35 resultados para Digital Earth


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship between the ordering characteristic of the pyrochlore structure type and that characteristic of the defect fluorite structure type (immediately on either side of two phase regions separating the two structure types) in a range of rare eath sesquioxide stabilized cubic zirconias is investigated via electron diffraction and imaging. Systematic structural change as a function of composition and relative size of the constituent metal ions is highlighted and a multi-q to single-q = 1/2 [111]* model proposed for the observed pyrochlore to defect fluorite phase transition. Strain introduced into the close-packed {111} metal ion planes of the defect fluorite average structure by the local cation and oxygen vacancy distribution is pointed to as the likely origin of the observed behavior. (C) 2001 Academic Press

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are many methods for the analysis and design of embedded cantilever retaining walls. They involve various different simplifications of the pressure distribution to allow calculation of the limiting equilibrium retained height and the bending moment when the retained height is less than the limiting equilibrium value, i.e. the serviceability case. Recently, a new method for determining the serviceability earth pressure and bending moment has been proposed. This method makes an assumption defining the point of zero net pressure. This assumption implies that the passive pressure is not fully mobilised immediately below the excavation level. The finite element analyses presented in this paper examine the net pressure distribution on walls in which the retained height is less, than the limiting equilibrium value. The study shows that for all practical walls, the earth pressure distributions on the front and back of the wall are at their limit values, Kp and K-a respectively, when the lumped factor of safety F-r is less than or equal to2.0. A rectilinear net pressure distribution is proposed that is intuitively logical. It produces good predictions of the complete bending moment diagram for walls in the service configuration and the proposed method gives results that have excellent agreement with centrifuge model tests. The study shows that the method for determining the serviceability bending moment suggested by Padfield and Mair(1) in the CIRIA Report 104 gives excellent predictions of the maximum bending moment in practical cantilever walls. It provides the missing data that have been needed to verify and justify the CIRIA 104 method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective-To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients. Design-Cohort study. Setting-Regional cardiothoracic unit. Patients-49 patients (mean (SD) age 61 (11) years; 27 women, 22 men) with known or suspected coronary artery disease were studied with simultaneous myocardial contrast echo (MCE) and SPECT after standard dipyridamole stress. Main outcome measures-Regional myocardial perfusion by SPECT, performed with Tc-99m tetrafosmin, scored qualitatively and also quantitated as per cent maximum activity. Results-Normal perfusion was identified by SPECT in 225 of 270 segments (83%). Contrast echo images were interpretable in 92% of patients. The proportion of normal MCE by grey scale, subtracted, and power Doppler techniques were respectively 76%, 74%, and 88% (p < 0.05) at > 80% of maximum counts, compared with 65%, 69%, and 61% at < 60% of maximum counts. For each technique, specificity was lowest in the lateral wail, although power Doppler was the least affected. Grey scale and subtraction techniques were least accurate in the septal wall, but power Doppler showed particular problems in the apex. On a per patient analysis, the sensitivity was 67%, 75%, and 83% for detection of coronary artery disease using grey scale, colour coded, and power Doppler, respectively, with a significant difference between power Doppler and grey scale only (p < 0.05). Specificity was also the highest for power Doppler, at 55%, but not significantly different from subtracted colour coded images. Conclusions-Myocardial contrast echo using harmonic power Doppler has greater accuracy than with grey scale imaging and digital subtraction. However, power Doppler appears to be less sensitive for mild perfusion defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Although digital and videotaped images are known to be comparable for the evaluation of left ventricular function, their relative accuracy for assessment of more complex anatomy is unclear. We sought to compare reading time, storage costs, and concordance of video and digital interpretations across multiple observers and sites. Methods. One hundred one patients with valvular (90 mitral, 48 aortic, 80 tricuspid) disease were selected prospectively, and studies were stored according to video and standardized digital protocols. The same reviewer interpreted video and digital images independently and at different times with the use of a standard report form to evaluate 40 items (eg, severity of stenosis or regurgitation, leaflet thickening, and calcification) as normal or mildly, moderately, or severely abnormal Concordance between modalities was expressed at kappa Major discordance (difference of >1 level of severity) was ascribed to the modality that gave the lesser severity. CD-ROM was used to store digital data (20:1 lossy compression), and super-VHS video-tape was used to store video data The reading time and storage costs for each modality were compared Results. Measured parameters were highly concordant (ejection fraction was 52% +/- 13% by both). Major discordance was rare, and lesser values were reported with digital rather than video interpretation in the categories of aortic and mitral valve thicken ing (1% to 2%) and severity of mitral regurgitation (2%). Digital reading time was 6.8 +/- 2.4 minutes, 38% shorter than with video (11.0 +/- 3.0, range 8 to 22 minutes, P < .001). Compressed digital studies had an average size of 60 <plus/minus> 14 megabytes (range 26 to 96 megabytes). Storage cost for video was A$0.62 per patient (18 studies per tape, total cost A$11.20), compared with A$0.31 per patient for digital storage (8 studies per CD-ROM, total cost A$2.50). Conclusion. Digital and video interpretation were highly concordant; in the few cases of major discordance, the digital scores were lower, perhaps reflecting undersampling. Use of additional views and longer clips may be indicated to minimize discordance with video in patients with complex problems. Digital interpretation offers a significant reduction in reading times and the cost of archiving.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Challenges posed to copyright law in the digital age is most evident in A and M Records Inc v Napster Inc - the various court rulings indicate that Napster is likely to be held responsible for massive copyright infringement should the case come to a full trial - implications for Australian copyright law, the recording industry and individual artists - globalisation may hinder the ability of the recording industry to prevent mass copyright infringement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

