246 resultados para Proportional representation system
Resumo:
The movements of the ricefield rats (Rattus argentiventer) near a trap-barrier system (TBS) were assessed in lowland flood-irrigated rice crops in West Java, Indonesia, to test the hypothesis that a TBS with a 'trap-crop' modifies the movements of rats within 200 m from the trap-crop. The home range use and locations of rat burrows were assessed using radiotelemetry at two sites, one with a TBS with trap-crop (Treatment site, the crop inside the fence was planted 3 weeks earlier than the surrounding crop) and the other with a TBS without trap-crop (Control site, the crop inside the fence was planted at the same time as the surrounding crop). Each TBS was a 50 x 50 m plastic fence with eight multiple-capture rat traps set at the base. More than 700 rats were caught in the TBS with trap-crop, whereas only 10 rats were caught in the TBS without trap-crop. The home range size of females was significantly smaller at the Treatment site (0.96 ha) than the Control site (2.99 ha), but there was no difference for males. Seventy-eight per cent of rats caught in the TBS and fitted with radiocollars had their daytime burrow locations within 200 m of the TBS. We could not determine if the rats caught in the TBS were residents or transients according to demographic parameters. Our results support the hypothesis that a TBS with a trap-crop protects the surrounding rice crop out to a distance of at least 200 m.
Resumo:
We analyzed the mouse Representative Transcript and Protein Set for molecules involved in brain function. We found full-length cDNAs of many known brain genes and discovered new members of known brain gene families, including Family 3 G-protein coupled receptors, voltage-gated channels, and connexins. We also identified previously unknown candidates for secreted neuroactive molecules. The existence of a large number of unique brain ESTs suggests an additional molecular complexity that remains to be explored. A list of genes containing CAG stretches in the coding region represents a first step in the potential identification of candidates for hereditary neurological disorders.
Resumo:
The volume of the primary (PCS) and secondary (SCS) circulatory system in the Atlantic cod Gadus morhua was determined using a modified dye dilution technique. Cod (N=10) were chronically cannulated in the second afferent branchial artery with PE-50 tubing. Evans Blue dye was bound to harvested fish plasma at a concentration of 1 mg dye ml(-1) plasma, and injected at a concentration of 1 mg kg(-1) body mass. Serial sampling from the cannula produced a dye dilution curve, which could be described by a double exponential decay equation. Curve analysis enabled the calculation of the primary circulatory and total distribution volume. The difference between these volumes is assumed to be the volume of the SCS. From the dilution curve, it was also possible to calculate flow rates between and within the systems. The results of these experiments suggest a plasma volume in the PCS of 3.42+/-0.89 ml 100 g(-1) body mass, and in the SCS of 1.68+/-0.35 ml 100 g(-1) body mass (mean +/- S.D.) or approximately 50% that of the PCS. Flow rates to the SCS were calculated as 2.7% of the resting cardiac output. There was an allometric relationship between body mass and blood volumes. Increasing condition factor showed a tendency towards smaller blood volumes of the PCS, expressed as percentage body mass, but this was not evident for the volume of the SCS.
Resumo:
Objectives: The aim was to determine whether methadone maintenance treatment reduced heroin use, syringe sharing and HIV or hepatitis C incidence among prisoners. Methods: All eligible prisoners seeking drug treatment were randomised to methadone or a waitlist control group from 1997 to 1998 and followed up after 4 months. Heroin use was measured by hair analysis and self report; drugs used and injected and syringe sharing were measured by self report. Hepatitis C and HIV incidence was measured by serology. Results: Of 593 eligible prisoners, 382 (64%) were randomised to MMT (n = 191) or control (n = 191). 129 treated and 124 control subjects were followed up at 5 months. Heroin use was significantly lower among treated than control subjects at follow up. Treated subjects reported lower levels of drug injection and syringe sharing at follow up. There was no difference in HIV or hepatitis C incidence. Conclusions: Consideration should be given to the introduction of prison methadone programs particular where community based programs exist. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Incursions of Japanese encephalitis (JE) virus into northern Queensland are currently monitored using sentinel pigs. However, the maintenance of these pigs is expensive, and because pigs are the major amplifying hosts of the virus, they may contribute to JE transmission. Therefore, we evaluated a mosquito-based detection system to potentially replace the sentinel pigs. Single, inactivated JE-infected Culex annulirostris Skuse and C. sitiens Wiedemann were placed into pools of uninfected mosquitoes that were housed in a Mosquito Magnet Pro (MM) trap set under wet season field conditions in Cairns, Queensland for 0, 7, or 14 d. JE viral RNA was detected (cycling threshold [CT] = 40) in 11/ 12, 10/14, and 2/5 pools containing 200, 1,000, and 5,000 mosquitoes, respectively, using a TaqMan real-time reverse transcription-polymerase chain reaction (RT-PCR). The ability to detect virus was not affected by the length of time pools were maintained under field conditions, although the CT score tended to increase with field exposure time. Furthermore, JE viral RNA was detected in three pools of 1,000 mosquitoes collected from Badu Island using a MM trap. These results indicated that a mosquito trap system employing self-powered traps, such as the MosquitoMagnet, and a real-time PCR system, could be used to monitor for JE in remote areas.
