217 resultados para Intensive longitudinal design
Resumo:
Two hazard risk assessment matrices for the ranking of occupational health risks are described. The qualitative matrix uses qualitative measures of probability and consequence to determine risk assessment codes for hazard-disease combinations. A walk-through survey of an underground metalliferous mine and concentrator is used to demonstrate how the qualitative matrix can be applied to determine priorities for the control of occupational health hazards. The semi-quantitative matrix uses attributable risk as a quantitative measure of probability and uses qualitative measures of consequence. A practical application of this matrix is the determination of occupational health priorities using existing epidemiological studies. Calculated attributable risks from epidemiological studies of hazard-disease combinations in mining and minerals processing are used as examples. These historic response data do not reflect the risks associated with current exposures. A method using current exposure data, known exposure-response relationships and the semi-quantitative matrix is proposed for more accurate and current risk rankings.
Resumo:
The problem of designing spatially cohesive nature reserve systems that meet biodiversity objectives is formulated as a nonlinear integer programming problem. The multiobjective function minimises a combination of boundary length, area and failed representation of the biological attributes we are trying to conserve. The task is to reserve a subset of sites that best meet this objective. We use data on the distribution of habitats in the Northern Territory, Australia, to show how simulated annealing and a greedy heuristic algorithm can be used to generate good solutions to such large reserve design problems, and to compare the effectiveness of these methods.
Resumo:
In many occupational safety interventions, the objective is to reduce the injury incidence as well as the mean claims cost once injury has occurred. The claims cost data within a period typically contain a large proportion of zero observations (no claim). The distribution thus comprises a point mass at 0 mixed with a non-degenerate parametric component. Essentially, the likelihood function can be factorized into two orthogonal components. These two components relate respectively to the effect of covariates on the incidence of claims and the magnitude of claims, given that claims are made. Furthermore, the longitudinal nature of the intervention inherently imposes some correlation among the observations. This paper introduces a zero-augmented gamma random effects model for analysing longitudinal data with many zeros. Adopting the generalized linear mixed model (GLMM) approach reduces the original problem to the fitting of two independent GLMMs. The method is applied to evaluate the effectiveness of a workplace risk assessment teams program, trialled within the cleaning services of a Western Australian public hospital.
Resumo:
Red cell number and size increase during puberty, particularly in males. The aim of the present study was to determine whether expression of genes affecting red cell indices varied with age and sex. Haemoglobin, red cell count, and mean cellular volume were measured longitudinally on 578 pairs of twins at twelve, fourteen and sixteen years of age. Data were analysed using a structural equation modeling approach, in which a variety of univariate and longitudinal simplex models were fitted to the data. Significant heritability was demonstrated for all variables across all ages. The genes involved did not differ between the sexes, although there was evidence for sex limitation in the case of haemoglobin at age twelve. Longitudinal analyses indicated that new genes affecting red cell indices were expressed at different stages of puberty. Some of these genes affected the different red cell indices pleiotropically, while others had effects specific to one variable only.
Resumo:
Novel current density mapping (CDM) schemes are developed for the design of new actively shielded, clinical magnetic resonance imaging (MRI) magnets. This is an extended inverse method in which the entire potential solution space for the superconductors has been considered, rather than single current density layers. The solution provides an insight into the required superconducting coil pattern for a desired magnet configuration. This information is then used as an initial set of parameters for the magnet structure, and a previously developed hybrid numerical optimization technique is used to obtain the final geometry of the magnet. The CDM scheme is applied to the design of compact symmetric, asymmetric, and open architecture 1.0-1.5 T MRI magnet systems of novel geometry and utility. A new symmetric 1.0-T system that is just I m in length with a full 50-cm diameter of the active, or sensitive, volume (DSV) is detailed, as well as an asymmetric system in which a 50-cm DSV begins just 14 cm from the end of the coil structure. Finally a 1.0-T open magnet system with a full 50-cm DSV is presented. These new designs provide clinically useful homogeneous regions and have appropriately restricted stray fields but, in some of the designs, the DSV is much closer to the end of the magnet system than in conventional designs. These new designs have the potential to reduce patient claustrophobia and improve physician access to patients undergoing scans. (C) 2002 Wiley Periodicals, Inc.
Resumo:
Radio-frequency (RF) coils are a necessary component of magnetic resonance imaging (MRI) systems. When used in transmit operation, they act to generate a homogeneous RF magnetic field within a volume of interest and when in receive operation, they act to receive the nuclear magnetic resonance signal from the RF-excited specimen. This paper outlines a procedure for the design of open RF coils using the time-harmonic inverse method. This method entails the calculation of an ideal current density on a multipaned planar surface that would generate a specified magnetic field within the volume of interest. Because of the averaging effect of the regularization technique in the matrix solution, the specified magnetic field is shaped within an iterative procedure until the generated magnetic field matches the desired magnetic field. The stream-function technique is used to ascertain conductor positions and a method of moments package is then used to finalize the design. An open head/neck coil was designed to operate in a clinical 2T MRI system and the presented results prove the efficacy of this design methodology.
Resumo:
The complex design and development of a planar multilayer phased array antenna in microstrip technology can be simplified using two commercially available design tools 1) Ansoft Ensemble and 2) HP-EEsof Touchstone. In the approach presented here, Touchstone is used to design RF switches and phase shifters whose scattering parameters are incorporated in Ensemble simulations using its black box tool. Using this approach, Ensemble is able to fully analyze the performance of radiating and beamforming layers of a phased array prior to its manufacturing. This strategy is demonstrated in a design example of a 12-element linearly-polarized circular phased array operating at L band. A comparison between theoretical and experimental results of the array is demonstrated.
