144 resultados para FUNCTIONAL INDEPENDENCE MEASURE
Resumo:
Knowledge, especially scientific and technological knowledge, grows according to knowledge trajectories and guideposts that make up the prior knowledge of an organization. We argue that these knowledge structures and their specific components lead to successful innovation. A firm's prior knowledge facilitates the absorption of new knowledge, thereby renewing a firm's systematic search, transfer and acquisition of knowledge and capabilities. In particular, the exponential growth in biotechnology is characterized by the convergence of disparate scientific and technological knowledge resources. This paper examines the shift from protein-based to DNA-based diagnostic technologies as an example, to quantify the value of a firm's prior knowledge using relative values of knowledge distance. The distance between core prior knowledge and the rate of transition from one knowledge system to another has been identified as a proxy for the value a firm's prior knowledge. The overall difficulty of transition from one technology paradigm to another is discussed. We argue this transition is possible when the knowledge distance is minimal and the transition process has a correspondingly high value of absorptive capacities. Our findings show knowledge distance is a determinant of the feasibility, continuity and capture of scientific and technological knowledge. Copyright © 2003 John Wiley & Sons, Ltd.
Resumo:
We have developed a computational strategy to identify the set of soluble proteins secreted into the extracellular environment of a cell. Within the protein sequences predominantly derived from the RIKEN representative transcript and protein set, we identified 2033 unique soluble proteins that are potentially secreted from the cell. These proteins contain a signal peptide required for entry into the secretory pathway and lack any transmembrane domains or intracellular localization signals. This class of proteins, which we have termed the mouse secretome, included >500 novel proteins and 92 proteins
Resumo:
Early pregnancy factor (EPF) is a secreted protein with growth regulatory and immunomodulatory properties. It is an extracellular form of the mitochondrial matrix protein chaperonin 10 (Cpn10), a molecular chaperone. An understanding of the mechanism of action of EPF and an exploration of therapeutic potential has been limited by availability of purified material. The present study was undertaken to develop a simple high-yielding procedure for preparation of material for structure/function studies, which could be scaled up for therapeutic application. Human EPF was expressed in Sf9 insect cells by baculovirus infection and in Escherichia coli using a heat inducible vector. A modified molecule with an additional N-terminal alanine was also expressed in E coli. The soluble protein was purified from cell lysates via anion exchange (negative-binding mode), cation exchange, and hydrophobic interaction chromatography, yielding similar to42 and 36 mg EPF from 300 ml bacterial and I L Sf9 cultures, respectively. The preparations were highly purified ( greater than or equal to99% purity on SDS-PAGE for the bacterial products and greater than or equal to97% for that of insect cells) and had the expected mass and heptameric structure under native conditions, as determined by mass spectrometry and gel permeation chromatography, respectively. All recombinant preparations exhibited activity in the EPF bioassay, the rosette inhibition test, with similar potency both to each other and to the native molecule. In two in vivo assays of immuno suppressive activity, the delayed-type hypersensitivity reaction and experimental autoimmune encephalomyelitis, the insect cell and modified bacterial products, both with N-terminal additions (acetylation or amino acid), exhibited similar levels of suppressive activity, but the bacterial product with no N-terminal modification had no effect in either assay. Studies by others have shown that N-terminal addition is not necessary for Cpn10 activity. By defining techniques for facile production of molecules with and without immunosuppressive properties, the present studies make it possible to explore mechanisms underlying the distinction between EPF and Cpn10 activity. (C) 2003 Elsevier Inc. All rights reserved.
Resumo:
Biogenic amines and their receptors regulate and modulate many physiological and behavioural processes in animals. In vertebrates, octopamine is only found in trace amounts and its function as a true neurotransmitter is unclear. In protostomes, however, octopamine can act as neurotransmitter, neuromodulator and neurohormone. In the honeybee, octopamine acts as a neuromodulator and is involved in learning and memory formation. The identification of potential octopamine receptors is decisive for an understanding of the cellular pathways involved in mediating the effects of octopamine. Here we report the cloning and functional characterization of the first octopamine receptor from the honeybee, Apis mellifera . The gene was isolated from a brain-specific cDNA library. It encodes a protein most closely related to octopamine receptors from Drosophila melanogaster and Lymnea stagnalis . Signalling properties of the cloned receptor were studied in transiently transfected human embryonic kidney (HEK) 293 cells. Nanomolar to micromolar concentrations of octopamine induced oscillatory increases in the intracellular Ca2+ concentration. In contrast to octopamine, tyramine only elicited Ca2+ responses at micromolar concentrations. The gene is abundantly expressed in many somata of the honeybee brain, suggesting that this octopamine receptor is involved in the processing of sensory inputs, antennal motor outputs and higher-order brain functions.
