliability (i.e., interinstrument and interoperator reliability) of three SEAC-swept frequency bioimpedance monitors was assessed for both errors of measurement and associated analyses. In addition, intraoperator and intrainstrument variability was evaluated for repeat measures over a 4-hour period. The measured impedance values from a range of resistance-capacitance circuits were accurate to within 3% of theoretical values over a range of 50-800 ohms. Similarly, phase was measured over the range 1 degrees-19 degrees with a maximum deviation of 1.3 degrees from the theoretical value. The extrapolated impedance at zero frequency was equally well determined (+/-3%). However, the accuracy of the extrapolated value at infinite frequency was decreased, particularly at impedances below 50 ohms (approaching the lower limit of the measurement range of the instrument). The interinstrument/operator variation for whole body measurements were recorded on human volunteers with biases of less than +/-1% for measured impedance values and less than 3% for phase. The variation in the extrapolated values of impedance at zero and infinite frequencies included variations due to operator choice of the analysis parameters but was still less than +/-0.5%. (C) 1997 Wiley-Liss, Inc.