224 resultados para Kinetics analysis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of various culture parameters on the attachment of a recombinant baculovirus to suspended insect cells was examined under normal culture conditions. These parameters included cell density, multiplicity of infection, and composition of the cell growth medium. It was found that the fractional rate of virus attachment was independent of the multiplicity of infection but dependent on the cell density. A first order mathematical model was used to simulate the adsorption kinetics and predict the efficiency of virus attachment under the various culture conditions. This calculated efficiency of virus attachment was observed to decrease at high cell densities, which was attributed to cell clumping. It was also observed that virus attachment was more efficient in Sf900II serum free medium than it was in IPL-41 serum-supplemented medium. This effect was attributed to the protein in serum which may coat the cells and so inhibit adsorption. A general discussion relating the observations made in-these experiments to the kinetics of recombinant baculovirus adsorption to suspended insect cells is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An important consideration in the development of mathematical models for dynamic simulation, is the identification of the appropriate mathematical structure. By building models with an efficient structure which is devoid of redundancy, it is possible to create simple, accurate and functional models. This leads not only to efficient simulation, but to a deeper understanding of the important dynamic relationships within the process. In this paper, a method is proposed for systematic model development for startup and shutdown simulation which is based on the identification of the essential process structure. The key tool in this analysis is the method of nonlinear perturbations for structural identification and model reduction. Starting from a detailed mathematical process description both singular and regular structural perturbations are detected. These techniques are then used to give insight into the system structure and where appropriate to eliminate superfluous model equations or reduce them to other forms. This process retains the ability to interpret the reduced order model in terms of the physico-chemical phenomena. Using this model reduction technique it is possible to attribute observable dynamics to particular unit operations within the process. This relationship then highlights the unit operations which must be accurately modelled in order to develop a robust plant model. The technique generates detailed insight into the dynamic structure of the models providing a basis for system re-design and dynamic analysis. The technique is illustrated on the modelling for an evaporator startup. Copyright (C) 1996 Elsevier Science Ltd

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this second paper, the three structural measures which have been developed are used in the modelling of a three stage centrifugal synthesis gas compressor. The goal of this case study is to determine the essential mathematical structure which must be incorporated into the compressor model to accurately model the shutdown of this system. A simple, accurate and functional model of the system is created via three structural measures. It was found that the model can be correctly reduced into its basic modes and that the order of the differential system can be reduced from 51(st) to 20(th). Of the 31 differential equational 21 reduce to algebraic relations, 8 become constants and 2 can be deleted thereby increasing the algebraic set from 70 to 91 equations. An interpretation is also obtained as to which physical phenomena are dominating the dynamics of the compressor add whether the compressor will enter surge during the shutdown. Comparisons of the reduced model performance against the full model are given, showing the accuracy and applicability of the approach. Copyright (C) 1996 Elsevier Science Ltd

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technical reliability (i.e., interinstrument and interoperator reliability) of three SEAC-swept frequency bioimpedance monitors was assessed for both errors of measurement and associated analyses. In addition, intraoperator and intrainstrument variability was evaluated for repeat measures over a 4-hour period. The measured impedance values from a range of resistance-capacitance circuits were accurate to within 3% of theoretical values over a range of 50-800 ohms. Similarly, phase was measured over the range 1 degrees-19 degrees with a maximum deviation of 1.3 degrees from the theoretical value. The extrapolated impedance at zero frequency was equally well determined (+/-3%). However, the accuracy of the extrapolated value at infinite frequency was decreased, particularly at impedances below 50 ohms (approaching the lower limit of the measurement range of the instrument). The interinstrument/operator variation for whole body measurements were recorded on human volunteers with biases of less than +/-1% for measured impedance values and less than 3% for phase. The variation in the extrapolated values of impedance at zero and infinite frequencies included variations due to operator choice of the analysis parameters but was still less than +/-0.5%. (C) 1997 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although planning is important for the functioning of patients with dementia of the Alzheimer Type (DAT), little is known about response programming in DAT. This study used a cueing paradigm coupled with quantitative kinematic analysis to document the preparation and execution of movements made by a group of 12 DAT patients and their age and sex matched controls. Participants connected a series of targets placed upon a WACOM SD420 graphics tablet, in response to the pattern of illumination of a set of light emitting diodes (LEDs). In one condition, participants could programme the upcoming movement, whilst in another they were forced to reprogramme this movement on-line (i.e. they were not provided with