57 resultados para Pet-Vet


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We used positron emission tomography (PET) with O-15-labelled water to record patterns of cerebral activation in six patients with Parkinson's disease (PD), studied when clinically off and after turning on as a result of dopaminergic stimulation. They were asked to imagine a Finger opposition movement performed with their right hand. externally paced at a rate of 1 Hz. Trials alternating between motor imagery and rest were measured. A pilot study of three age-matched controls was also performed. We chose the task as a robust method of activating the supplementary motor area (SMA), defects of which have been reported in PD. The PD patients showed normal de-rees of activation of the SMA (proper) when both off and on. Significant activation with imagining movement also occurred in the ipsilateral inferior parietal cortex (both off and when on) and ipsilateral premotor cortex (when off only). The patients showed significantly greater activation of the rostral anterior cingulate and significantly less activation of the left lingual gyrus and precuneus when performing the task on compared with their performance when off. PD patients when imagining movement and off showed less activation of several sites including the right dorsolateral prefrontal cortex (DLPFC) when compared to the controls performing the same task. No significant differences from controls were present when the patients imagined when on. Our results are consistent with other studies showing deficits of pre-SMA function in PD with preserved function of the SMA proper. In addition to the areas of reduced activation (anterior cingulate, DLPFC), there were also sites of activation (ipsilateral premotor and inferior parietal cortex) previously reported as locations of compensatory overactivity for PD patients performing similar tasks. Both failure of activation and compensatory changes a-re likely to contribute to the motor deficit in PD. (C) 2001 Movement Disorder Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature examining purported relationships between ownership of companion animals and health is extremely heterogeneous. While much of the descriptive literature tends to support benefits of animal companionship, large scale, controlled research yields inconsistent and even contradictory findings on several issues, including associations with cardiovascular disease, mood and wellbeing. In an analysis of a large longitudinal data-set from the Australian Longitudinal Study on Women's Health, a prospective study of a nationally representative sample of more than 12,000 older women, difficulties with disentangling the effects of powerful demographic variables and age-related factors from the specific effects of pet ownership became apparent. Both cross-sectional and longitudinal analyses demonstrated that associations between mental and physical health and pet ownership as well as changes in pet ownership over time were weak and inconsistent compared to the large effects of living arrangements and other demographic variables. As sociodemographic variables relate strongly to both health and opportunities for pet ownership, this high level of confounding means it is unlikely that the impact of the specific variable of pet ownership on health can be ascertained from such studies. Rather, well-designed experimental studies, wherein the majority of such confounding variables can be held constant or at least somewhat controlled, are needed.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a model for permeation in oxide coated gas barrier films. The model accounts for diffusion through the amorphous oxide lattice, nano-defects within the lattice, and macro-defects. The presence of nano-defects indicate the oxide layer is more similar to a nano-porous solid (such as zeolite) than silica glass with respect to permeation properties. This explains why the permeability of oxide coated polymers is much greater, and the activation energy of permeation much lower, than values expected for polymers coated with glass. We have used the model to interpret permeability and activation energies measured for the inert gases (He, Ne and Ar) in evaporated SiOx films of varying thickness (13-70 nm) coated on a polymer substrate. Atomic force and scanning electron microscopy were used to study the structure of the oxide layer. Although no defects could be detected by microscopy, the permeation data indicate that macro-defects (>1 nm), nano-defects (0.3-0.4 nm) and the lattice interstices (<0.3 nm) all contribute to the total permeation. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today, the standard approach for the kinetic analysis of dynamic PET studies is compartment models, in which the tracer and its metabolites are confined to a few well-mixed compartments. We examine whether the standard model is suitable for modern PET data or whether theories including more physiologic realism can advance the interpretation of dynamic PET data. A more detailed microvascular theory is developed for intravascular tracers in single-capillary and multiple-capillary systems. The microvascular models, which account for concentration gradients in capillaries, are validated and compared with the standard model in a pig liver study. Methods: Eight pigs underwent a 5-min dynamic PET study after O-15-carbon monoxide inhalation. Throughout each experiment, hepatic arterial blood and portal venous blood were sampled, and flow was measured with transit-time flow meters. The hepatic dual-inlet concentration was calculated as the flow-weighted inlet concentration. Dynamic PET data were analyzed with a traditional single-compartment model and 2 microvascular models. Results: Microvascular models provided a better fit of the tissue activity of an intravascular tracer than did the compartment model. In particular, the early dynamic phase after a tracer bolus injection was much improved. The regional hepatic blood flow estimates provided by the microvascular models (1.3 +/- 0.3 mL min(-1) mL(-1) for the single-capillary model and 1.14 +/- 0.14 min(-1) mL(-1) for the multiple-capillary model) (mean +/- SEM mL of blood min(-1) mL of liver tissue(-1)) were in agreement with the total blood flow measured by flow meters and normalized to liver weight (1.03 +/- 0.12 mL min(-1) mL(-1)). Conclusion: Compared with the standard compartment model, the 2 microvascular models provide a superior description of tissue activity after an intravascular tracer bolus injection. The microvascular models include only parameters with a clear-cut physiologic interpretation and are applicable to capillary beds in any organ. In this study, the microvascular models were validated for the liver and provided quantitative regional flow estimates in agreement with flow measurements.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gateway technology is a powerful system for converting a single entry vector into a wide variety of expression vectors. We expressed recombinant influenza matrix protein M1 (FMP), a potent antigen for cytotoxic T cells, using the Gateway vector pET-DEST42 containing the FMP cDNA, and purified the expressed FMP as a single 32 kDa recombinant protein. N-terminal and internal protein sequencing, however, showed that the recombinant FMP contained an extra 10 amino acids fused to the N-terminal of native FMP. Further investigation of the DNA sequence adjacent to the 5'-FMP cDNA indicated that the TTG in the attB1 site (30bp upstream of the ATG in the 5'-FMP cDNA) behaved as a dominant translation start site, resulting in a 10 amino acid extension of the recombinant FMP. Thus, it is possible that recombinant proteins produced by this Gateway vector contain unexpected vector-derived peptides, which may affect experimental outcomes. (c) 2006 Elsevier Inc. All rights reserved.