Resumo:
The use of thermodilution and other methods of monitoring in dogs during surgery and critical care was evaluated. Six Greyhounds were anaesthetised and then instrumented by placing a thermodilution catheter into the pulmonary artery via the jugular vein. A catheter in the dorsal pedal artery also permitted direct measurement of arterial pressures. Core body temperature (degreesC) and central venous pressure (mmHg) were measured, while cardiac output (mL/min/kg) and mean arterial pressure (mmHg) were calculated. A mid-line surgical incision was performed and the physiological parameters were monitored for a total of two hours. All physiological parameters generally declined, although significant increases (P<0.05) were noted for cardiac output following surgical incision. Central venous pressure was maintained at approximately 0mmHg by controlling an infusion of sterile saline. Core body temperature decreased from 37.1+/-0.6degreesC (once instrumented) to 36.6+/-0.60degreesC (at the end of the study), despite warming using heating pads. Physiological parameters indicative of patient viability will generally decline during surgery without intervention. This study describes an approach that can be undertaken in veterinary hospitals to accurately monitor vital signs in surgical and critical care patients.
Resumo:
Objective: To examine the association between gain in motor and cognitive functional status with patient satisfaction 3-6 mo after rehabilitation discharge. Design: Patient satisfaction and changes in functional status were examined in 18,375 patients with stroke who received inpatient medical rehabilitation. Information was obtained from 144 hospitals and rehabilitation facilities contributing records to the Uniform Data System for Medical Rehabilitation and the National Follow-up Services. Results: Data analysis revealed significant (P < 0.05) differences in satisfaction responses based on whether information was collected from patient self-report or from a family member proxy, and the two subsets were analyzed separately. Logistic regression revealed the following significant predictors of satisfaction for data collected from stroke patients: cognitive and motor gain, rehospitalization, who the patient was living with at follow-up, age, and follow-up therapy. In the patient-reported data subset, compared with patients who showed improved cognitive or motor functional status, those with no change, respectively, had a 31% and 33% reduced risk of dissatisfaction. In addition, rehospitalized patients had a higher risk of dissatisfaction. For the proxy reported data subset, significant influences on satisfaction were health maintenance, rehospitalization, stroke type, ethnicity, cognitive FIM(TM) gain, length of stay, and follow-up therapy. Conclusions: Ratings of satisfaction with rehabilitation services were affected by change in functional status and whether the information was collected from patient rating or proxy response.
Resumo:
In order to develop a method for use in investigations of spatial biomass distribution in solid-state fermentation systems, confocal scanning laser microscopy was used to determine the concentrations of aerial and penetrative biomass against height and depth above and below the substrate surface, during growth of Rhizopus oligosporus on potato dextrose agar. Penetrative hyphae had penetrated to a depth of 0.445 cm by 64 h and showed rhizoid morphology, in which the maximum biomass concentration, of 4.45 mg dry wt cm(-3), occurred at a depth of 0.075 cm. For aerial biomass the maximum density of 39.54 mg dry wt(-3) occurred at the substrate surface. For both aerial and penetrative biomass, there were two distinct regions in which the biomass concentration decayed exponentially with distance from the surface. For aerial biomass, the first exponential decay region was up to 0.1 cm height. The second region above the height of 0.1 cm corresponded to that in which sporangiophores dominated. This work lays the foundation for deeper studies into what controls the growth of fungal hyphae above and below the surfaces of solid substrates. (C) Wiley Periodicals, Inc.
Resumo:
The equipment used to measure magnetic fields and, electric currents in residences is described. The instrumentation consisted of current transformers, magnetic field probes and locally designed and, built signal conditioning modules. The data acquisition system was capable of unattended recording for extended time periods. The complete system was calibrated to verify its response to known physical inputs. (C) 2003 ISA-The Instrumentation Automation Society.