27 resultados para Automatic frequency control


Relevância:

30.00% 30.00%

Publicador:

Resumo:

As survival of patients with CF increases,glucose intolerance and cystic fibrosisrelated diabetes (CFRD),ar e increasingly recognised common complications. CFRD may be preceded by a pre-diabetic state. Using markers identified as being associated with CFRD may improve targeted screening. Aim: To identify features consistently predicting CFRD in paediatric patients. Patients diagnosed with CFRD between January 1997–January 2002 were compared with age and sex matched controls. Clinical,micr obiological, and hospitalisation data was collected at time of CFRD diagnosis,and at six monthly intervals for 3 yr prior to diagnosis. Eight patients with CFRD were identified,mean age 13.7 yr (S.D. 3.49) at time of diagnosis. Control patients underwent OGTT to ensure normal glucose tolerance. Patients with CFRD had a lower FEV1 up to 12 months prior to diagnosis however, this was only significant at diagnosis. There was no difference in weight and height z scores between the 2 groups; however,the decrease in weight and height z scores in the CFRD group over 3 yr prior to diagnosis was significant. Mean number of days in hospital and admissions per patient significantly increased in the CFRD group,6 months prior to diagnosis. No other significant differences were observed between the 2 groups. Conclusions: This study has shown a difference in lung function,gr owth parameters and frequency of hospital admissions between patients with CFRD and controls. These differences may be utilised as tools for targeted screening in the paediatricyadolescent population. Further larger scale studies are required to improve guidelines for targeted screening in this population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For dynamic closed loop control of a multilevel converter with a low pulse number (ratio of switching frequency to synthesized fundamental), natural sampled pulse-width modulation (PWM) is the best form of modulation. Natural sampling does not introduce distortion or a delayed response to the modulating signal. However previous natural sampled PWM implementations have generally been analog. For a modular multilevel converter, a digital implementation has advantages of accuracy and flexibility. Re-sampled uniform PWM is a novel digital modulation technique which approaches the performance of natural PWM. Both hardware and software implementations for a five level multilevel converter phase are presented, demonstrating the improvement over uniform PWM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The impact of basal ganglia dysfunction on semantic processing was investigated by comparing the performance of individuals with nonthalamic subcortical (NS) vascular lesions, Parkinson's disease (PD), cortical lesions, and matched controls on a semantic priming task. Unequibiased lexical ambiguity primes were used in auditory prime-target pairs comprising 4 critical conditions; dominant related (e.g., bank-money), subordinate related (e.g., bank-river), dominant unrelated (e.g.,foot-money) and subordinate unrelated (e.g., bat-river). Participants made speeded lexical decisions (word/nonword) on targets using a go-no-go response. When a short prime-target interstimulus interval (ISI) of 200 ins was employed, all groups demonstrated priming for dominant and subordinate conditions, indicating nonselective meaning facilitation and intact automatic lexical processing. Differences emerged at the long ISI (1250 ms), where control and cortical lesion participants evidenced selective facilitation of the dominant meaning, whereas NS and PD groups demonstrated a protracted period of nonselective meaning facilitation. This finding suggests a circumscribed deficit in the selective attentional engagement of the semantic network on the basis of meaning frequency, possibly implicating a disturbance of frontal-subcortical systems influencing inhibitory semantic mechanisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The calcium-dependent afterhyperpolarization (AHP) that follows trains of action potentials is responsible for controlling action potential firing patterns in many neuronal cell types. We have previously shown that the slow AHP contributes to spike frequency adaptation in pyramidal neurons in the rat lateral amygdala. In addition, a dendritic voltage-gated potassium current mediated by Kv1.2-containing channels also suppresses action potential firing in these neurons. In this paper we show that this voltage-gated potassium current and the slow AHP act together to control spike frequency adaptation in lateral amygdala pyramidal neurons. The two currents have similar effects on action potential number when firing is evoked either by depolarizing current injections or by synaptic stimulation. However, they differ in their control of firing frequency, with the voltage-gated potassium current but not the slow AHP determining the initial frequency of action potential firing. This dual mechanism of controlling firing patterns is unique to lateral amygdala neurons and is likely to contribute to the very low levels of firing seen in lateral amygdala neurons in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Solutions employing perturbation stiffness or viscous hourglass control with one-point quadrature finite elements often exhibit spurious modes in the intermediate frequency range. These spurious frequencies are demonstrated in several examples and their origin is explained. Then it is shown that by critically damping the hourglass modes, these spurious mid-range frequency modes can be suppressed. Estimates of the hourglass frequency and damping coefficients are provided for the plane 4-node quadrilateral and a 4-node shell element. Results are presented that show almost complete annihilation of spurious intermediate frequency modes for both linear and non-linear problems. Copyright (c) 2005 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. Evidence exists for an association between migraine and ischaemic stroke, but there is uncertainty about whether migraine is a risk factor for subarachnoid haemorrhage (SAH). Methods. A multi-centre, population-based, case-control study using cases of first-ever SAH during 1995-98 and matched controls in four study centres in Australia and New Zealand. Self- or proxy-reported history, frequency and characteristics of headaches, classified according to 1988 International Headache Society diagnostic criteria. Results. 206 of 432 (48%) cases and 236 of 473 (50%) controls had a history of headaches. The frequency and characteristics of headaches were similar between the two groups. No association was found in logistic regression analyses for history or frequency of headaches, or migraine headaches. Conclusions. No evidence was found for an association between recurrent headaches and SAH. Such information is important for counselling patients and families about the significance of past and ongoing headaches in relation to this illness. