32 resultados para Therapeutic drug monitoring


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to determine the most informative sampling time(s) providing a precise prediction of tacrolimus area under the concentration-time curve (AUC). Fifty-four concentration-time profiles of tacrolimus from 31 adult liver transplant recipients were analyzed. Each profile contained 5 tacrolimus whole-blood concentrations (predose and 1, 2, 4, and 6 or 8 hours postdose), measured using liquid chromatography-tandem mass spectrometry. The concentration at 6 hours was interpolated for each profile, and 54 values of AUC(0-6) were calculated using the trapezoidal rule. The best sampling times were then determined using limited sampling strategies and sensitivity analysis. Linear mixed-effects modeling was performed to estimate regression coefficients of equations incorporating each concentration-time point (C0, C1, C2, C4, interpolated C5, and interpolated C6) as a predictor of AUC(0-6). Predictive performance was evaluated by assessment of the mean error (ME) and root mean square error (RMSE). Limited sampling strategy (LSS) equations with C2, C4, and C5 provided similar results for prediction of AUC(0-6) (R-2 = 0.869, 0.844, and 0.832, respectively). These 3 time points were superior to C0 in the prediction of AUC. The ME was similar for all time points; the RMSE was smallest for C2, C4, and C5. The highest sensitivity index was determined to be 4.9 hours postdose at steady state, suggesting that this time point provides the most information about the AUC(0-12). The results from limited sampling strategies and sensitivity analysis supported the use of a single blood sample at 5 hours postdose as a predictor of both AUC(0-6) and AUC(0-12). A jackknife procedure was used to evaluate the predictive performance of the model, and this demonstrated that collecting a sample at 5 hours after dosing could be considered as the optimal sampling time for predicting AUC(0-6).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Renal transplant recipients were noted to appear cushingoid while on low doses of steroid as part of a triple therapy immunosuppression of cyclosporin A (CsA), prednisolone, and azathioprine. Methods: The study group comprised adult renal transplant recipients with stable graft function who had received their renal allograft a minimum of 1 year previously (43 studies undertaken in 22 men and 20 women) with median daily prednisone dose of 7 mg (range 3-10). The control group was healthy nontransplant subjects [median dose 10 mg (10-30)]. Prednisolone bioavailability was measured using a limited 6-hour area under the curve (AUC), with prednisolone measured using specific HPLC assay. Results: The median prednisolone AUC/mg dose for all transplant recipients was significantly greater than the control group by approximately 50% (316 nmol(.)h/L/mg prednisolone versus 218). AUC was significantly higher in female recipients (median 415 versus 297 for men) and in recipients receiving cyclospotin (348 versus 285). The highest AUC was in women on estrogen supplements who were receiving cyclosporin (median 595). A significantly higher proportion of patients on triple therapy had steroid side effects compared with those on steroid and azathioprine (17/27 versus 4/15), more women than men had side effects (14/16 versus 7/22), and the AUC/mg prednisone was greater in those with side effects than without (median 377 versus 288 nmol-h/L/mg). Discussion: The results are consistent with the hypothesis that CsA increases the bioavailability of prednisolone, most likely through inhibition of beta-glycoprotein. The increased exposure to steroid increased the side-effect profile of steroids in the majority of patients. Because the major contributor to AUC is the maximum postdose concentration, it may be possible to use single-point monitoring (2 hours postdose) for routine clinical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Cyclosporin is an immunosuppressant drug with a narrow therapeutic window. Trough and 2-h post-dose blood samples are currently used for therapeutic drug monitoring in solid organ transplant recipients. The aim of the current study was to develop a rapid HPLC-tandem mass spectrometry (HPLC-MS) method for the measurement of cyclosporin in whole blood that was not only suitable for the clinical setting but also considered a reference method. Methods: Blood samples (50 mu L) were prepared by protein precipitation followed by C-18 solid-phase extraction while using d(12) cyclosporin as the internal standard. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface in positive ionization mode. Results: The assay was linear from 10 to 2000 mu g/L (r(2) > 0.996, n = 9). Inter-day,analytical recovery and imprecision using whole blood quality control samples at 10, 30, 400, 1500, and 2000 mu g/L were 94.9-103.5% and