If the Internet could be used as a method of transmitting ultrasound images taken in the field quickly and effectively, it would bring tertiary consultation to even extremely remote centres. The aim of the study was to evaluate the maximum degree of compression of fetal ultrasound video-recordings that would not compromise signal quality. A digital fetal ultrasound videorecording of 90 s was produced, resulting in a file size of 512 MByte. The file was compressed to 2, 5 and 10 MByte. The recordings were viewed by a panel of four experienced observers who were blinded to the compression ratio used. Using a simple seven-point scoring system, the observers rated the quality of the clip on 17 items. The maximum compression ratio that was considered clinically acceptable was found to be 1:50-1:100. This produced final file sizes of 5-10 MByte, corresponding to a screen size of 320 x 240 pixels, running at 15 frames/s. This study expands the possibilities for providing tertiary perinatal services to the wider community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The growth of direct marketing has been attributed to rapid advances in technology and the changing market context. The fundamental ability of direct marketers to communicate with consumers and to elicit a response, combined with the ubiquitous nature and power of mobile digital technology, provides a synergy that will increase the potential for the success of direct marketing. The aim of this paper is to provide an analytical framework identifying the developments in the digital environment from e-marketing to m-marketing, and to alert direct marketers to the enhanced capabilities available to them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of my action research. I was involved in establishing and running a digital library that was founded by the government of South Korea. The process involved understanding the relationship between the national IT infrastructure and the success factors of the digital library. In building, the national IT infrastructure, a digital library system was implemented; it combines all existing digitized university libraries and can provide overseas information, such as foreign journal articles, instantly and freely to every Korean researcher. An empirical survey was made as a part of the action research; the survey determined user satisfaction in the newly established national digital library. After obtaining the survey results, I suggested that the current way of running the nationwide government-owned digital library should be retained. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 'Late Heavy Bombardment' was a phase in the impact history of the Moon that occurred 3.8-4.0 Gyr ago, when the lunar basins with known dates were formed(1,2). But no record of this event has yet been reported from the few surviving rocks of this age on the Earth. Here we report tungsten isotope anomalies, based on the Hf-182-W-182 system (half-life of 9 Myr), in metamorphosed sedimentary rocks from the 3.7-3.8-Gyr-old Isua greenstone belt of West Greenland and closely related rocks from northern Labrador, Canada. As it is difficult to conceive of a mechanism by which tungsten isotope heterogeneities could have been preserved in the Earth's dynamic crust-mantle environment from a time when short-lived Hf-182 was still present, we conclude that the metamorphosed sediments contain a component derived from meteorites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present whole-rock and zircon rare earth element (REE) data from two early Archaean gneisses (3.81 Ga and 3.64 Ga) from the Itsaq gneiss complex, south-west Greenland. Both gneisses represent extremely rare examples of unaltered, fresh and relatively undeformed igneous rocks of such antiquity. Cathodoluminescence imaging of their zircons indicates a single crystallisation episode with no evidence for either later metamorphic and/or anatectic reworking or inheritance of earlier grains. Uniform, single-population U/Pb age data confirm the structural simplicity of these zircons. One sample, a 3.64 Ga granodioritic gneiss from the Gothabsfjord, yields a chondrite-normalised REE pattern with a positive slope from La to Lu as well as substantial positive Ce and slight negative Eu anomalies, features generally considered to be typical of igneous zircon. In contrast, the second sample, a 3.81 Ga tonalite from south of the Isua Greenstone Belt, has variable but generally much higher light REE abundances, with similar middle to heavy REE. Calculation of zircon/melt distribution coefficients (D-REE(zircon/melt)) from each sample yields markedly different values for the trivalent REE (i.e. Ce and Eu omitted) and simple application of one set of D-REE(zircon/melt) to model the melt composition for the other sample yields concentrations that are in error by up to two orders of magnitude for the light REE (La-Nd). The observed light REE overabundance in the 3.81 Ga tonalite is a commonly observed feature in terrestrial zircons for which a number of explanations ranging from lattice strain to disequilibrium crystallisation have been proposed and are further investigated herein. Regardless of the cause of light REE overabundance, our study shows that simple application of zircon/melt distribution coefficients is not an unambiguous method for ascertaining original melt composition. In this context, recent studies that use REE data to claim that > 4.3 Ga Hadean detrital zircons originally crystallised from an evolved magma, in turn suggesting the operation of geological processes in the early Earth analogous to those of the present day (e.g. subduction and melting of hydrated oceanic crust), must be regarded with caution. Indeed, comparison of terrestrial Hadean and > 3.9 Ga lunar highland zircons shows remarkable similarities in the light REE, even though subduction processes that have been used to explain the terrestrial zircons have never operated on the Moon. (C) 2002 Elsevier Science B.V. All rights reserved.