89 resultados para thoracolumbar spine


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design, The study group consisted of 53 patients who underwent 75 operations for spine metastases. Patient and tumor demographic factors, preoperative nutritional status, and perioperative adjunctive therapy were retrospectively reviewed. Objective, To determine the risk factors for wound breakdown and infection in patients undergoing surgery for spinal metastases. Summary of Background Data. Spinal Fusion using spine implants may be associated with an infection rate of 5% or more. Surgery for spine metastases is associated with an infection rate of more than 10%. Factors other than the type of surgery performed may account for the greater infection rate. Methods. Data were obtained by reviewing patient records. Age, sex, and neurologic status of the patient; tumor type and site; and surgical details were noted. Adjunctive treatment with corticosteroids and radiotherapy was recorded, Nutritional status was evaluated by determining serum protein and serum albumin concentrations and by total lymphocyte count. Results. Wound breakdown and Infection occurred in 75 of 75 wounds. No patient or tumor demographic factors other than intraoperative blood loss (P < 0.1) were statistically associated with infection; The correlation between preoperative protein deficiency (P < 0.01) or perioperative corticosteroid administration (P < 0.10) and wound infection was significant. There was no statistical correlation between lymphocyte count or perioperative radiotherapy and wound infection. Conclusions, The results indicate that preoperative protein depletion and perioperative administration of corticosteroids are risk factors for wound infection in patients undergoing surgery for spine metastases, Perioperative correction of nutritional depletion and cessation of steroid therapy may reduce wound complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In humans, intra-abdominal pressure (IAP) is elevated during many everyday activities. This experiment aimed to investigate the extent to which increased IAP-without concurrent activity of the abdominal or back extensor muscles-produces an extensor torque. With subjects positioned in side lying on a swivel table with its axis at L3, moments about this vertebral level were measured when IAP was transiently increased by electrical stimulation of the diaphragm via the phrenic nerve. There was no electromyographic activity in abdominal and back extensor muscles. When IAP was increased artificially to similar to 15% of the maximum IAP amplitude that could be generated voluntarily with the trunk positioned in flexion, a trunk extensor moment (similar to6 Nm) was recorded. The size of the effect was proportional to the increase in pressure. The extensor moment was consistent with that predicted from a model based on measurements of abdominal cross-sectional area and IAP moment arm. When IAP was momentarily increased while the trunk was flexed passively at a constant velocity, the external torque required to maintain the velocity was increased. These results provide the first in vivo data of the amplitude of extensor moment that is produced by increased IAP. Although the net effect of this extensor torque in functional tasks would be dependent on the muscles used to increase the IAP and their associated flexion torque, the data do provide evidence that IAP contributes, at least in part, to spinal stability. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Manipulative therapy is frequently used in the management of musculoskeletal pain. A frequently reported clinical feature of this treatment is the immediacy with which it appears to initiate improvement in pain and function. A randomised, double blind, placebo controlled, repeated measures design was employed to study the initial effects of a cervical spine treatment technique in a group of 15 patients with lateral epicondylalgia. Pressure pain threshold, pain-free grip strength, upper limb neurodynamics, pain and function were assessed prior to and following application of either a treatment, placebo or control condition. All subjects received all three conditions. Differences between the pre-post measures were used as indicators of change in subject's symptom profiles. The treatment condition produced significant improvement in pressure pain threshold, pain-free grip strength, neurodynamics and pain scores relative to placebo and control conditions (P < 0.05). In summary, this study demonstrates that manipulative therapy is capable of eliciting a rapid hypoalgesic effect.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of tape to deload soft tissue is used in the management of thoracic spine pain. A reported clinical feature of this treatment is reduced tenderness of the spine during postero-anterior mobilizations. A randomized, single blind, placebo controlled, repeated measures design study was employed to investigate the effects of deloading tape on pressure pain threshold measurements at the level of the T7 spinous process in an asymptomatic group of 24 subjects. Pressure pain thresholds were assessed prior to and following the application of deloading tape, placebo sham tape and no-tape control conditions. All subjects received all three conditions in a randomized order on three separate days. Differences between the pre- and post-measurements were used as indicators of change in a subject's pressure pain threshold. No significant change in pressure pain threshold measurements was found between conditions. In summary, this study demonstrated that deloading tape applied to the level of the T7 spinous process did not significantly change pressure pain threshold measurements in asymptomatic subjects, raising the possibility that any pain relieving effect may well be conditional upon pain being present. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To establish a simple method to quantify muscle/fat constituents in cervical muscles of asymptomatic women using magnetic resonance imaging (MRI), and to determine whether there is an age effect within a defined age range. MATERIALS AND METHODS: MRI of the upper cervical spine was performed for 42 asymptomatic women aged 18-45 years. The muscle and fat signal intensities on axial spin echo T1-weighted images were quantitatively classified by taking a ratio of the pixel intensity profiles of muscle against those of intermuscular fat for the rectus capitis posterior major and minor and inferior obliquus capitis muscles bilaterally. Inter- and intra-examiner agreement was scrutinized. RESULTS: The average relative values of fat within the upper cervical musculature compared with intermuscular fat indicated that there were only slight variations in indices between the three sets of muscles. There was no significant correlation between age and fat indices. There were significant differences for the relative fat within the muscle compared with intermuscular fat and body mass index for the right rectus capitis posterior major and right and left inferior obliquus capitis muscles (p = 0.032). Intraclass correlation coefficients for intraobserver agreement ranged from 0.94 to 0.98. Inter-rater agreement of the measurements ranged from 0.75 to 0.97. CONCLUSION: A quantitative measure of muscle/fat constituents has been developed, and results of this study indicate that relative fatty infiltration is not a feature of age in the upper cervical extensor muscles of women aged 18-45 years. (C) 2005 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intra-abdominal pressure (IAP) increases during many tasks and has been argued to increase stability and stiffness of the spine. Although several studies have shown a relationship between the IAP increase and spinal stability, it has been impossible to determine whether this augmentation of mechanical support for the spine is due to the increase in IAP or the abdominal muscle activity which contributes to it. The present study determined whether spinal stiffness increased when IAP increased without concurrent activity of the abdominal and back extensor muscles. A sustained increase in IAP was evoked by tetanic stimulation of the phrenic nerves either. unilaterally or bilaterally at 20 Hz (for 5 s) via percutaneous electrodes in three subjects. Spinal stiffness was measured as the force required to displace an indentor over the L4 or L2 spinous process with the subjects lying prone. Stiffness was measured as the slope of the regression line fitted to the linear region of the force-displacement curve. Tetanic stimulation of the diaphragm increased IAP by 27-61% of a maximal voluntary pressure increase and increased the stiffness of the spine by 8-31% of resting levels. The increase in spinal stiffness was positively correlated with the size of the IAP increase. IAP increased stiffness at L2 and L4 level. The results of this:study provide evidence that the stiffness of the lumbar spine is increased when IAP is elevated. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The mechanisms by which the abdominal muscles move and control the lumbosacral spine are not clearly understood. Descriptions of abdominal morphology are also conflicting and the regional anatomy of these muscles has not been comprehensively examined. The aim of this study was to investigate the morphology of regions of transversus abdominis and obliquus internus and externus abdominis. Methods. Anterior and posterolateral abdominal walls were dissected bilaterally in 26 embalmed human cadavers. The orientation, thickness and length of the upper, middle and lower fascicles of transversus abdominis and obliquus internus abdominis, and the upper and middle fascicles of obliquus externus abdominis were measured. Findings. Differences in fascicle orientation, thickness and length were documented between the abdominal muscles and between regions of each muscle. The fascicles of transversus abdominis were horizontal in the upper region, with increasing inferomedial orientation in the middle and lower regions. The upper and middle fascicles of obliquus internus abdominis were oriented superomedially and the lower fascicles inferomedially. The mean vertical dimension of transversus abdominis that attaches to the lumbar spine via the thoracolumbar fascia was 5.2 (SD 2.1) cm. Intramuscular septa were observed between regions of transversus abdominis, and obliquus internus abdominis could be separated into two distinct layers in the lower and middle regions. Interpretation. This study provides quantitative data of morphological differences between regions of the abdominal muscles, which suggest variation in function between muscle regions. Precise understanding of abdominal muscle anatomy is required for incorporation of these muscles into biomechanical models. Furthermore, regional variation in their morphology may reflect differences in function. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design. Survey of intraobserver and interobserver measurement variability. Objective. To assess the use of reformatted computerized tomography (CT) images for manual measurement of coronal Cobb angles in idiopathic scoliosis. Summary of Background Data. Cobb angle measurements in idiopathic scoliosis are traditionally made from standing radiographs, whereas CT is often used for assessment of vertebral rotation. Correlating Cobb angles from standing radiographs with vertebral rotations from supine CT is problematic because the geometry of the spine changes significantly from standing to supine positions, and 2 different imaging methods are involved. Methods. We assessed the use of reformatted thoracolumbar CT images for Cobb angle measurement. Preoperative CT of 12 patients with idiopathic scoliosis were used to generate reformatted coronal images. Five observers measured coronal Cobb angles on 3 occasions from each of the images. Intraobserver and interobserver variability associated with Cobb measurement from reformatted CT scans was assessed and compared with previous studies of measurement variability using plain radiographs. Results. For major curves, 95% confidence intervals for intraobserver and interobserver variability were +/- 6.6 degrees and +/- 7.7 degrees, respectively. For minor curves, the intervals were +/- 7.5 degrees and +/- 8.2 degrees, respectively. Intraobserver and interobserver technical error of measurement was 2.4 degrees and 2.7 degrees, with reliability coefficients of 88% and 84%, respectively. There was no correlation between measurement variability and curve severity. Conclusions. Reformatted CT images may be used for manual measurement of coronal Cobb angles in idiopathic scoliosis with similar variability to manual measurement of plain radiographs.