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lamotrigine concentrations were measured simultaneously (as far as was feasible) in stimulated and unstimulated saliva samples, and in plasma, from seven adult volunteers over a 32 h period following a single 50 mg dose of the drug, and in 20 children and adolescents during the course of routine antiepileptic therapy. In individuals there was a close correlation between the measurements at least 2 It after ingestion of the drug. Concentrations in stimulated and unstimulated saliva were similar; the stimulation produced little change in the saliva secretion rate. The saliva-to-plasma concentration ratio increased linearly by 0.78% for each 1 mg/L plasma lamotrigine concentration, with a mean value of 48.8% at a plasma lamotrigine concentration of 10 mg/L. With appropriate precautions as to the timing of saliva collections, and a single plasma lamotrigine concentration measurement to calibrate the salivary values in the individual, salivary lamotrigine concentration measurement appears to be a practicable approach to therapeutic drug monitoring. This has significant implications for the elucidation of the pharmacokinetics of lamotrigine in the paediatric population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this review is to analyse critically the recent literature on the clinical pharmacokinetics and pharmacodynamics of tacrolimus in solid organ transplant recipients. Dosage and target concentration recommendations for tacrolimus vary from centre to centre, and large pharmacokinetic variability makes it difficult to predict what concentration will be achieved with a particular dose or dosage change. Therapeutic ranges have not been based on statistical approaches. The majority of pharmacokinetic studies have involved intense blood sampling in small homogeneous groups in the immediate post-transplant period. Most have used nonspecific immunoassays and provide little information on pharmacokinetic variability. Demographic investigations seeking correlations between pharmacokinetic parameters and patient factors have generally looked at one covariate at a time and have involved small patient numbers. Factors reported to influence the pharmacokinetics of tacrolimus include the patient group studied, hepatic dysfunction, hepatitis C status, time after transplantation, patient age, donor liver characteristics, recipient race, haematocrit and albumin concentrations, diurnal rhythm, food administration, corticosteroid dosage, diarrhoea and cytochrome P450 (CYP) isoenzyme and P-glycoprotein expression. Population analyses are adding to our understanding of the pharmacokinetics of tacrolimus, but such investigations are still in their infancy. A significant proportion of model variability remains unexplained. Population modelling and Bayesian forecasting may be improved if CYP isoenzymes and/or P-glycoprotein expression could be considered as covariates. Reports have been conflicting as to whether low tacrolimus trough concentrations are related to rejection. Several studies have demonstrated a correlation between high trough concentrations and toxicity, particularly nephrotoxicity. The best predictor of pharmacological effect may be drug concentrations in the transplanted organ itself. Researchers have started to question current reliance on trough measurement during therapeutic drug monitoring, with instances of toxicity and rejection occurring when trough concentrations are within 'acceptable' ranges. The correlation between blood concentration and drug exposure can be improved by use of non-trough timepoints. However, controversy exists as to whether this will provide any great benefit, given the added complexity in monitoring. Investigators are now attempting to quantify the pharmacological effects of tacrolimus on immune cells through assays that measure in vivo calcineurin inhibition and markers of immuno suppression such as cytokine concentration. To date, no studies have correlated pharmacodynamic marker assay results with immunosuppressive efficacy, as determined by allograft outcome, or investigated the relationship between calcineurin inhibition and drug adverse effects. Little is known about the magnitude of the pharmacodynamic variability of tacrolimus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current approach for therapeutic drug monitoring in renal transplant recipients receiving mycophenolate mofetil (MMF) is measurement of total mycophenolic acid (MPA) concentration. Because MPA is highly bound, during hypoalbuminemia the total concentration no longer reflects the free (pharmacologically active) concentration. The authors investigated what degree of hypoalbuminemia causes a significant change in protein binding and thus percentage free MPA. Forty-two renal transplant recipients were recruited for the study. Free and total concentrations of MPA (predose, and 1, 3, and 6 hours post-MMF dose samples) and plasma albumin concentrations were determined on day 5 