51 resultados para Volume Residual


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Guidelines recommend neonatal resuscitation without controlling tidal volume or positive end-expiratory pressure (PEEP). However, these may improve gas exchange, lung volume and outcome. Aim: To investigate resuscitation of very premature lambs with a Laerdal bag without PEEP versus volume guarantee ventilation with PEEP. Methods: Anaesthetized lambs (n = 20) delivered at 125 d gestation were randomized to three groups receiving 15 min resuscitation: (1) Laerdal bag and no PEEP; (2) ventilation with a tidal volume of 5 ml/kg and 8 cm H2O PEEP; (3) ventilation with 10 ml/kg and 8 cm H2O PEEP. They were then all ventilated for 2 h with tidal volumes of 5 or 10 ml/kg, and 8 cm H2O PEEP. Ventilation parameters and blood gases were recorded. Results: Different tidal volumes affected PaCO2 within minutes, with 10 ml/kg causing severe hypocarbia. PEEP had little effect on PaCO2. Oxygenation improved significantly with PEEP of 8 cm H2O, irrespective of tidal volume. Conclusion: Very premature lambs can be resuscitated effectively using volume-guarantee ventilation and PEEP. Tidal volumes affected PaCO2 within minutes but had little effect on oxygenation. PEEP halved the oxygen requirement compared with no PEEP. Resuscitating premature babies with controlled tidal volumes and PEEP might improve their outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Caudal block results in a motor blockade that can reduce abdominal wall tension. This could interact with the balance between chest wall and lung recoil pressure and tension of the diaphragm, which determines the static resting volume of the lung. On this rationale, we hypothesised that caudal block causes an increase in functional residual capacity and ventilation distribution in anaesthetised children. Fifty-two healthy children (15-30 kg, 3-8 years of age) undergoing elective surgery with general anaesthesia and caudal block were studied and randomly allocated to two groups: caudal block or control. Following induction of anaesthesia, the first measurement was obtained in the supine position (baseline). All children were then turned to the left lateral position and patients in the caudal block group received a caudal block with bupivacaine. No intervention took place in the control group. After 15 nun in the supine position, the second assessment was performed. Functional residual capacity and parameters of ventilation distribution were calculated by a blinded reviewer. Functional residual capacity was similar at baseline in both groups. In the caudal block group, the capacity increased significantly (p < 0.0001) following caudal block, while in the control group, it remained unchanged. In both groups, parameters of ventilation distribution were consistent with the changes in functional residual capacity. Caudal block resulted in a significant increase in functional residual capacity and improvement in ventilation homogeneity in comparison with the control group. This indicates that caudal block might have a beneficial effect on gas exchange in anaesthetised, spontaneously breathing preschool-aged children with healthy lungs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to explore the potential advantages, both theoretical and applied, of preserving low-frequency acoustic hearing in cochlear implant patients. Several hypotheses are presented that predict that residual low-frequency acoustic hearing along with electric stimulation for high frequencies will provide an advantage over traditional long-electrode cochlear implants for the recognition of speech in competing backgrounds. A simulation experiment in normal-hearing subjects demonstrated a clear advantage for preserving low-frequency residual acoustic hearing for speech recognition in a background of other talkers, but not in steady noise. Three subjects with an implanted "short-electrode" cochlear implant and preserved low-frequency acoustic hearing were also tested on speech recognition in the same competing backgrounds and compared to a larger group of traditional cochlear implant users. Each of the three short-electrode subjects performed better than any of the traditional long-electrode implant subjects for speech recognition in a background of other talkers, but not in steady noise, in general agreement with the simulation studies. When compared to a subgroup of traditional implant users matched according to speech recognition ability in quiet, the short-electrode patients showed a 9-dB advantage in the multitalker background. These experiments provide strong preliminary support for retaining residual low-frequency acoustic hearing in cochlear implant patients. The results are consistent with the idea that better perception of voice pitch, which can aid in separating voices in a background of other talkers, was responsible for this advantage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The artificial dissipation effects in some solutions obtained with a Navier-Stokes flow solver are