55 resultados para EVOKED OTOACOUSTIC EMISSIONS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study examined effects of ear asymmetry, handedness, and gender on distortion-product otoacoustic emissions (DPOAEs) obtained from schoolchildren. A total of 1003 children (528 boys and 475 girls), with a mean age of 6.2 years (SD = 0.4, range = 5.2-7.9 years), were tested in a quiet room at their schools using the GSI-60 DPOAE system. A distortion-product (DP)-gram was obtained for each ear, with f2 varying from 1.1 to 6.0 kHz and the ratio of f2/f1 at 1.21. The signal-to-noise ratios (SNRs) (DPOAE amplitude minus the mean noise floor) at the tested frequencies 1.1, 1.5, 1.9, 2.4, 3.0, 3.8, 4.8, and 6.0 kHz were measured. The results revealed a small but significant difference in SNR between ears, with right ears showing a higher mean SNR than left ears at 1.9, 3.0, 3.8, and 6.0 kHz. At these frequencies, the difference in mean SNR between ears was less than 1 dB. A significant gender effect was also found. Girls exhibited a higher SNR than boys at 3.8, 4.8, and 6.0 kHz. The difference in mean SNR, as a result of the gender effect, was about 1 to 2 dB at these frequencies. There was no significant difference in mean SNR between left-handed and right-handed children for all tested frequencies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examined the test performance of distortion product otoacoustic emissions (DPOAEs) when used as a screening tool in the school setting. A total of 1003 children (mean age 6.2 years, SD = 0.4) were tested with pure-tone screening, tympanometry, and DPOAE assessment. Optimal DPOAE test performance was determined in comparison with pure-tone screening results using clinical decision analysis. The results showed hit rates of 0.86, 0.89, and 0.90, and false alarm rates of 0.52, 0.19, and 0.22 for criterion signal-to-noise ratio (SNR) values of 4, 5, and 11 dB at 1.1, 1.9, and 3.8 kHz respectively. DPOAE test performance was compromised at 1.1 kHz. In view of the different test performance characteristics across the frequencies, the use of a fixed SNR as a pass criterion for all frequencies in DPOAE assessments is not recommended. When compared to pure tone plus tympanometry results, the DPOAEs showed deterioration in test performance, suggesting that the use of DPOAEs alone might miss children with subtle middle ear dysfunction. However, when the results of a test protocol, which incorporates both DPOAEs and tympanometry, were used in comparison with the gold standard of pure-tone screening plus tympanometry, test performance was enhanced. In view of its high performance, the use of a protocol that includes both DPOAEs and tympanometry holds promise as a useful tool in the hearing screening of schoolchildren, including difficult-to-test children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to compare transient evoked otoacoustic emission (TEOAE) screening outcomes (pass/fail) across the seasons (spring, autumn, and winter) between infants and schoolchildren. A total of 526 infants (275 boys, 251 girls) with a mean age of 2.0 months (SD = 0.38 months) and 975 schoolchildren (513 boys, 462 girls) with a mean age of 6.2 years (SD = 0.36 years) were screened using the ILO Otodynamics Quickscreen program. The same TEOAE pass/fail criterion was applied to the two groups. The results indicated a significant difference in pass rates between infants (91.2% of 1052 ears) and schoolchildren (86.0% of 1950 ears). A seasonal effect was found only for schoolchildren, with a significantly lower pass rate in winter than in spring or autumn. There was no difference in pass rates between spring and autumn. Implications for the seasonal effect on TEOAE screening outcomes for infants and schoolchildren are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accurate interpretation of distortion product otoacoustic emission (DPOAE) data cannot be made without realizing the effects of non-pathological factors on DPOAEs. The present study aimed to examine the effects of ear asymmetry, gender and handedness on DPOAEs obtained from school children. One thousand and three children (528 boys and 475 girls) with a mean age of 6.2 years (SD = 0.4, range = 5.2 7.9 years) were tested in a quiet room at their schools using the GSI-60 DPOAE system. The stimuli consisted of two pure tones of different frequencies f1 and f2 presented at 65 and 55dB SPL respectively. A DP-gram was obtained for each ear with f2 varying from 1.1 to 6.0 kHz and the ratio of f2/f1 being kept at 1.21. The signal-to-noise ratios (SNR) (DPOAE amplitude minus the mean noise floor) at the tested frequencies 1.1, 1.5, 1.9, 2.4, 3.0, 3.8, 4.8, and 6.0 kHz were measured. The results revealed a small, but significant difference in SNR between ears, with right ears showing a higher mean SNR than left ears at 1.9, 3.0, 3.8 and 6.0 kHz. At these frequencies, the difference in mean SNR between ears was less than 1 dB. A significant gender effect was also found, with girls exhibiting a higher SNR than boys at 3.8, 4.8 and 6.0 kHz. The difference in mean SNR, as a result of the gender effect, was about 1 to 2 dB at these frequencies. The results from the present study indicated no significant difference in mean SNR between left-handed and right-handed children for all tested frequencies. In conclusion, these non-pathological characteristics of DPOAEs should be considered in the interpretation of DPOAE results for school children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The characteristics of high frequency (1000 Hz) acoustic admittance results obtained from normal neonates were described in this study. Participants were 170 healthy neonates (96 boys and 74 girls) aged between 1 and 6 days (mean = 3.26 days, SD = 0.92). Transient evoked otoacoustic emissions (TEOAEs), and 226 Hz and 1000 Hz probe tone tympanograms were obtained from the participants using a Madsen Capella OAE/middle ear analyser. The results showed that of the 170 neonates, 34 were not successfully tested in both ears, 14 failed the TEOAE screen in one or both ears, and 122 (70 boys, 52 girls) passed the TEOAE screen in both ears and also maintained an acceptable probe seal during tympanometry. The 1000 Hz tympanometric data