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The characterization of blood pressure in treatment trials assessing the benefits of blood pressure lowering regimens is a critical factor for the appropriate interpretation of study results. With numerous operators involved in the measurement of blood pressure in many thousands of patients being screened for entry into clinical trials, it is essential that operators follow pre-defined measurement protocols involving multiple measurements and standardized techniques. Blood pressure measurement protocols have been developed by international societies and emphasize the importance of appropriate choice of cuff size, identification of Korotkoff sounds, and digit preference. Training of operators and auditing of blood pressure measurement may assist in reducing the operator-related errors in measurement. This paper describes the quality control activities adopted for the screening stage of the 2nd Australian National Blood Pressure Study (ANBP2). ANBP2 is cardiovascular outcome trial of the treatment of hypertension in the elderly that was conducted entirely in general practices in Australia. A total of 54 288 subjects were screened; 3688 previously untreated subjects were identified as having blood pressure >140/90 mmHg at the initial screening visit, 898 (24%) were not eligible for study entry after two further visits due to the elevated reading not being sustained. For both systolic and diastolic blood pressure recording, observed digit preference fell within 7 percentage points of the expected frequency. Protocol adherence, in terms of the required minimum blood pressure difference between the last two successive recordings, was 99.8%. These data suggest that adherence to blood pressure recording protocols and elimination of digit preferences can be achieved through appropriate training programs and quality control activities in large multi-centre community-based trials in general practice. Repeated blood pressure measurement prior to initial diagnosis and study entry is essential to appropriately characterize hypertension in these elderly patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients with low back pain (LBP) often present with impaired proprioception of the lumbopelvic region. For this reason, proprioception training usually forms part of the rehabilitation protocols. New exercise equipment that produces whole body, low frequency vibration (WBV) has been developed to improve muscle function, and reportedly improves proprioception. The aim of this pilot study was to investigate whether weightbearing exercise given in conjunction with WBV would affect lumbosacral position sense in healthy individuals. For this purpose, twenty-five young individuals with no LBP were assigned randomly to an experimental or control group. The experimental group received WBV for five minutes while holding a static, semi-squat position. The control group adopted the same weightbearing position for equal time but received no vibration. A two-dimensional motion analysis system measured the repositioning accuracy of pelvic tilting in standing. The experimental (WBV) group demonstrated a significant improvement in repositioning accuracy over time (mean 0.78 degrees) representing 39% improvement. It was concluded that WBV may induce improvements in lumbosacral repositioning accuracy when combined with a weightbearing exercise. Future studies with WBV should focus on evaluating its effects with different types of exercise, the exercise time needed for optimal outcomes, and the effects on proprioception deficits in LBP patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Voluntary limb movements are associated with involuntary and automatic postural adjustments of the trunk muscles. These postural adjustments occur prior to movement and prevent unwanted perturbation of the trunk. In low back pain, postural adjustments of the trunk muscles are altered such that the deep trunk muscles are consistently delayed and the superficial trunk muscles are sometimes augmented. This alteration of postural adjustments may reflect disruption of normal postural control imparted by reduced central nervous system resources available during pain, so-called pain interference, or reflect adoption of an alternate postural adjustment strategy. Methods: We aimed to clarify this by recording electromyographic activity of the upper (obliquus extemus) and lower (transversus abdominis/obliquus internus) abdominal muscles during voluntary arm movements that were coupled with painful cutaneous stimulation at the low back. If the effect of pain on postural adjustments is caused by pain interference, it should be greatest at the onset of the stimulus, should habituate with repeated exposure, and be absent immediately when the threat of pain is removed. Sixteen patients performed 30 forward movements of the right arm in response to a visual cue (control). Seventy trials were then conducted in which arm movement was coupled with pain (pain trials) and then a further 70 trials were conducted without the pain stimulus (no pain trials). Results: There was a gradual and increasing delay of transversus abdominis/obliquus internus electromyograph and augmentation of obliquus externus during the pain trials, both of which gradually returned to control values during the no pain trials. Conclusion: The results suggest that altered postural adjustments of the trunk muscles during pain are not caused by pain interference but are likely to reflect development and adoption of an alternate postural adjustment strategy, which may serve to limit the amplitude and velocity of trunk excursion caused by arm movement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bang-bang phase detector based PLLs are simple to design, suffer no systematic phase error, and can run at the highest speed a process can make a working flip-flop. For these reasons designers are employing them in the design of very high speed Clock Data Recovery (CDR) architectures. The major drawback of this class of PLL is the inherent jitter due to quantized phase and frequency corrections. Reducing loop gain can proportionally improve jitter performance, but also reduces locking time and pull-in range. This paper presents a novel PLL design that dynamically scales its gain in order to achieve fast lock times while improving fitter performance in lock. Under certain circumstances the design also demonstrates improved capture range. This paper also analyses the behaviour of a bang-bang type PLL when far from lock, and demonstrates that the pull-in range is proportional to the square root of the PLL loop gain.