demonstrated. The solvers were used to calculate the flow of an artificially dissipative fluid, which is a fluid having dissipative properties which arise entirely from the solution method itself. This was done by setting the viscosity and heat conduction coefficients in the Navier-Stokes solvers to zero everywhere inside the flow, while at the same time applying the usual no-slip and thermal conducting boundary conditions at solid boundaries. An artificially dissipative flow solution is found where the dissipation depends entirely on the solver itself. If the difference between the solutions obtained with the viscosity and thermal conductivity set to zero and their correct values is small, it is clear that the artificial dissipation is dominating and the solutions are unreliable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A copolymer of X-hydroxyethyl methacrylate (HEMA) with 2-ethoxy ethyl methacrylate (EEMA) was synthesized and the molecular mobility, free volume, and density properties examined as a function of composition. These properties were correlated with the equilibrium water uptake in order to determine which of the properties were most influential in causing high water sorption, as these materials are suitable candidates for hydrogel systems. It was found that the polar HEMA repeat unit results in a rigid, glassy sample at room temperature due to the high degree of hydrogen bonding between chains whereas high EEMA content leads to rubbery samples with subambient glass transition temperatures. The free volume properties on the molecular scale measured by positron annihilation Lifetime spectroscopy (PALS) showed that higher HEMA content led to smaller, fewer holes and a lower free volume fraction than EEMA. Therefore the high water uptake of HEEMA-containing copolymers is largely related to the high polarity of the HEMA unit compared to EEMA, despite the low content of free volume into which the water can initially diffuse. Trends in density with copolymer composition, as measured on a macroscopic level, differs to that seen by PALS and indicates that the two techniques are measuring different scales of packing. (C) 1998 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plant cells are characterized by low water content, so the fraction of cell volume (volume fraction) in a vessel is large compared with other cell systems, even if the cell concentrations are the same. Therefore, concentration of plant cells should preferably be expressed by the liquid volume basis rather than by the total vessel volume basis. In this paper, a new model is proposed to analyze behavior of a plant cell culture by dividing the cell suspension into the biotic- and abiotic-phases, Using this model, we analyzed the cell-growth and the alkaloid production by Catharanthus roseus, Large errors in the simulated results were observed if the phase-segregation was not considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since February 1996 we have prospectively assessed residual adrenal autonomy by the fludrocortisone suppression test (FST) in 23 patients 3 months after unilateral adrenalectomy for Conn syndrome and in 45 patients after a longer interval. In regard to blood pressure, 36 (53%) patients were cured of hypertension and the remaining 32 (47%) patients had improved hypertension control at the time of their latest postoperative clinical assessment. In regard to the outcome of surgery, patients who achieved normal suppressibility of aldosterone were regarded as cured, and those who had greater suppressibility after surgery were considered improved. Time since surgery for the whole group averaged 26 months. By these biochemical criteria, 42 patients (62%) were cured by surgery, and the rest improved; 16 (76%) of 21 women were cured, and 26 (55%) of 47 men. The women (mean +/- SD age 47 +/- 11 years) were significantly (p < 0.05) younger than the men (52 +/- 9 Sears). Preoperative aldosterone levels before and after FST were similar in the cured and improved groups and fell significantly (p < 0.01) in both groups following surgery. After surgical reduction of autonomous aldosterone production, mean plasma renin activity levels increased sixfold in the cured group and threefold in the improved group. Surgical mortality in this group of 68 patients with Conn syndrome was zero.