posttransplantation. Six-hour area under the concentration-time curve (AUC(0-6)) values were calculated for free and total MPA, and percentage free MPA was determined for each patient. The authors found a significant relationship between low albumin concentrations and increased percentage free MPA (Spearman correlation = -0.54, P < 0.0001). Receiver operating characteristic (ROC) curve analysis was performed on the albumin versus percentage free MPA data. The cutoff value of albumin determined from the ROC analysis that differentiated normal from elevated percentage free MPA (defined as greater than or equal to3%) in this patient population was 31 g/L. At this cutoff value albumin was found to be a good predictor of altered free MPA percentage, with a sensitivity and specificity of 0.75 and 0.80, respectively, and an area under the ROC curve of 0.79. To rationalize MMF dosing regimens in hypoalbuminemic patients (plasma albumin less than or equal to 31 g/L), clinicians should consider monitoring the free MPA concentration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The role of the therapeutic drug monitoring laboratory in support of immunosuppressant drug therapy is well established, and the introduction of sirolimus (SRL) is a new direction in this field. The lack of an immunoassay for several years has restricted the availability of SRL assay services. The recent availability of a CEDIA (R) SRL assay has the potential to improve this situation. The present communication has compared the CEDIA (R) SRL method with 2 established chromatographic methods, HPLC-UV and HPLC-MS/MS. The CEDIA (R) method, run on a Hitachi 917 analyzer, showed acceptable validation criteria with within-assay precision of 9.1% and 3.3%, and bias of 17.1% and 5.8%, at SRL concentrations of 5.0 mu g/L and 20 mu g/L, respectively. The corresponding between-run precision values were 11.5% and 3.3% and bias of 7.1% and 2.9% at 5.0 mu g/L and 20 mu g/L, respectively, The lower limit of quantification was found to be 3.0 mu g/L. A series of 96 EDTA whole-blood samples predominantly from renal transplant recipients were assayed by the 3 methods for comparison. It was found that the CEDIA (R) method showed a Deming regression line of CEDIA = 1.20 X HPLC-MS/MS - 0.07 (r = 0.934, SEE = 1.47), with a mean bias of 20.4%. Serial blood samples from 8 patients included in this evaluation showed that the CEDIA (R) method reflected the clinical fluctuations in the chromatographic methods, albeit with the variable bias noted. The CEDIA (R) method on the H917 analyzer is therefore a useful adjunct to SRL dosage individualization in renal transplant recipients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We observed unexpected high plasma concentrations of tobrarriycin (48.5 and 28.1 mg/L) in fingerprick blood samples after the nebulization of tobramycin solution for inhalation (tobramycin 300 mg/5 mL, TOBI(R)) by 2 young children aged 3 years. To investigate whether dermal contamination could be the source of error, 3 adult volunteers were present during another nebulization by a third child (age 2 years). The volunteers had exposure to tobramycin by handling the nebulizer or the nebule and also by inhalation from holding the child and being in close proximity while TOBI(R) was being administered. Five blood samples by fingerprick and 2 by venipuncture were collected and assayed for tobramycin concentration. On each occasion the site was swabbed with alcohol wipes to mimic standard patient sampling methods. One site was resampled after cleaning of hands with 2% chlorhexidine gluconate and water. Tobramycin concentrations from venipuncture 1-2 hours after nebulization were all < 0.2 mg/L except for 1 result of 1.2 mg/L. The tobramycin concentrations from fingerpricks before hand washing varied between 6.8 and 172 mg/L, and after hand washing between 0.3 and 17.6 mg/L. Contamination of fingers with tobramycin is likely to have caused the error in the 2 initial cases and did cause misleadingly elevated levels in the adult volunteers. We caution that therapeutic drug monitoring of nebulized tobramycin should not be done by fingerprick sampling, and care should be taken to avoid contamination of the venipuncture site.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The pharmacokinetic disposition of metformin in late pregnancy was studied together with the level of fetal exposure at birth. Blood samples were obtained in the third trimester of pregnancy from women with gestational diabetes or type 2 diabetes, 5 had a previous diagnosis of polycystic ovary syndrome. A cord blood sample also was obtained at the delivery of some of these women, and also at delivery of others who had been taking metformin during pregnancy but from whom no blood had been taken. Plasma metformin concentrations were assayed by a new, validated, reverse-phase HPLC method, A 2-compartment, extravascular maternal model with transplacental partitioning of drug to a fetal compartment was fitted to the data. Nonlinear mixed-effects modeling was performed in'NONMEM using FOCE with INTERACTION. Variability was estimated using logarithmic interindividual and additive residual variance models; the covariance between clearance and volume was modeled simultaneously. Mean (range) metformin concentrations in cord plasma and in maternal plasma were 0.81 (range, 0.1-2.6) mg/L and 1.2 (range, 0. 