23 resultados para accurate frequencies
Resumo:
We present a new approach for crosshole radio tomography. Conductivity images of the investigated area are reconstructed from the ratio of the electric field intensities measured at two similar frequencies. The method largely avoids assumptions about the radiation pattern and in-situ intensity of the transmitting antenna, which introduce errors in conventional single-frequency crosshole electromagnetic-absorption tomography. Application of the method to field data achieved an improvement in resolution of anomalies over traditional single-frequency absorption tomography. The dual-frequency method is not a universal approach; it is suitable for moderately conductive media (>0.01 S/m) over the approximate frequency range 1-100 MHz.
Resumo:
Objective To improve the accuracy and completeness of reporting of studies of diagnostic accuracy, to allow readers to assess the potential for bias in a study, and to evaluate a study's generalisability. Methods The Standards for Reporting of Diagnostic Accuracy (STARD) steering committee searched the literature to identify publications on the appropriate conduct and reporting of diagnostic studies and extracted potential items into an extensive list. Researchers, editors, and members of professional organisations shortened this list during a two day consensus meeting, with the goal of developing a checklist and a generic flow diagram for studies of diagnostic accuracy. Results The search for published guidelines about diagnostic research yielded 33 previously published checklists, from which we extracted a list of 75 potential items. At the consensus meeting, participants shortened the list to a 25 item checklist, by using evidence, whenever available. A prototype of a flow diagram provides information about the method of patient recruitment, the order of test execution, and the numbers of patients undergoing the test under evaluation and the reference standard, or both. Conclusions Evaluation of research depends on complete and accurate reporting. If medical journals adopt the STARD checklist and flow diagram, the quality of reporting of studies of diagnostic accuracy should improve to the advantage of clinicians, researchers, reviewers, journals, and the public.
Resumo:
Grass pollen is an important risk factor for allergic rhinitis and asthma in Australia and is the most prevalent pollen component of the aerospora of Brisbane, accounting for 71.6% of the annual airborne pollen load. A 5-year (June 1994-May 1999) monitoring program shows the grass pollen season to occur during the summer and autumn months (December-April), however the timing of onset and intensity of the season vary from year to year. During the pollen season, Poaceae counts exceeding 30 grains m(-3) were recorded on 244 days and coincided with maximum temperatures of 28.1 +/- 2.0degreesC. In this study, statistical associations between atmospheric grass pollen loads and several weather parameters, including maximum temperature, minimum temperature and precipitation, were investigated. Spearman's correlation analysis demonstrated that daily grass pollen counts were positively associated (P < 0.0001) with maximum and minimum temperature during each sampling year. Precipitation, although considered a less important daily factor (P < 0.05), was observed to remove pollen grains from the atmosphere during significant periods of rainfall. This study provides the first insight into the influence of meteorological variables, in particular temperature, on atmospheric Poaceae pollen counts in Brisbane. An awareness of these associations is critical for the prevention and management of allergy and asthma for atopic individuals within this region.
Resumo:
We consider the task of estimating the randomly fluctuating phase of a continuous-wave beam of light. Using the theory of quantum parameter estimation, we show that this can be done more accurately when feedback is used (adaptive phase estimation) than by any scheme not involving feedback (nonadaptive phase estimation) in which the beam is measured as it arrives at the detector. Such schemes not involving feedback include all those based on heterodyne detection or instantaneous canonical phase measurements. We also demonstrate that the superior accuracy of adaptive phase estimation is present in a regime conducive to observing it experimentally.
Resumo:
Scorpion toxins are common experimental tools for studies of biochemical and pharmacological properties of ion channels. The number of functionally annotated scorpion toxins is steadily growing, but the number of identified toxin sequences is increasing at much faster pace. With an estimated 100,000 different variants, bioinformatic analysis of scorpion toxins is becoming a necessary tool for their systematic functional analysis. Here, we report a bioinformatics-driven system involving scorpion toxin structural classification, functional annotation, database technology, sequence comparison, nearest neighbour analysis, and decision rules which produces highly accurate predictions of scorpion toxin functional properties. (c) 2005 Elsevier Inc. All rights reserved.