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) was used to evaluate and compare with anthropometry a fundamental bioelectrical impedance analysis (BIA) method for predicting muscle and adipose tissue composition in the lower limb. Healthy volunteers (eight men and eight women), aged 41 to 62 years, with mean (S.D.) body mass indices of 28.6 (5.4) kg/m(2) and 25.1 (5.4) kg/m(2) respectively, were subjected to MRI leg scans, from which 20-cm sections of thigh and IO-cm sections of lower leg (calf) were analysed for muscle and adipose tissue content, using specifically developed software. Muscle and adipose tissue were also predicted from anthropometric measurements of circumferences and skinfold thicknesses, and by use of fundamental BIA equations involving section impedance at 50 kHz and tissue-specific resistivities. Anthropometric assessments of circumferences, cross-sectional areas and volumes for total constituent tissues matched closely MRI estimates. Muscle volume was substantially overestimated (bias: thigh, -40%; calf, -18%) and adipose tissue underestimated (bias: thigh, 43%; calf, 8%) by anthropometry, in contrast to generally better predictions by the fundamental BIA approach for muscle (bias:thigh, -12%; calf, 5%) and adipose tissue (bias:thigh, 17%; calf, -28%). However, both methods demonstrated considerable individual variability (95% limits of agreement 20-77%). In general, there was similar reproducibility for anthropometric and fundamental BIA methods in the thigh (inter-observer residual coefficient of variation for muscle 3.5% versus 3.8%), but the latter was better in the calf (inter-observer residual coefficient of variation for muscle 8.2% versus 4.5%). This study suggests that the fundamental BIA method has advantages over anthropometry for measuring lower limb tissue composition in healthy individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioelectrical impedance analysis (BIA) has been reported to be insensitive to changes in water volumes in individual subjects, This study was designed to investigate the effect on the intra- and extracellular resistances (Ri and Re) of the segments of subjects for whom body water was changed without significant change to the total amount of electrolyte in the respective fluids, Twelve healthy adult subjects were recruited. Ri and Re of the leg, trunk, and arm of the subjects were determined from BIA measures prior to commencement of two separate studies that involved intervention, resulting in a loss/gain of body water effected either bt a sauna followed by water intake (study 1) or by ingestion (study 2). Ri and Re of the segments were also determined at a number of times following these interventions, The mean change in body water, expressed as a percentage of body weight, was 0.9% in study 1 and 1.25% in study 2. For each study, the results for each subject were normalized for each limb to the initial (prestudy) value and then the normalized results for each segment were pooled for all subjects, ANOVA of these pooled results failed to demonstrate any significant differences between the normalized mean values of Ri or Re of the segments measured through the course of each study, The failure to detect a change in Ri or Re is explained in terms of the basic theory of BIA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

I noted with interest the article by Drs Perrin and Guex, entitled &dquo;Edema and leg volume: Methods of assessment,&dquo; published in Angiology 51:9-12, 2000. This was a timely and comprehensive review of the various methods in clinical use for the assessment of peripheral edema, notably in the leg. I would like to take this opportunity to alert readers to a further technique useful for this purpose, namely, bioelectrical impedance analysis. An early reportl described its use for the measurement of edema in the leg, but other than its successful use for the assessment of edema in the arm following masteCtoMy,2,1 the potential of the method remains to be fully realized. This is unfortunate since the method directly and quantifiably measures edema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The volume of the extracellular compartment (tubular system) within intact muscle fibres from cane toad and rat was measured under various conditions using confocal microscopy. Under physiological conditions at rest, the fractional volume of the tubular system (t-sys(Vol)) was 1.38 +/- 0.09% (n = 17),1.41 +/- 0.09% (n = 12) and 0.83 +/- 0.07% (n = 12) of the total fibre volume in the twitch fibres from toad iliofibularis muscle, rat extensor digitorum longus muscle and rat soleus muscle, respectively. In toad muscle fibres, the t-sys(Vol) decreased by 30% when the tubular system was fully depolarized and decreased by 15% when membrane cholesterol was depleted from the tubular system with methyl-beta-cyclodextrin but did not change as the sarcomere length was changed from 1.93 to 3.30 mum. There was also an increase by 30% and a decrease by 25% in t-sys(Vol) when toad fibres were equilibrated in solutions that were 2.5-fold hypertonic and 50% hypotonic, respectively. When the changes in total fibre volume were taken into consideration, the t-sys(Vol) expressed as a percentage of the isotonic fibre volume did actually decrease as tonicity increased, revealing that the tubular system in intact fibres cannot be compressed below 0.9% of the isotonic fibre volume. The results can be explained in terms of forces acting at the level of the tubular wall. These observations have important physiological implications showing that the tubular system is a dynamic membrane structure capable of changing its volume in response to the membrane potential, cholesterol depletion and osmotic stress but not when the sarcomere length is changed in resting muscle.