34 resultados para Anesthesia, inhalation
Resumo:
This paper is a brief report of the symposium, Improving the Evidence Base for Anaesthesia and Intensive Care, organized by the MASTER Anaesthesia Trial Study Group at the Annual Scientific Meeting of the Australian and New Zealand College of Anaesthetists, Newcastle, N.S.W. on Tuesday, May 5, 1998.
Resumo:
Background Epidural block is widely used to manage major abdominal surgery and postoperative analgesia, but its risks. and benefits are uncertain. We compared adverse outcomes in high-risk patients managed for major surgery with epidural block or alternative analgesic regimens with general anaesthesia in a multicentre randomised trial. Methods 915 patients undergoing major abdominal surgery with one of nine defined comorbid states to identify high-risk status were randomly assigned intraoperative epidural anaesthesia and postoperative epidural analgesia for 72 h with general anaesthesia (site of epidural selected to provide optimum block) or control. The primary endpoint was death at 30 days or major postsurgical morbidity. Analysis by intention to treat involved 447 patients assigned epidural and 441 control. Findings 255 patients (57.1%) in the epidural group and 268 (60.7%) in the control group had at least one morbidity endpoint or died (p=0.29). Mortality at 30 days was low in both groups (epidural 23 [5.1%], control 19 [4.3%], p=0.67). Only one of eight categories of morbid endpoints in individual systems (respiratory failure) occurred less frequently in patients managed with epidural techniques (23% vs 30%, p=0.02). Postoperative epidural analgesia was associated with lower pain scores during the first 3 postoperative days. There were no major adverse consequences of epidural-catheter insertion. Interpretation Most adverse morbid outcomes in high-risk patients undergoing major abdominal surgery are not reduced by use of combined epidural and general anaesthesia and postoperative epidural analgesia. However, the improvement in analgesia, reduction in respiratory failure, and the low risk of serious adverse consequences suggest that many high-risk patients undergoing major intra-abdominal surgery will receive substantial benefit from combined general and epidural anaesthesia intraoperatively with continuing postoperative epidural analgesia.
Resumo:
In a primary analysis of a large recently completed randomized trial in 915 high-risk patients undergoing major abdominal surgery, we found no difference in outcome between patients receiving perioperative epidural analgesia and those receiving IV opioids, apart from the incidence of respiratory failure. Therefore, we performed a selected number of predetermined subgroup analyses to identify specific types of patients who may have derived benefit from epidural analgesia. We found no difference in outcome between epidural and control groups in subgroups at increased risk of respiratory or cardiac complications or undergoing aortic surgery, nor in a subgroup with failed epidural block (all P > 0.05). There was a small reduction in the duration of postoperative ventilation (geometric mean [SD]: control group, 0.3 [6.5] h, versus epidural group, 0.2 [4.8] h, P = 0.048). No differences were found in length of stay in intensive care or in the hospital. There was no relationship between frequency of use of epidural analgesia in routine practice outside the trial and benefit from epidural analgesia in the trial. We found no evidence that perioperative epidural analgesia significantly influences major morbidity or mortality after major abdominal surgery.
Resumo:
Three experiments explored the effectiveness of continuous auditory displays, or sonifications, for conveying information about a simulated anesthetized patient's respiration. Experiment 1 established an effective respiratory sonification. Experiment 2 showed an effect of expertise in the use of respiratory sonification and revealed that some apparent differences in sonification effectiveness could be accounted for by response bias. Experiment 3 showed that sonification helps anesthesiologists to maintain high levels of awareness of the simulated patient's state while performing other tasks more effectively than when relying upon visual monitoring of the simulated patient state. Overall, sonification of patient physiology beyond traditional pulse oximetry appears to be a viable and useful adjunct to visual monitors. Actual and potential applications of this research include monitoring in a wide variety of busy critical care contexts.