1-2.9) mg/L, respectively. Typical population values (interindividual variability, CV%) for allometrically scaled maternal clearance and volume of distribution were 28 L/h/70 kg (17.1%) and 190 L/70 ka (46.3%), giving a derived population-wide half-life of 5.1 hours. The placental partition coefficient for metformin was 1.07 (36.3%). Neither maternal age nor weight significantly influenced the pharmacokinetics. The variability (SD) of observed concentrations about model-predicted concentrations was 0.32 mg/L. The pharmacokinetics were similar to those in nonpregnant patients and, therefore, no dosage adjustment is warranted. Metformin readily crosses the placenta, exposing the fetus to concentrations approaching those in the maternal circulation. The sequelae to such exposure, ea, effects on neonatal obesity and insulin resistance, remain unknown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Therapeutic monitoring with dosage individualization of sirolimus drug therapy is standard clinical practice for organ transplant recipients. For several years sirolimus monitoring has been restricted as a result of lack of an immunoassay. The recent reintroduction of the microparticle enzyme immunoassay (MEIA (R)) for sirolimus on the IMx (R) analyser has the potential to address this situation. This Study, using patient samples, has compared the MEIA (R) sirolimus method with an established HPLC-tandem mass spectrometry method (HPLC-MS/MS). An established HPLC-UV assay was used for independent cross-validation. For quality control materials (5, 11, 22 mu g/L), the MEIA (R) showed acceptable validation criteria based on intra-and inter-run precision (CV) and accuracy (bias) of < 8% and < 13%, respectively. The lower limit of quantitation was found to be approximately 3 mu g/L. The performance of the immunoassay was compared with HPLC-MS/MS using EDTA whole-blood samples obtained from various types of organ transplant recipients (n = 116). The resultant Deming regression line was: MEIA = 1.3 x HPLC-MS/MS+ 1.3 (r = 0.967, s(y/x) = 1) with a mean bias of 49.2% +/- 23.1 % (range, -2.4% to 128%; P < 0.001). The reason for the large and variable bias was not explored in this study, but the sirolimus-metabolite cross-reactivity with the MEIA (R) antibody could be a substantive contributing factor. Whereas the MEIA (R) sirolimus method may be an adjunct to sirolimus dosage individualization in transplant recipients, users must consider the implications of the substantial and variable bias when interpreting results. In selected patients where difficult clinical issues arise, reference to a specific chromatographic method may be required.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper examines population trends in morphine prescriptions in Australia, and contrasts them with findings from annual surveys with regular injecting drug users (IDU). Data on morphine prescriptions from 1995 to 2003 were obtained from the Drug Monitoring System (DRUMS) run by the Australian Government Department of Health and Ageing. Data collected from regular IDU as part of the Australian Illicit Drug Reporting System (IDRS) were analysed (2001-2004). The rate of morphine prescription per person aged 15-54 years increased by 89% across Australia between 1995 and 2003 (from 46.3 to 85.9 mg per person). Almost half (46%) of IDU surveyed in 2004 reported illicit morphine use, with the highest rates in jurisdictions where heroin was less available. Recent morphine injectors were significantly more likely to be male, unemployed, out of treatment and homeless in comparison to IDU who had not injected morphine. They were also more likely to have injected other pharmaceutical drugs and to report injection related problems. Among those who had injected morphine recently, the most commonly reported injecting harms were morphine dependence (38%), difficulty finding veins into which to inject (36%) and scarring or bruising (27%). Morphine use and injection is a common practice among regular IDU in Australia. In some cases, morphine may be a substitute for illicit heroin; in others, it may be being used to treat heroin dependence where other pharmacotherapies, such as methadone and buprenorphine, are perceived as being unavailable or undesirable by IDU. Morphine injection appears to be associated with polydrug use, and with it, a range of problems related to drug injection. Further research is required to monitor and reduce morphine diversion and related harms by such polydrug injectors.