advance information about the location of the upcoming target). DAT patients were found to have programming deficits, taking longer to initiate movements; particularly in the absence of cues. While problems spontaneously programming a movement might cause a greater reliance upon on-line guidance, when both groups were required to guide the movement on-line, DAT patients continued to show slower and less efficient movements implying declining sensori-motor function; these differences were not simply due to strategy or medication status. (C) 1997 Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biologic valve re-replacement was examined in a series of 1343 patients who underwent aortic valve replacement at The Prince Charles Hospital, Brisbane, with a cryopreserved or 4 degrees C stored allograft valve or a xenograft valve, A parametric model approach was used to simultaneously model the competing risks of death without re-replacement and re-replacement before death, One hundred eleven patients underwent a first re-replacement for a variety of reasons (69 patients with xenograft valves, 28 patients with 4 degrees C stored allograft valves, and 14 patients with cryopreserved allograft valves), By multivariable analysis younger age at operation was associated with xenograft, 4 degrees C stored allograft, and cryopreserved allograft valve re-replacement, However, this effect was examined in the context of longer survival of younger patients, which increases their exposure to the risk of re-replacement as compared with that in older patients whose decreased survival reduced their probability of requiring valve re-replacement, In patients older than 60 years at the time of aortic valve replacement, the probability of re-replacement (for any reason) before death was similar for xenografts and cryopreserved allograft valves but higher for 4 degrees C stored valves, However, in patients younger than 60 years, the probability of re-replacement at any time during the remainder of the life of the patient was lower with the cryopreserved allograft valve compared with the xenograft valve and 4 degrees C stored allografts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The classification rules of linear discriminant analysis are defined by the true mean vectors and the common covariance matrix of the populations from which the data come. Because these true parameters are generally unknown, they are commonly estimated by the sample mean vector and covariance matrix of the data in a training sample randomly drawn from each population. However, these sample statistics are notoriously susceptible to contamination by outliers, a problem compounded by the fact that the outliers may be invisible to conventional diagnostics. High-breakdown estimation is a procedure designed to remove this cause for concern by producing estimates that are immune to serious distortion by a minority of outliers, regardless of their severity. In this article we motivate and develop a high-breakdown criterion for linear discriminant analysis and give an algorithm for its implementation. The procedure is intended to supplement rather than replace the usual sample-moment methodology of discriminant analysis either by providing indications that the dataset is not seriously affected by outliers (supporting the usual analysis) or by identifying apparently aberrant points and giving resistant estimators that are not affected by them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transport in bidisperse adsorbents is investigated here, while incorporating a two-dimensional model for adsorbate diffusion in the microparticles. The latter treatment permits consideration of the macropore concentration variation around the microparticle surface, and thereby predicts an adsorbate through-flux on the macroscopic coordinate. Such a through-flux has earlier been postulated in the literature, but with unrealistic mechanistic justification. The new model therefore resolves the existing ambiguity in this regard, and covers the entire spectrum of behaviour between microparticle and macropore diffusion control. Computational results show that if the macroscopic adsorbate flux, ignored in the conventional analysis, has a significant contribution to the total flux under macropore control conditions then it is always important even when the microparticle diffusion resistance is not negligible. The effect of various parameters such as relative microparticle size and isotherm heterogeneity on the uptake is also studied and discussed. (C) 1997 Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Workplace injuries at the University of Queensland Dental School during the period 1992-1994 were assessed to determine their incidence, and the associated indirect costs, causal factors, and appropriate preventive strategies. Overall, dental chairside assistants experienced a higher incidence of injuries than students both on a per worker and per time basis. Of the injuries with a low risk of cross-infection, burns and scalds from sterilizing equipment, and eye injuries in laboratories were the most common. This emphasizes the importance of wearing appropriate protective equipment in areas outside the treatment zone, and the need for signage and education. Common causes of sharps injuries were burs left in handpieces, two-handed needle recapping, and cleaning of probes in the sterilizing room. Changes to techniques and equipment would prevent such incidents. A range of factors which contribute to the calculation of indirect costs following injuries in the dental workplace are identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Elevated concentrations of plasma tumour necrosis factor (TNF)-alpha, interleukin (IL)-1 and IL-6 have been detected in patients with alcoholic hepatitis and have been implicated in the pathogenesis of hepatocyte necrosis. The present study used a rat model to conduct a detailed histological and biochemical examination of the expression of various pro-inflammatory cytokines and associated liver pathology in ethanol-potentiated lipopolysaccharide (LPS)-induced liver injury. Male Wistar