Resumo:
The prevalence of neoplasia in birds is generally low; however, in some species of companion and aviary birds, the incidence is high and neoplasia is a common cause of death. Surgical excision or limb amputation has been performed as the therapeutic plan. Chemotherapy in the treatment of avian neoplasia is largely empirical and poorly documented. For example, cisplatin has been used intralesionally in macaws (Ara species) with limited clinical success. Eight sulphur-crested cockatoos (Cacatua galerita), under general isoflurane anesthesia, were infused intravenously with cisplatin at 6.4 or 1.0 mg/kg over 1 hour and hydrated with lactated Ringer's solution for 1 hour before and 2 hours after cisplatin infusion. Birds were euthanatized 96 hours after infusion, except for 2 birds given the low cisplatin dose, which were euthanatized on day 35 after dosing. All birds tolerated the study procedure while under anesthesia. Blood pressure, heart rate, and respiratory rate did not change significantly. In the low-dose group, the mean cloacal temperature decreased significantly during the infusion period (P < .001) and then rose progressively to preinfusion values by 24 hours. Also in this group, the mean body weight tended to increase during the infusion period before significantly decreasing (P < .05) by 5% at 96 hours after dosing. At 24 hours after dosing, all birds were bright and eating. However, intermittent regurgitation and fecal changes (moist, dark green feces and yellow urates) occurred in 3 of 8 birds, especially those given the high dose. By 72 hours after dosing, droppings in the low-dose group were normal in appearance. One bird in the high-dose group died by 94 hours after dosing. Myelosuppression was not observed in any bird and at necropsy, no evidence of cisplatin toxicity was found except in 1 bird given the high cisplatin dose. On histology, this bird showed nephrotoxicity, and its serum uric acid levels and mean estimated white blood cell count increased significantly by 24 hours after dosing. This paper reports for the first time the effect of systemic cisplatin administration in birds and provides veterinarians data for formulating efficacious and safe protocols for platinum-containing compounds when treating neoplasia in parrots and other companion birds.
Resumo:
When visual information is confined to one object plane, the emmetropization end-point is adjusted in accord with the corresponding incident optical vergence at the eye [Proceedings of the 7th International Conference on Myopia (2000) 113]. We now report the effect of adding extra visual information beyond the target plane. Visual conditions were controlled using a cone-lens system: black Maltese cross targets on white opaque backgrounds (OMX) were attached to the open faces of 2.5 cm translucent cones fitted with either 0, +25 or +40 D imaging lenses. An alternative target (TMX) was made by substituting the opaque target background for a transparent background, which allowed access to visual information beyond the target plane. The imaging devices were applied to 7-day-old chicks and worn for 4 days. Prior to this treatment, on day 2, some chicks underwent ciliary nerve section (CNS) to preclude accommodation. All treatments were monocular. Refractive errors and axial ocular dimensions were measured using retinoscopy and A-scan ultrasonography under halothane anesthesia. Treatment effects were specified as mean ( +/-S.D.) interocular differences. Eyes with the OMX/ + 40 D lens combination remained emmetropic ( +0.73 +/-3.57 D), consistent with the target plane being approximately conjugate with the retina. Switching to the TMX caused a hyperopic shift in refractive error ( + 3.78 +/- 3.41 D). This relative shift towards hyperopia in switching from the OMX to the TMX target also occurred for the other two lens powers. Thus, the OMX/ + 25 D lens induced myopia ( - 7.00 +/-5.88 D), corresponding to the imposed hyperopic defocus (target plane now imaged behind the retina), and switching to the TMX resulted in a reduction in myopia (-1.73 +/-5.36 D), The OMX/0 D lens combination produced the largest myopic shift, and here, switching to the TMX condition almost eliminated the myopic response (-15.50 +/-6.62 D cf. -0.56 +/-1.24 D). This relative hyperopic shift associated with switching from the OMX to the TMX target was eliminated by CNS surgery. Thus, the two CNS/TMX groups were both more myopic than the equivalent no CNS/TMX groups ( + 40 D lens: -2.66 +/-2.34 D; +25 D lens: -7.97 +/-6.87 D). When the visual information is restricted to one plane, incident optical vergence appears to direct emmetropization. Adding Visual information at other distances produces a shift in the end-point of ernmetropization in the direction of the added information. That these effects are dependent on the integrity of the accommodation system implies that accommodation plays a role in emmetropization and represents the first reported evidence of this kind. Published by Elsevier Science Ltd.
Resumo:
Background: Burn care has changed considerably. Early surgery, nutritional support, improved resuscitation and novel skin replacement techniques are now well established. The aim of the study was to establish whether changes in management have improved survival following burn injury and to determine the contributory factors leading to non-survival. Methods: This was a retrospective outcome analysis of data collected from a consecutive series of 4094 patients with burns admitted to a tertiary referral, metropolitan teaching hospital between 1972 and 1996, Results: The overall mortality rate was 3.6 per cent. This decreased from 5.3 per cent (1972-1980) to 3.4 per cent (1993-1996) (P = 0.076). The risk of death was increased with increasing burn size (relative risk (RR) 95.90 (95 per cent confidence interval 12.60-729.47) if more than 35 per cent of the total body surface area was burned; P < 0.001) increasing age (RR 7.32 (3.08-17.42) if aged more than 48 years; P < 0.001), inhalation injury (RR 3.61 (2.39-5.47); P < 0.001) and female sex (RR 1.82 (1.23-2.69); P = 0.003). Operative intervention (RR 0.11 (0.06-0.21); P < 0.001) and the presence of an upper limb burn (RR 0.53 (0.35-0.79); P = 0.002) decreased the risk. Conclusion: Modern burn care has decreased the mortality rate. Increasing burn size, increasing age, inhalation injury and female sex increased, while operative intervention and an upper limb burn decreased, the risk of death.
