66 resultados para Blood Pumps


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents cost-effectiveness analyses (CEAs) of plasma collection via two alternative methods: whole blood collection (WBC) and erythroplasmapheresis collection (EPC). The objective of the study is to provide an answer to the question 'What is the least-cost method of plasma production'. This question is answered, both from the viewpoint of the blood collection agency (using financial CEA) and from that of 'society' as a whole (using economic CEA). We employ detailed financial data and economic survey data for collections made by a blood collection agency and to WBC and EPC donors in Brisbane, Australia. The results indicate that, despite the superior yield provided by EPC, WBC is actually more cost-effective. This result is robust to thorough sensitivity analysis and arises regardless of whether an economic or financial perspective is taken. We conclude that, ceteris paribus, the cost of recruiting new plasma donors would need to be quite substantial for marginal investments in EPC to be considered cost-effective. Crown Copyright (C) 2002 Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spray-dried blood plasma (DBP) (10.9 g/100 g [w/w] nitrogen) was added to medium-protein biscuit flour (1.4 g/100 g N) during pasta manufacture. High-protein durum semolina (2.0 g/100 g N) Was used to produce the control pasta. Sensory data indicated that the addition of DBP produced pasta with significantly better colour intensity and acceptability. aroma intensity, flaN our intensity. textural strength, texture acceptability, aftertaste intensity, aftertaste acceptability. and overall acceptability The DBP/biscuit flour formulation that gave the optimum balance between pasta protein content and organoleptic acceptability contained 2.2 g/100 g DBP. A higher content of DBP resulted in increased protein levels, but these pasta formulations, ere less acceptable organoleptically. (C) 2002 Swiss Society of Food Science and Technology. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positive end expiratory pressure (PEEP) is important for neonatal ventilation but is not considered in guidelines for resuscitation. Our aim was to investigate the effects of PEEP on cardiorespiratory parameters during resuscitation of very premature lambs delivered by hysterotomy at similar to125 d gestation (term similar to147 d). Before delivery, they were intubated and lung fluid was drained. Immediately after delivery, they were ventilated with a Drager Babylog plus ventilator in volume guarantee mode with a tidal volume of 5 mL/kg. Lambs were randomized to receive 0, 4, 8, or 12 cm H2O of PEEP. They were ventilated for a 15-min resuscitation period followed by 2 h of stabilization at the same PEEP. Tidal volume, peak inspiratory pressure, PEEP, arterial pressure, oxygen saturation, and blood gases were measured regularly, and respiratory system compliance and alveolar/ arterial oxygen differences were calculated. Lambs that received 12 cm H2O of PEEP died from pneumothoraces; all others survived without pneumothoraces. Oxygenation was significantly improved by 8 and 12 cm H2O of PEEP compared with 0 and 4 cm H2O of PEEP. Lambs with 0 PEEP did not oxygenate adequately. The compliance of the respiratory system was significantly higher at 4 and 8 cm H2O of PEEP than at 0 PEEP. There were no significant differences in partial pressure of carbon dioxide in arterial blood between groups. Arterial pressure was highest with 8 cm H2O of PEEP, and there was no cardiorespiratory compromise at any level of PEEP. Applying PEEP during resuscitation of very premature infants might be advantageous and merits further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose - Epidemiological and laboratory studies suggest that increasing concentrations of plasma homocysteine ( total homocysteine [tHcy]) accelerate cardiovascular disease by promoting vascular inflammation, endothelial dysfunction, and hypercoagulability. Methods - We conducted a randomized controlled trial in 285 patients with recent transient ischemic attack or stroke to examine the effect of lowering tHcy with folic acid 2 mg, vitamin B-12 0.5 mg, and vitamin B-6 25 mg compared with placebo on laboratory markers of vascular inflammation, endothelial dysfunction, and hypercoagulability. Results - At 6 months after randomization, there was no significant difference in blood concentrations of markers of vascular inflammation (high-sensitivity C-reactive protein [P = 0.32]; soluble CD40L [ P = 0.33]; IL-6 [P = 0.77]), endothelial dysfunction ( vascular cell adhesion molecule-1 [P = 0.27]; intercellular adhesion molecule-1 [P = 0.08]; von Willebrand factor [P = 0.92]), and hypercoagulability (P-selectin [P = 0.33]; prothrombin fragment 1 and 2 [P = 0.81]; D-dimer [P = 0.88]) among patients assigned vitamin therapy compared with placebo despite a 3.7-mumol/L (95% CI, 2.7 to 4.7) reduction in total homocysteine (tHcy). Conclusions - Lowering tHcy by 3.7 mumol/L with folic acid-based multivitamin therapy does not significantly reduce blood concentrations of the biomarkers of inflammation, endothelial dysfunction, or hypercoagulability measured in our study. The possible explanations for our findings are: ( 1) these biomarkers are not sensitive to the effects of lowering tHcy (eg, multiple risk factor interventions may be required); ( 2) elevated tHcy causes cardiovascular disease by mechanisms other than the biomarkers measured; or ( 3) elevated tHcy is a noncausal marker of increased vascular risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to prospectively investigate the peak levels and kinetics of donor leucocyte chimerism in human recipients following liver transplantation, The peak levels of chimerism mere observed within the first 48 hours following transplantation and ranged from 0.15% to 20% of total peripheral blood mononuclear cells, In all but one patient, who developed graft versus host disease, there was an early peak level of chimerism that declined over time such that donor leukocytes mere only intermittently detectable after 3 to 4 weeks. In 8 patients who had no episodes of graft rejection, the peak level of donor leukocyte chimerism ranged from 1.3% to 20% (mean +/- SEM; 5.5% +/- 2.1%). In 3 patients who were treated for episodes of acute graft rejection during the first four postoperative weeks, the peak level of donor leukocyte chimerism ranged from 0.15% to 0.2% (0.18 +/- 0.02, P = .012), The results demonstrate a marked variation in the total number of donor leukocytes detectable in the peripheral blood early after liver transplantation and also, that lower levels of chimerism may be associated with lower rates of initial graft acceptance and a higher incidence of acute rejection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cell-surface proteoglycans are involved in lymphocyte migration and activation. This study investigated the expression of syndecan-1, syndecan-4, and glypican in peripheral blood lymphocytes and by lymphocytes in variously inflamed periodontal tissues. Gingival specimens from healthy, gingivitis, or chronic periodontitis sites were stained by means of antibodies against B- and T-lymphocytes and also syndecan-1, syndecan-4, and glypican. Syndecan-1 expression by peripheral blood mononuclear cells (PBMC) from healthy, gingivitis, and chronic periodontitis subjects was assessed by flow cytometry. Syndecan-1 was expressed by B-cells/plasma cells but not T-cells in both gingivitis and chronic periodontitis lesions, Both B-cells/plasma cells and T-cells in gingivitis and chronic periodontitis expressed syndecan-4. Glypican was expressed only by macrophages. Stimulation of PBMC with mitogens and growth factors modulated syndecan-1 expression in both the T- and B-cells. Thus, cell-surface proteoglycan expression by lymphocytes in periodontal inflammation is cell-type-specific and may be modulated by inflammation.