30 resultados para Transit time
Resumo:
Study objectives: Currently, esophageal pressure monitoring is the "gold standard" measure for inspiratory efforts, hut its invasive nature necessitates a better tolerated and noninvasive method to be used on children. Pulse transit time (PTT) has demonstrated its potential as a noninvasive surrogate marker for inspiratory efforts. The principle velocity determinant of PTT is the change in stiffness of the arterial wall and is inversely correlated to BP. Moreover, PTT has been shown to identify changes in inspiratory effort via the BP fluctuations induced by negative pleural pressure swings. In this study, the capability of PTT to classify respiratory, events during sleep as either central or obstructive in nature was investigated. Setting and participants: PTT measure was used in adjunct to routine overnight polysomnographic studies performed on 33 children (26 boys and 7 girls; mean +/- SD age, 6.7 +/- 3.9 years). The accuracy of PTT measurements was then evaluated against scored corresponding respiratory events in the polysomnography recordings. Results: Three hundred thirty-four valid respiratory events occurred and were analyzed. One hundred twelve obstructive events (OEs) showed a decrease in mean PTT over a 10-sample window that had a probability of being correctly ranked below the baseline PTT during tidal breathing of 0.92 (p < 0.005); 222 central events (CEs) showed a decrease in the variance of PTT over a 10-sample window that had a probability of being ranked below the baseline PTT of 0.94 (p < 0.005). This indicates that, at a sensitivity of 0.90, OEs can be detected with a specificity of 0.82 and CEs can be detected with a specificity of 0.80. Conclusions: PTT is able to categorize CEs and OEs accordingly in the absence of motion artifacts, including hypopneas. Hence, PTT shows promise to differentiate respiratory, events accordingly and can be an important diagnostic tool in pediatric respiratory sleep studies.< 0.005); 222 central events (CEs) showed a decrease in the variance of PTT over a 10-sample window that had a probability of being ranked below the baseline PTT of 0.94 (p < 0.005). This indicates that, at a sensitivity of 0.90, OEs can be detected with a specificity of 0.82 and CEs can be detected with a specificity of 0.80. Conclusions: PTT is able to categorize CEs and OEs accordingly in the absence of motion artifacts, including hypopneas. Hence, PTT shows promise to differentiate respiratory, events accordingly and can be an important diagnostic tool in pediatric respiratory sleep studies.');"
Resumo:
Changes in arterial distensibility have been widely used to identify the presence of cardiovascular abnormalities like hypertension. Pulse wave velocity (PWV) has shown to be related to arterial distensibility. However, the lack of suitable techniques to measure PWV nonintrusively has impeded its clinical usefulness. Pulse transit time (PTT) is a noninvasive technique derived from the principle of PWV. PTT has shown its capabilities in cardiovascular and cardiorespiratory studies in adults. However, no known study has been conducted to understand the suitability and utility of PTT to estimate PWV in children. Two computational methods to derive PWV from PTT values obtained from 23 normotensive Caucasian children (19 males, aged 5-12 years old) from their finger and toe were conducted. Furthermore, the effects of adopting different postures on the PWV derivations were investigated. Statistical analyses were performed in comparison with two previous PWV studies conducted on children. Results revealed that PWV derived from the upper limb correlated significantly (P
Resumo:
Pulse transit time (PTT) is a non-invasive measure of arterial compliance. It can be used to assess instantaneous blood pressure (BP) changes in continual cardiovascular measurement such as during overnight respiratory sleep studies. In these studies, periodic changes in limb position can occur randomly. However, little is known about their possible effects on PTT monitored on the various limbs. The objective of this study was to evaluate PTT differences on all four limbs during two positional changes (lowering and raising of a limb). Ten healthy adults (seven male) with a mean age of 27.0 years were recruited in this study. The results showed that the limb that underwent a positional change had significant (p < 0.05) local PTT differences when compared to its nominal baseline value, whereas PTT changes in the other remaining limbs were insignificant (p > 0.05). The mean PTT value measured from a vertically-raised limb increased by 42.7 ms, while it decreased by 28.1 ms with a half-lowered limb. The PTT differences observed during positional change can be contributed to by the complex interactions between hydrostatic pressure changes, autonomic and local autoregulation experienced in these limbs. Hence the findings herein suggest that PTT is able to reflect local circulatory responses despite changes in the position of other limbs. This can be useful in prolonged clinical observations where limb movements are expected.
Resumo:
Conventional overnight polysomnography (PSG) used to determine the respiratory behaviour during sleep can be a complex and expensive procedure. Pulse transit time analysis (PTT) has shown potential to detect obstructive apnoeic and hypopnoeic events in adults. This study was undertaken to determine the potential of PTT to differentiate responses to upper airway obstruction. 103 obstructive respiratory events occurred in PSG studies performed on 11 children (10 male and 1 female, mean age 7.5years). PTT measurements were evaluated against the corresponding PSG results pre-scored by 2 blinded observers. Broadly, there were 2 types of responses. They can be either short period of rapid PTT decreases (Type 1) or prolonged but gradual PTT decreases (Type 2). Type 1 obstructive events showed a mean change of 51.77% (p
Resumo:
Pulse Transit Time (PTT) measurement has showed potential in non-invasive monitoring of changes in blood pressure. In children, the common peripheral sites used for these studies are a finger or toe. Presently, there are no known studies conducted to investigate any possible physiologic parameters affecting PTT measurement at these sites for children. In this study, PTT values of both peripheral sites were recorded from 64 children in their sitting posture. Their mean age with standard deviation (SD) was 8.2 2.6years (ranged 3 to 12years). Subjects' peripheries path length, heart rate (HR), systolic (SBP) and diastolic blood pressure (DBP) were measured to investigate any contributions to PTT measurement. The peripheral pulse timing characteristic measured by photoplethysmography (PPG) shows a 59.5 8.5ms (or 24.8 0.4%) difference between the two peripheries (p