140 resultados para Drum screen
Resumo:
In standard cylindrical gradient coils consisting of a single layer of wires, a limiting factor in achieving very large magnetic field gradients is the rapid increase in coil resistance with efficiency. This is a particular problem in small-bore scanners, such as those used for MR microscopy. By adopting a multi-layer design in which the coil wires are allowed to spread out into multiple layers wound at increasing radii, a more favourable scaling of resistance with efficiency is achieved, thus allowing the design of more powerful gradient coils with acceptable resistance values. Previously this approach has been applied to the design of unshielded, longitudinal, and transverse gradient coils. Here, the multi-layer approach has been extended to allow the design of actively shielded multi-layer gradient coils, and also to produce coils exhibiting enhanced cooling characteristics. An iterative approach to modelling the steady-state temperature distribution within the coil has also been developed. Results indicate that a good level of screening can be achieved in multi-layer coils, that small versions of such coils can yield higher efficiencies at fixed resistance than conventional two-layer (primary and screen) coils, and that performance improves as the number of layers of increases. Simulations show that by optimising multi-layer coils for cooling it is possible to achieve significantly higher gradient strengths at a fixed maximum operating temperature. A four-layer coil of 8 mm inner diameter has been constructed and used to test the steady-state temperature model. (C) 2003 Elsevier Inc. All rights reserved.
Resumo:
Two methods were compared for determining the concentration of penetrative biomass during growth of Rhizopus oligosporus on an artificial solid substrate consisting of an inert gel and starch as the sole source of carbon and energy. The first method was based on the use of a hand microtome to make sections of approximately 0.2- to 0.4-mm thickness parallel to the substrate surface and the determination of the glucosamine content in each slice. Use of glucosamine measurements to estimate biomass concentrations was shown to be problematic due to the large variations in glucosamine content with mycelial age. The second method was a novel method based on the use of confocal scanning laser microscopy to estimate the fractional volume occupied by the biomass. Although it is not simple to translate fractional volumes into dry weights of hyphae due to the lack of experimentally determined conversion factors, measurement of the fractional volumes in themselves is useful for characterizing fungal penetration into the substrate. Growth of penetrative biomass in the artificial model substrate showed two forms of growth with an indistinct mass in the region close to the substrate surface and a few hyphae penetrating perpendicularly to the surface in regions further away from the substrate surface. The biomass profiles against depth obtained from the confocal microscopy showed two linear regions on log-linear plots, which are possibly related to different oxygen availability at different depths within the substrate. Confocal microscopy has the potential to be a powerful tool in the investigation of fungal growth mechanisms in solid-state fermentation. (C) 2003 Wiley Periodicals, Inc.
Resumo:
Translabial ultrasound is increasingly being used for the assessment of women presenting with pelvic floor dysfunction and incontinence (1,2). However, there is little information on normal values for bladder neck descent, with the two available studies disagreeing widely (3,4). No data has so far been published on mobility of the central and posterior compartment which can now also be assessed by ultrasound (5). This study presents normal values for urethral, bladder, cervical and rectal mobility in a cohort of young, stress continent, nulliparous nonpregnant women. Methods 118 nonpregnant nulliparous Caucasian women between 18 and 23 years of age were recruited for an ongoing twin study of pelvic floor function. Translabial ultrasound assessment of pelvic organ mobility was undertaken supine and after bladder emptying (6,7). The best of at least three effective Valsalva manoeuvres was used for evaluation, with no attempts at standardization of Valsalva pressure. Parameters of anterior compartment mobility were obtained by the use of on-screen calipers; cervical and rectal descent were evaluated on printouts. All examinations were carried out under direct supervision of the first author or by personnel trained by him for at least 100 consecutive assessments. Results The median age of participants in this study was 20 (range 18- 23). Mean body mass index was 23 (range 16.9- 36.7). Of 118 women, 2 were completely unable to perform a Valsalva manoeuvre despite repeated efforts at teaching and were excluded from analysis, as were ten women who complained of urinary stress incontinence, leaving 106 datasets. Average measurements for the parameters ‘retrovesical angle at rest’ (RVA-R) and on Valsalva (RVA-S), urethral rotation, bladder neck mobility, cysto-cele descent, cervical descent and descent of the rectal ampulla are given in Table 1.