Resumo:
Community responses (n = 925, response rate = 71%) of a series of eight photographs of pigmented skin lesions were compared against those of general practitioners (n = 114, response rate = 77%), considered to be the most relevant gold standard. The eight photographs included three melanomas, two potentially malignant lesions and three benign pigmented lesions. Over the pool of lesions examined, the average probability that community members thought a lesion was likely to be skin cancer (0.68 [99% CI = 0.66-0.69]) was higher (p < 0.0001) than that of the comparison general practitioners 0.58 [99% CI = 0.55-0.62]. This reflects a general (but not consistent) inflated propensity to over-diagnose among community members. The average probability that respondents indicated they would seek medical advice for a lesion was 0.71 [99% CI = 0.70-0.73]. As expected, this was strongly associated with their perceptions of the skin lesion. These results suggest that the community can play a valuable role in assessing the need for medical evaluation of pigmented skin lesions. (c) 2004 International Society for Preventive Oncology. Published by Elsevier Ltd. All rights reserved.
Resumo:
The published requirements for accurate measurement of heat transfer at the interface between two bodies have been reviewed. A strategy for reliable measurement has been established, based on the depth of the temperature sensors in the medium, on the inverse method parameters and on the time response of the sensors. Sources of both deterministic and stochastic errors have been investigated and a method to evaluate them has been proposed, with the help of a normalisation technique. The key normalisation variables are the duration of the heat input and the maximum heat flux density. An example of application of this technique in the field of high pressure die casting is demonstrated. The normalisation study, coupled with previous determination of the heat input duration, makes it possible to determine the optimum location for the sensors, along with an acceptable sampling rate and the thermocouples critical response-time (as well as eventual filter characteristics). Results from the gauge are used to assess the suitability of the initial design choices. In particular the unavoidable response time of the thermocouples is estimated by comparison with the normalised simulation. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Visual acuity is limited by the size and density of the smallest retinal ganglion cells, which correspond to the midget ganglion cells in primate retina and the beta- ganglion cells in cat retina, both of which have concentric receptive fields that respond at either light- On or light- Off. In contrast, the smallest ganglion cells in the rabbit retina are the local edge detectors ( LEDs), which respond to spot illumination at both light- On and light- Off. However, the LEDs do not predominate in the rabbit retina and the question arises, what role do they play in fine spatial vision? We studied the morphology and physiology of LEDs in the isolated rabbit retina and examined how their response properties are shaped by the excitatory and inhibitory inputs. Although the LEDs comprise only similar to 15% of the ganglion cells, neighboring LEDs are separated by 30 - 40 mu m on the visual streak, which is sufficient to account for the grating acuity of the rabbit. The spatial and temporal receptive- field properties of LEDs are generated by distinct inhibitory mechanisms. The strong inhibitory surround acts presynaptically to suppress both the excitation and the inhibition elicited by center stimulation. The temporal properties, characterized by sluggish onset, sustained firing, and low bandwidth, are mediated by the temporal properties of the bipolar cells and by postsynaptic interactions between the excitatory and inhibitory inputs. We propose that the LEDs signal fine spatial detail during visual fixation, when high temporal frequencies are minimal.
Resumo:
Background and Objective: To describe the diagnostic accuracy and practical application of the Peter James Centre Falls Risk Assessment Tool (PJC-FRAT), a multidisciplinary falls risk screening and intervention deployment instrument. Methods: In phase 1, the accuracy of the PJC-FRAT was prospectively compared to a gold standard (the STRATIFY) on a cohort of subacute hospital patients (n = 122). In phase 2, the PJC-FRAT was temporally reassessed using a subsequent cohort (n = 316), with results compared to those of phase 1. Primary outcomes were falls (events), fallers (patients who fell), and hospital completion rates of the PJC-FRAT. Results: In phase 1, PJC-FRAT accuracy of identifying falters showed sensitivity of 73% (bootstrap 95% confidence interval CI = 55, 90) and specificity of 75% (95% CI = 66, 83), compared with the STRATIFY (cutoff >= 2/5) sensitivity of 77% (95% CI = 59, 92) and specificity of 51% (95% CI = 41, 61). This difference was not significant. In phase 2, accuracy of nursing staff using the PJC-FRAT was lower. PJC-FRAT completion rates varied among disciplines over both phases: nurses and physiotherapists, >= 90%; occupational therapists, >= 82%; and medical officers, >= 57%. Conclusion: The PJC-FRAT was practical and relatively accurate as a predictor of falls and a deployment instrument for falls prevention interventions, although continued staff education may be necessary to maintain its accuracy. (c) 2006 Elsevier Inc. All rights reserved.