Resumo:
The design and development of two X-band amplifying reflectarrays is presented. The arrays use dual-polarized aperture coupled patch antennas with FET transistors and phasing circuits to amplify a microwave signal and to radiate it in a chosen direction. Two cases are considered, one when a reflectarray converts a spherical wave due to a feed horn into a plane wave radiated into a boresight direction, and two, when the reflectarray converts a spherical wave due to a dual-polarized four-element feed array into a co-focal spherical wave. This amplified signal is received in an orthogonal port of the feed array so that the entire structure acts as a spatial power combiner. The two amplifying arrays are tested in the near-field zone for phase distribution over their apertures to achieve the required beam formation. Alternatively, their radiation patterns or gains are investigated.
Resumo:
Murray Valley encephalitis (MVE) virus is a mosquito-borne flavivirus causing severe encephalitis with a resultant high morbidity and mortality. In the period 1989-1993. we undertook a cross-sectional and longitudinal studs by annually screening members of a small remote Aboriginal community in northwestern Australia for MVE virus antibodies. Of the estimated 250-300 people in the community. 249 were tested, and 52.6% had positive serology to MVE. The proportion testing positive increased with increasing age group. and males were slightly more likely to be positive than females. During the study period. a high proportion of the population seroconverted to MVE: the clinical/subclinical ratio seems to be lower than previously reported. Although MVE is mostly asymptomatic, the devastating consequences of clinical illness indicate that advice should be provided regarding the avoidance of mosquito bites. Our longitudinal study showed that the risk of seroconversion was similar for each age group. not just the young.
Resumo:
Design of liquid retaining structures involves many decisions to be made by the designer based on rules of thumb, heuristics, judgment, code of practice and previous experience. Various design parameters to be chosen include configuration, material, loading, etc. A novice engineer may face many difficulties in the design process. Recent developments in artificial intelligence and emerging field of knowledge-based system (KBS) have made widespread applications in different fields. However, no attempt has been made to apply this intelligent system to the design of liquid retaining structures. The objective of this study is, thus, to develop a KBS that has the ability to assist engineers in the preliminary design of liquid retaining structures. Moreover, it can provide expert advice to the user in selection of design criteria, design parameters and optimum configuration based on minimum cost. The development of a prototype KBS for the design of liquid retaining structures (LIQUID), using blackboard architecture with hybrid knowledge representation techniques including production rule system and object-oriented approach, is presented in this paper. An expert system shell, Visual Rule Studio, is employed to facilitate the development of this prototype system. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Background: Tissue Doppler may be used to quantify regional left ventricular function but is limited by segmental variation of longitudinal velocity from base to apex and free to septal walls. We sought to overcome this by developing a composite of longitudinal and radial velocities. Methods and Results. We examined 82 unselected patients undergoing a standard dobutamine echocardiogram. Longitudinal velocity was obtained in the basal and mid segments of each wall using tissue Doppler in the apical views. Radial velocities were derived in the same segments using an automated border detection system and centerline method with regional chords grouped according to segment location and temporally averaged. In 25 patients at low probability of coronary disease, the pattern of regional variation in longitudinal velocity (higher in the septum) was the opposite of radial velocity (higher in the free wall) and the combination was homogenous. In 57 patients undergoing angiography, velocity in abnormal segments was less than normal segments using longitudinal (6.0 +/- 3.6 vs 9.0 +/- 2.2 cm/s, P = .01) and radial velocity (6.0 +/- 4.0 vs 8.0 +/- 3.9 cm/s, P = .02). However, the composite velocity permitted better separation of abnormal and normal segments (13.3 +/- 5.6 vs 17.5 +/- 4.2 cm/s, P = .001). There was no significant difference between the accuracy of this quantitative approach and expert visual wall motion analysis (81% vs 84%, P = .56). Conclusion: Regional variation of uni-dimensional myocardial velocities necessitates site-specific normal ranges, probably because of different fiber directions. Combined analysis of longitudinal and radial velocities allows the derivation of a composite velocity, which is homogenous in all segments and may allow better separation of normal and abnormal myocardium.
Resumo:
Background Systolic myocardial Doppler velocity accurately identifies coronary artery disease. However, these velocities may be affected by age, hemodynamic responses to stress, and left ventricular cavity size. We sought to examine the influences of these variables on myocardial velocity during dobutamine stress in patients with normal wall motion. Methods One hundred seventy-nine consecutive patients with normal dobutamine echocardiograms were studied. Color myocardial tissue Doppler data were obtained at rest and peak stress, and peak systolic myocardial velocity (PSV) was measured in all basal and midventricular segments. Velocities at rest and peak stress were compared with left ventricular diastolic and systolic volumes, blood pressure, heart rate, and age by Pearson correlation and interdecile analysis by use of analysis of variance. Results The only clinical variable correlating with velocity was age; PSV showed only mild correlation with age at rest (r(2) = 0.01, P = .001) and peak stress (r(2) = 0.02, P = .001), but the normal peak velocity was significantly different between the extremes of age (<44 years and >74 years). There was very weak correlation of PSV with systolic and diastolic blood pressure (r(2) < 0.01), heart rate (r(2) < 0.01), systemic vascular resistance (r(2) = 0.08), and left ventricular volumes (r(2) < 0.01). Conclusions Peak systolic velocity during dobutamine stress is relatively independent of hemodynamic factors and left ventricular cavity size. The extremes of age may influence peak systolic Doppler velocities. These results suggest that peak systolic velocity may be a robust quantitative measure during dobutamine echocardiography across most patient subgroups.