Resumo:
Vapotronics Inc. is developing the thermal inkjet (TIJ) technology used extensively in the printer industry to create a digital aerosol inhaler for the inhalation of therapeutics for local and systemic delivery. The operation of thermal inkjet printers requires generation of high temperatures and vaporization of the liquid formulation to effect droplet ejection. A study was conducted to develop formulations that would permit the generation of aerosols of therapeutic proteins without damage to the inkjet system or degradation of the proteins. Two proteins, human growth hormone and insulin, were formulated and aerosolized. The aerosol was collected and subjected to assays to compare the physicochemical and biological activities of these proteins before and after aerosolization. In each case, there was no significant changes to the proteins as a result of the aerosolization, providing evidence that TIJ can be used for aerosolizing solutions of protein therapeutics.
Resumo:
Today, the standard approach for the kinetic analysis of dynamic PET studies is compartment models, in which the tracer and its metabolites are confined to a few well-mixed compartments. We examine whether the standard model is suitable for modern PET data or whether theories including more physiologic realism can advance the interpretation of dynamic PET data. A more detailed microvascular theory is developed for intravascular tracers in single-capillary and multiple-capillary systems. The microvascular models, which account for concentration gradients in capillaries, are validated and compared with the standard model in a pig liver study. Methods: Eight pigs underwent a 5-min dynamic PET study after O-15-carbon monoxide inhalation. Throughout each experiment, hepatic arterial blood and portal venous blood were sampled, and flow was measured with transit-time flow meters. The hepatic dual-inlet concentration was calculated as the flow-weighted inlet concentration. Dynamic PET data were analyzed with a traditional single-compartment model and 2 microvascular models. Results: Microvascular models provided a better fit of the tissue activity of an intravascular tracer than did the compartment model. In particular, the early dynamic phase after a tracer bolus injection was much improved. The regional hepatic blood flow estimates provided by the microvascular models (1.3 +/- 0.3 mL min(-1) mL(-1) for the single-capillary model and 1.14 +/- 0.14 min(-1) mL(-1) for the multiple-capillary model) (mean +/- SEM mL of blood min(-1) mL of liver tissue(-1)) were in agreement with the total blood flow measured by flow meters and normalized to liver weight (1.03 +/- 0.12 mL min(-1) mL(-1)). Conclusion: Compared with the standard compartment model, the 2 microvascular models provide a superior description of tissue activity after an intravascular tracer bolus injection. The microvascular models include only parameters with a clear-cut physiologic interpretation and are applicable to capillary beds in any organ. In this study, the microvascular models were validated for the liver and provided quantitative regional flow estimates in agreement with flow measurements.
Resumo:
Modeling physiological processes using tracer kinetic methods requires knowledge of the time course of the tracer concentration in blood supplying the organ. For liver studies, however, inaccessibility of the portal vein makes direct measurement of the hepatic dual-input function impossible in humans. We want to develop a method to predict the portal venous time-activity curve from measurements of an arterial time-activity curve. An impulse-response function based on a continuous distribution of washout constants is developed and validated for the gut. Experiments with simultaneous blood sampling in aorta and portal vein were made in 13 anesthetized pigs following inhalation of intravascular [O-15] CO or injections of diffusible 3-O[ C-11] methylglucose (MG). The parameters of the impulse-response function have a physiological interpretation in terms of the distribution of washout constants and are mathematically equivalent to the mean transit time ( T) and standard deviation of transit times. The results include estimates of mean transit times from the aorta to the portal vein in pigs: (T) over bar = 0.35 +/- 0.05 min for CO and 1.7 +/- 0.1 min for MG. The prediction of the portal venous time-activity curve benefits from constraining the regression fits by parameters estimated independently. This is strong evidence for the physiological relevance of the impulse-response function, which includes asymptotically, and thereby justifies kinetically, a useful and simple power law. Similarity between our parameter estimates in pigs and parameter estimates in normal humans suggests that the proposed model can be adapted for use in humans.