Resumo:
BP Refinery (Bulwer Island) Ltd (BP) located on the eastern Australian coast is currently undergoing a major expansion as a part of the Queensland Clean Fuels Project. The associated wastewater treatment plant upgrade will provide a better quality of treated effluent than is currently possible with the existing infrastructure, and which will be of a sufficiently high standard to meet not only the requirements of imposed environmental legislation but also BP's environmental objectives. A number of challenges were faced when considering the upgrade, particularly; cost constraints and limited plot space, highly variable wastewater, toxicity issues, and limited available hydraulic head. Sequencing Batch Reactor (SBR) Technology was chosen for the lagoon upgrade based on the following; SBR technology allowed a retro-fit of the existing earthen lagoon without the need for any additional substantial concrete structures, a dual lagoon system allowed partial treatment of wastewaters during construction, SBRs give substantial process flexibility, SBRs have the ability to easily modify process parameters without any physical modifications, and significant cost benefits. This paper presents the background to this application, an outline of laboratory studies carried out on the wastewater and details the full scale design issues and methods for providing a cost effective, efficient treatment system using the existing lagoon system.
Resumo:
Bound and resonance states of HO2 have been calculated quantum mechanically by the Lanczos homogeneous filter diagonalization method [Zhang and Smith, Phys. Chem. Chem. Phys. 3, 2282 (2001); J. Chem. Phys. 115, 5751 (2001)] for nonzero total angular momentum J = 1,2,3. For lower bound states, agreement between the results in this paper and previous work is quite satisfactory; while for high lying bound states and resonances these are the first reported results. A helicity quantum number V assignment (within the helicity conserving approximation) is performed and the results indicate that for lower bound states it is possible to assign the V quantum numbers unambiguously, but for resonances it is impossible to assign the V helicity quantum numbers due to strong mixing. In fact, for the high-lying bound states, the mixing has already appeared. These results indicate that the helicity conserving approximation is not good for the resonance state calculations and exact quantum calculations are needed to accurately describe the reaction dynamics for HO2 system. Analysis of the resonance widths shows that most of the resonances are overlapping and the interferences between them lead to large fluctuations from one resonance to another. In accord with the conclusions from earlier J = 0 calculations, this indicates that the dissociation of HO2 is essentially irregular. (C) 2003 American Institute of Physics.
Resumo:
Background Patients with known or suspected coronary disease are often investigated to facilitate risk assessment. We sought to examine the cost-effectiveness of strategies based on exercise echocardiography and exercise electrocardiography. Methods and results We studied 7656 patients undergoing exercise testing; of whom half underwent exercise echocardiography. Risk was defined with the Duke treadmill score for those undergoing exercise electrocardiography alone, and by the extent of ischaemia by exercise echocardiography. Cox proportional hazards models, risk adjusted for pretest likelihood of coronary artery disease, were used to estimate time to cardiac death or myocardial infarction. Costs (including diagnostic and revascularisation procedures, hospitalisations, and events) were calculated, inflation-corrected to year 2000 using Medicare trust fund rates and discounted at a rate of 5%. A decision model was employed to assess the marginal cost effectiveness (cost/life year saved) of exercise echo compared with exercise electrocardiography. Exercise echocardiography identified more patients as low-risk (51% vs 24%, p<0.001), and fewer as intermediate- (27% vs 51%, p<0.001) and high-risk (22% vs 4%); survival was greater in low- and intermediate- risk and less in high-risk patients. Although initial procedural costs and revascularisation costs (in intermediate- high risk patients) were greater, exercise echocardiography was associated with a greater incremental life expectancy (0.2 years) and a lower use of additional diagnostic procedures when compared with exercise electrocardiography (especially in lower risk patients). Using decision analysis, exercise echocardiography (Euro 2615/life year saved) was more cost effective than exercise electrocardiography. Conclusion Exercise echocardiography may enhance cost-effectiveness for the detection and management of at risk patients with known or suspected coronary disease. (C) 2003 Published by Elsevier Science Ltd on behalf of The European Society of Cardiology.