for the 122 neonates (244 ears) showed a single-peaked tympanogram in 225 ears (92.2 %), a flat-sloping tympanogram in 14 ears (5.7 %), a double-peaked tympanogram in 3 ears (1.2 %) and other unusual shapes in 2 ears (0.8 %). There was a significant ear effect, with right ears showing significantly higher mean peak compensated static admittance and tympanometric width, but lower mean acoustic admittance at +200 daPa and gradient than left ears. No significant gender effects or its interaction with ear were found. The normative tympanometric data derived from this cohort may serve as a guide for detecting middle ear dysfunction in neonates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to investigate the effect of high-pass filtering on TEOAE obtained from 2-month-old infants as a function of filter cut-off frequency, activity states and pass/fail status of infants. Two experiments were performed. In Experiment 1, 100 2-month-old infants (200 ears) in five activity states (asleep, awake but peaceful, sucking a pacifier, feeding, restless) were tested by use of TEOAE technology. Five different filter conditions were applied to the TEOAE responses post hoc. The filter conditions were set at 781 Hz (default setting), 1.0, 1.2, 1.4 and 1.6 kHz. Results from this experiment showed that TEOAE parameters, such as whole-wave reproducibility (WR) and signal-to-noise ratio (SNR) at 0.8 kHz and 1.6 kHz, changed as a function of the cut-off frequency. The findings suggest that the 1.6 kHz and 1.2 kHz filter conditions are optimal for WR and SNR pass/fail criteria, respectively. Although all infant recordings appeared to benefit from the filtering, infants in the noisy states seemed to benefit the most. In Experiment 2, the high-pass filtering technique was applied to 23 infants (35 ears) who apparently failed the TEOAE tests on initial screening but were subsequently awarded a pass status based on the results from a follow-up auditory brainstem response (ABR) assessment. The findings showed a significant decrease in noise contamination of the TEOAE with a corresponding significant increase in WR. With high-pass filtering at 1.6 kHz, 21/35 ears could be reclassified into the pass category.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The early effects of clinical dose of cisplatin (100 mg/m(2)) on distort ion-product otoacoustic emissions (DPOAE) thresholds and the relationship between DPOAE threshold shifts and changes in plasma concentrations of filterable and total platinum (Pt) following infusion of cisplatin in a dog model were investigated. The DPOAE thresholds (based on input-output function) were measured 2 days before a single high dose of cisplatin administration, and compared with measurements recorded 2 and 4 days after infusion. The results revealed DPOAE thresholds to be elevated by 4 days after the administration of cisplatin. However, this elevation could not be correlated with plasma concentrations of filterable and total Pt, which showed little variation over the 48-hour postinfusion period between animals. The present study demonstrated that DPOAE thresholds have the potential to be used as an indicator of cisplatin-induced ototoxicity, and cisplatin-induced ototoxicity could not be explained by plasma Pt kinetics in individual animals.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Otoacoustic emissions are frequently acquired from patients in a variety of body positions aside from the standard, seated orientation. Yet little knowledge is available regarding whether these deviations will produce nonpathological changes to the clinical results obtained. The present study aimed to describe the effects of body position on the distortion-product otoacoustic emissions of 60 normal-hearing adults. With particular attention given to common clinical practice, the Otodynamics ILO292, and the measurement parameters of amplitude, signal-to-noise ratio, and noise were utilized. Significant position-related effects and interactions were revealed for all parameters. Specifically, stronger emissions in the mid frequencies and higher noise levels at the extreme low and high frequencies were produced by testing subjects while lying on their side compared with the seated position. Further analysis of body position effects on emissions is warranted, in order to determine the need for clinical application of position-dependent normative data.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Despite widespread awareness that children with Down syndrome are particularly susceptible to hearing pathologies, the audiological status of students with Down syndrome in special schools is all too often unknown. Unfortunately, hearing screening for this population is unable to rely on standard, behavioural test batteries. To facilitate future improvements in screening protocols, this study investigated the results of tympanometry and transient evoked otoacoustic emission (TEOAE) testing for a group of children with Down syndrome. Assessments were not conducted in the artificial context of a clinic or laboratory, but within the school environment. Outcomes are reported for 27 subjects with a mean age of 10 years 5 months (SD = 4;11). Tympanometry testing was failed in at least one ear by 41.7% of subjects, while a failure rate of 81.5% of subjects was observed for TEOAE testing. Therefore, it is concluded that immediate review of hearing screening programs for students with Down syndrome is highly advisable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a study of merger-evoked cultural change in three organizations, quantitative and qualitative data were collected from individuals at all employment levels in both merger partners within each organization. Results were that most individuals perceived that the merger had impacted significantly on them personally. There was, however, a perceived lack of congruence between the organizational cultures of merging partners, resulting in cultural clashes and significant changes to the organizations' organizational cultures. More specifically, outcomes for both individuals and the subsequent acculturation following the mergers were related to the approach adopted to manage the merger process: incremental, immediate, or indifferent.