rats were pair-fed either the control or ethanol-containing (36% of caloric intake as ethanol) form of the Lieber-DeCarli liquid diet for 6 weeks. Liver injury was induced by the i.v. injection of LPS (1 mu g/g bodyweight), with animals being killed at O, 1, 3, 6, 12 and 24 h after injection. At the later time points, plasma transaminase and transpeptidase activities were significantly elevated in ethanol-fed LPS-treated rats compared with control-fed LPS-treated animals. At these times after LPS treatment, hepatocytes in ethanol-fed animals displayed fatty change and necrosis with an associated neutrophil polymorph infiltrate. Time course analysis revealed that plasma TNF-alpha (1-3 h post-LPS) and IL-6 (3 h post-LPS) bioactivity was significantly elevated in ethanol-fed compared with control-fed animals. No difference was seen in plasma IL-1 alpha concentration (maximal in both groups 6 h post-LPS). The expression of TNF-alpha, IL-1 alpha, IL-1 beta and IL-6 mRNA were elevated between 1 and 6 h post-LPS in the livers of both control and ethanol-fed rats. However, ethanol-fed LPS-treated animals exhibited significantly higher maximal expression of IL-1 and IL-6 mRNA. Comparison of the appearance of cytokine mRNA and plasma bioactivity indicated an effect of ethanol feeding on post-transcriptional processing and/or the kinetics of the circulating cytokines. Elevated levels of both hepatic cytokine mRNA expression and the preceding plasma cytokines are presumably a necessary prerequisite for hepatic injury seen in this model and, therefore, possibly for the damage seen in human alcoholics. Further studies using this model may lead to significant advances in our understanding of the pathogenic mechanisms of alcoholic liver disease in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The kinetics of mechanical alloying have been investigated by examining the effect that ball mass has on the rate at which titanium carbide forms from the elements. By varying the ball density while keeping the ball diameter and the charge ratio constant, the collision energy was independently controlled. Grinding media with a density from 3.8 g cm(-3) (agate) to 16.4 g cm(-3) (tungsten carbide) were used. The reaction rate increases exponentially with ball mass until a critical level is reached, which is determined by the induced temperature rise. Above this level, collisions of higher energy have no advantage. It is also shown that the reaction rate increases exponentially with the rate at which strain accumulates in the reactants. It is suggested that the strain accumulation rate in mechanically induced reactions is analogous to temperature in thermally induced chemical reactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method to measure Escherichia coil cell debris size after homogenization is presented. It is based on cumulative sedimentation analysis under centrifugal force, coupled with Sodium Dodecyl Sulfate-Polyacrylamide Gel Electrophoresis (SDS-PAGE) analysis of sedimented proteins. The effects that fermentation and homogenization conditions have on the resulting debris distributions were investigated using this method. Median debris size decreased significantly from approximately 0.5 mu m to 0.3 mu m as the number of homogenization passes increased from 2 to 10. Under identical homogenization conditions, uninduced host cells in stationary phase had a larger debris size than exponential cells after 5 homogenizer passes. This difference was not evident after 2 or in passes, possibly because of confounding intact cells and the existence of a minimum debris size for the conditions investigated. Recombinant cells containing protein inclusion bodies had the smallest debris size following homogenization. The method was also used to measure the size distribution of inclusion bodies. This result compared extremely well with an independent determination using centrifugal disc photosedimentation (CDS), thus validating the method. This is the first method that provides accurate size distributions of E. coli debris without the need for sample pretreatment, theoretical approximations (e.g. extinction coefficients), or the separation of debris and inclusion bodies prior to analysis. (C) 1997 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Titanium carbonitride-based cermets are important materials for contemporary cutting tools. Ceramic powders of Ti(CN), TaC, WC were mixed, compacted and heat-treated at high temperatures to form (Ti, W, Ta)(C, N) solid solution, which was then ball-milled to fine powders before being mixed with metallic binder and compacted. Liquid-phase sintering of the samples was carried out in a nitrogen atmosphere at different sintering temperatures and holding times. The microhardness and porosity of the sintered cermets were studied. It is demonstrated that the microhardness increases with sintering temperature, but at the same time, the porosity level also goes up with temperature and time. At the beginning of sintering (zero holding time), the majority of the pores are small (0.1 similar to 1 mu m); during sintering, the larger ports grow at the expense of smaller pores and the resulting pores are all concentrated in the 10 similar to 100 mu m range. The number of larger pores increases with temperature and prolonged holding time, which results in deteriorated properties. (C) 1997 Elsevier Science S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An algorithm for explicit integration of structural dynamics problems with multiple time steps is proposed that averages accelerations to obtain subcycle states at a nodal interface between regions integrated with different time steps. With integer time step ratios, the resulting subcycle updates at the interface sum to give the same effect as a central difference update over a major cycle. The algorithm is shown to have good accuracy, and stability properties in linear elastic analysis similar to those of constant velocity subcycling algorithms. The implementation of a generalised form of the algorithm with non-integer time step ratios is presented. (C) 1997 by John Wiley & Sons, Ltd.