Resumo:
Objective: To develop a 'quality use of medicines' coding system for the assessment of pharmacists' medication reviews and to apply it to an appropriate cohort. Method: A 'quality use of medicines' coding system was developed based on findings in the literature. These codes were then applied to 216 (111 intervention, 105 control) veterans' medication profiles by an independent clinical pharmacist who was supported by a clinical pharmacologist with the aim to assess the appropriateness of pharmacy interventions. The profiles were provided for veterans participating in a randomised, controlled trial in private hospitals evaluating the effect of medication review and discharge counselling. The reliability of the coding was tested by two independent clinical pharmacists in a random sample of 23 veterans from the study population. Main outcome measure: Interrater reliability was assessed by applying Cohen's kappa score on aggregated codes. Results: The coding system based on the literature consisted of 19 codes. The results from the three clinical pharmacists suggested that the original coding system had two major problems: (a) a lack of discrimination for certain recommendations e. g. adverse drug reactions, toxicity and mortality may be seen as variations in degree of a single effect and (b) certain codes e. g. essential therapy were in low prevalence. The interrater reliability for an aggregation of all codes into positive, negative and clinically non-significant codes ranged from 0.49-0.58 (good to fair). The interrater reliability increased to 0.72-0.79 (excellent) when all negative codes were excluded. Analysis of the sample of 216 profiles showed that the most prevalent recommendations from the clinical pharmacists were a positive impact in reducing adverse responses (31.9%), an improvement in good clinical pharmacy practice (25.5%) and a positive impact in reducing drug toxicity (11.1%). Most medications were assigned the clinically non-significant code (96.6%). In fact, the interventions led to a statistically significant difference in pharmacist recommendations in the categories; adverse response, toxicity and good clinical pharmacy practice measured by the quality use of medicine coding system. Conclusion: It was possible to use the quality use of medicine coding system to rate the quality and potential health impact of pharmacists' medication reviews, and the system did pick up differences between intervention and control patients. The interrater reliability for the summarised coding system was fair, but a larger sample of medication regimens is needed to assess the non-summarised quality use of medicines coding system.
Resumo:
This paper delineates the development of a prototype hybrid knowledge-based system for the optimum design of liquid retaining structures by coupling the blackboard architecture, an expert system shell VISUAL RULE STUDIO and genetic algorithm (GA). Through custom-built interactive graphical user interfaces under a user-friendly environment, the user is directed throughout the design process, which includes preliminary design, load specification, model generation, finite element analysis, code compliance checking, and member sizing optimization. For structural optimization, GA is applied to the minimum cost design of structural systems with discrete reinforced concrete sections. The design of a typical example of the liquid retaining structure is illustrated. The results demonstrate extraordinarily converging speed as near-optimal solutions are acquired after merely exploration of a small portion of the search space. This system can act as a consultant to assist novice designers in the design of liquid retaining structures.
Resumo:
This paper describes a coupled knowledge-based system (KBS) for the design of liquid-retaining structures, which can handle both the symbolic knowledge processing based on engineering heuristics in the preliminary synthesis stage and the extensive numerical crunching involved in the detailed analysis stage. The prototype system is developed by employing blackboard architecture and a commercial shell VISUAL RULE STUDIO. Its present scope covers design of three types of liquid-retaining structures, namely, a rectangular shape with one compartment, a rectangular shape with two compartments and a circular shape. Through custom-built interactive graphical user interfaces, the user is directed throughout the design process, which includes preliminary design, load specification, model generation, finite element analysis, code compliance checking and member sizing optimization. It is also integrated with various relational databases that provide the system with sectional properties, moment and shear coefficients and final member details. This system can act as a consultant to assist novice designers in the design of liquid-retaining structures with increase in efficiency and optimization of design output and automated record keeping. The design of a typical example of the liquid-retaining structure is also illustrated. (C) 2003 Elsevier B.V All rights reserved.
Resumo:
Frequency deviation is a common problem for power system signal processing. Many power system measurements are carried out in a fixed sampling rate assuming the system operates in its nominal frequency (50 or 60 Hz). However, the actual frequency may deviate from the normal value from time to time due to various reasons such as disturbances and subsequent system transients. Measurement of signals based on a fixed sampling rate may introduce errors under such situations. In order to achieve high precision signal measurement appropriate algorithms need to be employed to reduce the impact from frequency deviation in the power system data acquisition process. This paper proposes an advanced algorithm to enhance Fourier transform for power system signal processing. The algorithm is able to effectively correct frequency deviation under fixed sampling rate. Accurate measurement of power system signals is essential for the secure and reliable operation of power systems. The algorithm is readily applicable to such occasions where signal processing is affected by frequency deviation. Both mathematical proof and numerical simulation are given in this paper to illustrate robustness and effectiveness of the proposed algorithm. Crown Copyright (C) 2003 Published by Elsevier Science B.V. All rights reserved.
Resumo:
The integrated control of nitrate recirculation and external carbon addition in a predenitrification biological wastewater treatment system is studied. The proposed control structure consists of four feedback control loops, which manipulate the nitrate recirculation and the carbon dosage flows in a highly coordinated manner such that the consumption of external carbon is minimised while the nitrate discharge limits (based on both grab and composite samples) are met. The control system requires the measurement of the nitrate concentrations at the end of both the anoxic and the aerobic zones. Distinct from ordinary control systems, which typically minimise the variation in the controlled variables, the proposed control system essentially maximises the diurnal variation of the effluent nitrate concentration and through this maximises the use of influent COD for denitrification, thus minimising the requirement for external carbon source. Simulation studies using a commonly accepted simulation benchmark show that the controlled system consistently achieves the designated effluent quality with minimum costs.